Install The Alkaline; En18 - Panasonic AlCare TK-AS500 Operating Instructions Manual

Alkaline ionizer
Table of Contents

Advertisement

Installation 4
1
Choose a stable,
level surface.
17 cm or more
2
Extend the power cord and hose in the manner
that best suits the location where the unit is installed.
z Do not flatten or bend the cord or hose.
When extending the cord and
hose from the right
Wedge the hoses
into this cutout
3
Attach the suction cup on the bottom surface of the main unit.
4
Fix the main unit on the installation surface using the suction cup.
(to prevent overturning)
Mounting plate (supplied accessory)
When moving the product for maintenance, etc., incline the main unit, insert a chopstick or
z
similar item into the end of the suction cup, and remove the suction cup.

EN18

Install the Alkaline Ionizer
6
9.5 cm
or more
Front panel
of the main unit
When drawing out the cord and hoses from the left side, rotate the
water supply hose counterclockwise, and insert it to the cutout.
Suction cup
(supplied accessory)
Screw it in until it
z
stops lightly.
Main unit
30 mm
7
5
8
Bottom of the unit
Drain hose
Water supply hose
Power cord
Condensation water
outlet (P. EN40)
Wipe off dirt and moisture on the installation
z
position sufficiently.
If the suction cup cannot be directly
z
attached, remove the suction cup mount
of the mounting plate, and attach it on the
installation surface. Then, attach the suction
cup on the mounting plate.
Gasket
When extending the cord and
hose from the left
Front panel
of the main unit
9

Advertisement