Download Print this page

Adjustments - Southbend PLATINUM Series Installation & Operation Manual

Gas convection ovens
Hide thumbs Also See for PLATINUM Series:

Advertisement

PLATINUM SERIES GAS CONVECTION OVEN
A
DJUSTMENTS
ADJUSTMENTS AND SERVICE WORK MAY BE PERFORMED ONLY BY A QUALIFIED TECHNICIAN WHO IS
EXPERIENCED IN, AND KNOWLEDGEABLE WITH, THE OPERATION OF COMMERCIAL COOKING EQUIPMENT.
HOWEVER, TO ASSURE YOUR CONFIDENCE, CONTACT YOUR AUTHORIZED SERVICE AGENCY FOR RELIABLE
SERVICE, DEPENDABLE ADVICE, GENUINE FACTORY PARTS AND ANY OTHER ASSISTANCE.
Warranty will be void and the manufacturer is relieved of all liability if service work is performed by other than a qualified
technician, or if other than genuine Southbend replacement parts are installed.
L
UBRICATION
The door chains and sprockets have been lubricated at the factory with high temperature "Never Seeze" lubricant. After
each six months of usage, lubricate the door chains and sprockets with the same type of lubricant.
Motor lubrication information can be found on permanent label located on motor.
A
G
DJUSTING
AS
The pressure regulator built into the gas valve is factory set at 4.5" W.C. for natural gas and 10" W.C. for propane gas. To
check the manifold pressure:
1. Turn the unit "OFF".
2. Turn main gas valve to entire unit off.
3. Remove front lower panels and locate 1/8" plug in manifold.
4. Remove plug and install a fitting appropriate to connect a manometer.
5. Turn on main gas to unit.
6. Turn ovens "ON" and wait for burners to light up.
7. If manometer does not read 4.5" W.C. for natural gas, or 10" W.C. for propane gas, adjust regulator on gas valve (if
gas pressure is O.K. go to Step 10.
8. Remove cap from top of regulator on gas valve.
9. With a screwdriver rotate regulator adjustment screw clockwise to increase, or counterclockwise to decrease,
pressure until manometer shows correct reading.
10. Repeat steps 1 and 2. ( turn the gas and unit off)
11. Remove manometer fitting and replace plug in manifold.
12. Repeat step 5 and 6 and check the manifold plug for leaks.
13. Replace lower front panels.
P
R
RESSURE
EGULATOR
INSTALLATION AND OPERATION MANUAL 1409003 REV 0 (02/24)
WARNING
NOTICE
A
DJUSTMENTS
PAGE 41 OF 54

Advertisement