Siemens SITRANS LCS100 Operating Instructions Manual page 28

Capacitance switches
Table of Contents

Advertisement

Operating
6.1 Operating elements (LEDs)
Yellow
White
Yellow +
White
See also
Advanced calibration (Page 32)
28
ON
OFF
Blinks for a few times,
then stops blinking
ON
OFF
Blinks fast (twice per
second)
Both LEDs blink
5 times, then
stop blinking
Out 1 activated
Out 1 idle
The number of blinks indicates the position of the
potentiometer after it was turned.
Unit indicates covered
Capacitance on probe
> set switchpoint
Unit indicates uncovered
Capacitance on probe
< set switchpoint
Diagnostics has indicated a failure
Blinking happens when the potentiometer is turned.
The potentiometer is not valid. Calibration
by IO-Link is set.