Download Print this page

Adjustments - Southbend PLATINUM PCHG30S/T Installation & Operation Manual

Half-size gas convection ovens

Advertisement

PLATINUM SERIES HALF-SIZE GAS CONVECTION OVENS

Adjustments

ADJUSTMENTS AND SERVICE WORK MAY BE PERFORMED ONLY BY A QUALIFIED TECHNICIAN WHO
IS EXPERIENCED IN, AND KNOWLEDGEABLE WITH, THE OPERATION OF COMMERCIAL COOKING
EQUIPMENT. HOWEVER, TO ASSURE YOUR CONFIDENCE, CONTACT YOUR AUTHORIZED SERVICE
AGENCY FOR RELIABLE SERVICE, DEPENDABLE ADVICE, GENUINE FACTORY PARTS OR ANY OTHER
ASSISTANCE.
Warranty will be void and the manufacturer is relieved of all liability if service work is performed by other
than a qualified technician, or if other than genuine Southbend replacement parts are installed.
Lubrication
The door chains and sprockets have been lubricated at the factory with high temperature "Never Seeze" lubricant. After
each six months of usage, lubricate the door chains and sprockets with the same type of lubricant.
Motor lubrication information can be found on permanent label located on motor.
Casters are provided with a Zerk fitting for proper lubrication when required.
Adjusting Gas Pressure Regulator
The pressure regulator is buiolt into the gas valve is factory set at 4.5" W.C. for natural gas and 10" W.C. for propane gas.
To check the manifold pressure:
1. Turn the unit "OFF".
2. Turn main gas valve to entire unit off.
3. Remove front lower panels and locate 1/8" plug in manifold.
4. Remove plug and install a fitting appropriate to connect a manometer.
5. Turn on main gas to unit.
6. Turn ovens "ON" and wait for burners to light up.
7. If manometer does not read 4.5" W.C. for natural gas, or 10" W.C. for propane gas, adjust regulator on gas valve (if
gas pressure is O.K. go to Step 10.
8. Remove cap from top of regulator on gas valve.
9. With a screwdriver rotate regulator adjustment screw clockwise to increase, or counterclockwise to decrease,
pressure until manometer shows correct reading.
10. Repeat steps 1 and 2. ( turn the gas and unit off)
11. Remove manometer fitting and replace plug in manifold.
12. Repeat step 5 and 6 and check the manifold plug for leaks.
13. Replace lower front panels.