Technical Specification

Cooking Hob
Cooking Zones
Supply Voltage
Installed Electric Power
Product Size L×W×H(mm)
Building-in Dimensions
A×B (mm)
Weight and Dimensions are approximate. Because we continually strive to
improve our products we may change specifications and designs without prior
notice.
Installation

Selection of installation equipment

Cut out the work surface according to the sizes shown in the drawing.
For the purpose of installation and use, a minimum of 5 cm space shall be
preserved around the hole.
Be sure the thickness of the work surface is at least 30mm. Please select
heat-resistant work surface material to avoid larger deformation caused by the
heat radiation from the hotplate. As shown below:
CIS633DTT/1
3 Zones
220-240V~, 50-60Hz
2.5kw:2250-2750W or
3.0 kw:2700-3300W or
4.5kw:4050-4950W or
5.5kw:4950-6050W or
6.9kw:5500-6900W
590X520X60
560X490
EN-23
L(mm)
W(mm)
H(mm)
D(mm)
590
520
60
56
Under any circumstances, make sure the Induction cooker hob is well
and the air inlet and outlet are not blocked. Ensure the Induction cooker hob is in
good work state. As shown below
Note: The safety distance between the
the
hotplate should be at least
A(mm)
B(mm)
C(
mm)
D
760
50 mini
20 mini
Air intake
Before you install the hob, make sure that
the work surface is square and level, and no structural members interfere with
space requirements
the work surface is made of a heat
if the hob is installed above an oven, the oven has a built
the installation will comply with all clearance requirements and applicable
standards and regulations
a suitable isolating switch providing full disconnection from the mains p
supply is incorporated in
the permanent wiring, mounted and positioned to
comply with the local wiring rules and regulations.
A(mm)
B(mm)
X(mm)
560
490
50 mini
+5
+5
hotplate and the cupboard above
76
0
mm.
E
Air exit 5mm
-
resistant material
-
in cooling fan
4
EN
-2
ventilated
ower