To Select A Different Filter Kit; To Clean The Heat Exchanger; Duct System Maintenance; Cleaning Extract Louvres And Supply Air Diffusers - SystemAir SAVE VTC 200-1 User Manual

Table of Contents

Advertisement

4.4.2

To select a different filter kit

Standard filters are designed for good outdoor air quality. It is possible to se-
lect and order filter kits for poorer air quality environment.
To change filter kit type
1. Touch Select different filter kit button in the alarm menu.
Alternatively, go to Filter menu (3.2.2 Home screen overview, page 4,
pos. E).
2. Select filter kit from the list.
3. Touch OK button.
4.5

To clean the heat exchanger

Danger
• Make sure that the Mains supply to the unit is disconnected before performing any maintenance or
electrical work!
Warning
• Beware of sharp edges during mounting and maintenance. Use protective gloves.
Even if the required maintenance is carried out, dust will
build up in the exchanger block. It is therefore of vital im-
portance for the upkeep of a high efficiency that the ex-
changer block is removed from the unit and cleaned
periodically as described below. Clean the heat exchanger
at least every 3 years or when required.
1. Stop the unit by disconnecting the mains.
2. Open the front hatch. See chapter 4.2.
3. Pull out the exchanger using the strap at the front.
4. Gently vacuum the heat exchanger.
5. Remount the heat exchanger.
6. Close and lock the front hatch and connect the unit to
mains.
4.6

Duct System Maintenance

4.6.1

Cleaning extract louvres and supply air diffusers

The system supplies fresh air to your home and extracts the used indoor air via the duct system and diffusers/louvres.
Diffusers and louvres are mounted in ceilings/walls in bedrooms, living room, wet rooms, WC etc. Remove diffusers
and louvres and wash in hot soapy water as required (diffusers/louvres must not be exchanged). Cleaning of diffusers/
louvres can be done as necessary.