Figure 60
1. Hydraulic strainer
5. Reinstall strainer.
6. Reinstall hydraulic hose and 90 degree fitting to
strainer in same orientation.
7. Reinstall and tighten drain plug.
8. Fill reservoir with approximately 7.5 qt. of Dexron
IIl ATF. Refer to Checking Hydraulic Fluid.

Emergency Box Raising

(without starting engine)
The box can be raised in an emergency by cranking
starter or by jumping hydraulic system.
Starter Method
• Crank starter while holding lift lever in the raise
position. Run starter for 15 seconds then wait 60
seconds before engaging starter again.
• If engine will not crank, the load and box
(attachment) must be removed to service engine or
transaxle.
• Back another vehicle up to the rear of the disabled
vehicle.
Jumping Hydraulic System
Before servicing or making adjustments to the
machine, stop engine, set parking brake and
remove key from the switch. Any load material
must be removed from bed or other attachment
before working under raised bed. Never work
under a raised bed without positioning safety
support on a fully installed cylinder rod.
Note: Two hydraulic hoses, each with a male and
female quick coupler, that fit the vehicle couplers are
required to perform this operation.
• Back another vehicle up to the rear of the disabled
vehicle.
Important: The vehicles hydraulic system uses
Dexron IIl ATF. To avoid system contamination,
make sure vehicle used to jump hydraulic system
uses an equivalent fluid.
• On both vehicles, disconnect the two quick coupler
hoses from the hoses secured to the coupler bracket
(Figure 61).
1. Quick coupler hoses
• On the disabled vehicle, connect the two jumper
hoses to the hoses that were disconnected
(Figure 62). Cap unused fittings.