To Cancel Sleep Mode; Time; To Change Control Panel Address (If More Than One Control Panel Is Used) - SystemAir SAVE VTC 200-1 User Manual

Table of Contents

Advertisement

Off
(Minimum)
The fan can be
Fan speed – 25%
set to Off by
activating
Manual Fan
Stop function in
Service menu.
Note:
• Minimum and Maximum airflow can only be activated by a signal from an external source.
• Auto mode or Manual Fan Stop function can be enabled using the SAVE TOUCH control panel or a
mobile application.
• It is not recommended to set fan to Off in standard households. If manual fan stop is activated, the unit
should be provided with dampers in exhaust and fresh air ducts to avoid cold draught and risk of
condensation when the unit has been stopped.
3.1.3

To cancel sleep mode

Press any button to cancel the sleep mode. SAVE LIGHT returns to the sleep mode after 3 minutes of inactivity.
All control panel lights are off during sleep mode. The sleep mode is active from 9:00 PM to 7:00 AM (based on time of
the air handling unit).
3.1.4
To reset the filter change time
Push and hold
and
3.1.5

To change control panel address (if more than one control panel is used)

If more than one SAVE LIGHT control panel is used, the address of other control panels must be changed.
Each control panel must have it's own unique address number. No control panel should have the same address value to
function properly.
1. Push and hold
button for 10 seconds to see a current control panel address value.
2. Press
button to increase and
Address value can be changed from 6 to 10, default value is 10.
Address value
Indication
6
Low airflow LED is on
7
Normal airflow LEDs are on
8
High airflow LEDs are on
9
Refresh mode LEDs are on
10
All LEDs are on
398086 | v1.1
Low
Normal
Fan speed – 45%
buttons for 3 seconds to reset the filter timer (filter change LED will turn off).
button decrease the value.
Refresh
High
(Maximum)
Fan speed – 70%
Sets speed of
both supply and
extract air fans
to Maximum
levels to replace
indoor air with a
fresh air in a
short period of

time.

The unit returns
to previously
active mode
after 1 hour
when in the
Refresh mode.
Operation |
3
Auto — flashing
slowly
Automatic
airflow control.
Available only
when Week
Schedule,
Demand
Control
functions are
active or Fan
Control setting
is set to
External.

Advertisement

Table of Contents
loading

Table of Contents