Full Gauge Controls TC-900E Log Quick Start Manual page 4

Digital controller for freezing systems with defrost scheduling and internal datalogger

Advertisement

6.5 Table of parameters
Fun
[,F00]
Controller's operating mode
[,F01]
Defrost by hour programming
[,F02]
Control differential (normal hysteresis)
[,F03]
Minimum setpoint allowed to the end user
[,F04]
Maximum setpoint allowed to the end user
[,F05]
Startup delay (power up)
[,F06]
Low room temperature alarm (S1)
[,F07]
High room temperature alarm (S1)
[,F08]
Time in refrigeration (interval between defrosts)
[,F09]
Minimum compressor on time
[,F10]
Minimum compressor off time
[,F11]
Compressor state with a disconnected or faulty room sensor (S1)
[,F12]
Defrost at instrument startup
[,F13]
Evaporator temperature (S2 / S3) to determine the end of defrost
[,F14]
Maximum defrost time
[,F15]
Fan on during defrost
[,F16]
Defrost type
[,F17]
Temperature indication (S1) locked during defrost
[,F18]
Draining time (defrost water dripping)
[,F19]
Evaporator temperature (S2 / S3) for the fan to return after draining
[,F20]
Maximum time for the fan to return after draining (fan-delay)
[,F21]
Fan operating mode during refrigeration
[,F22]
Fan stop due to high temperature in the evaporator
[,F23]
Room temperature indication offset S1
[,F24]
Address of the instrument in the RS-485 network
Defrost schedule menu (displayed if F01=2)
[,F25]
Number of defrosts per day (Monday to Friday)
[,F26]
Preferred time to start defrosting (Monday to Friday)
[,F27]
Number of defrosts per day (Saturday)
[,F28]
Preferred time to start defrosting (Saturday)
[,F29]
Number of defrosts per day (Sunday)
[,F30]
Preferred time to start defrosting (Sunday)
Advanced function menu (displayed if F00=1)
Fun
[,F31]
Normal setpoint
[,F32]
Economic setpoint (SPE)
[,F33]
Economic setpoint control differential (hysteresis)
[,F34]
Door closed time to operate in economy mode
[,F35]
Temperature difference (S3-S1) below which the economic setpoint is activated
[,F36]
Temperature difference (S3-S1) below which the normal setpoint is activated
[,F37]
Maximum time on power-saving mode
[,F38]
Temperature limit for Fast Freezing
[,F39]
Maximum Fast Freezing time
[,F40]
Fan on time
[,F41]
Fan off time
[,F42]
Compressor on time in case of S1 fault
[,F43]
Compressor off time in case of S1 fault
[,F44]
Time to collect the gas before starting the defrost
[,F45]
Condition to start the defrost (0= time / 1= temperature)
[,F46]
Maximum open door time for instantaneous defrost
[,F47]
Evaporator temperature (S2 / S3) to start defrosting
[,F48]
Door open time to switch off the fan
[,F49]
Door open time to switch off the control outputs
[,F50]
Maximum condenser temperature (S3) to switch off the control outputs
[,F51]
Control differential for the maximum condenser temperature (hysteresis)
[,F52]
Compressor on time without reaching the setpoint to switch off the control outputs
[,F53]
Room temperature alarm delay
[,F54]
Condenser high temperature alarm (S3)
[,F55]
Open door time for the alarm to go on
[,F56]
Enable buzzer (0-OFF/1-ON)
[,F57]
Function of the input 1 / sensor S3
[,F58]
Function of the digital input 2
[,F59]
Evaporator temperature indication offset S2
[,F60]
S3 sensor temperature indication offset
[,F61]
Intensity of the digital filter applied to sensor (0-deactivated)
[,F62]
Function lock
[,F63]
Time for functions lockdown
[,F64]
Control functions shutdown
[,F65]
Operating mode of the room temperature alarms (S1)
[,F66]
Maximum operating time of the COMP output for maintenance
[,F67]
Time to confirm a low evaporator (S2 / S3) temperature to start defrosting (if F45=1)
[,F68]
Time to confirm high pressure event
[,F69]
Time to confirm low pressure event
[,F70]
Time to ignore measurement of low pressure at start up
[,F71]
Delay time to return to control after a high pressure event
[,F72]
Delay time to return to control after a low pressure event
Description
Description
CELSIUS (°C)
FAHRENHEIT (°F)
Min
Max
Unit
Default
Min
-
0
1
0
0
-
0
2
0
0
0.1
20
°C
2
1
-50
105
°C
-50
-58
-50
105
°C
105
-58
0(NO)
0(NO)
0(NO)
30
min.
-50
105
°C
-50
-58
-50
105
°C
105
-58
1
999
min.
240
1
sec.
0(NO)
0(NO)
9999
0
sec.
0(NO)
0(NO)
9999
0
-
0
2
1
0
-
0(NO)
1(YES)
0(NO)
0(NO)
-50
105
°C
30
-58
0(NO)
0(NO)
90
min.
30
0(OFF)
1(ON)
-
0(OFF)
0(OFF)
-
0
1
0
0
-1(NO)
99
-1(NO)
-1(NO)
min.
0(NO)
0(NO)
99
min.
1
-50
105
°C
20
-58
0(NO)
0(NO)
30
min.
1
-
0
7
4
0
-50
105
°C
50
-58
-50
50
°C
0
-90
-
1
247
1
1
-
1
12
4
1
-
00:00
23:50
06:00
00:00
-
1
12
4
1
-
00:00
23:50
06:00
00:00
-
1
12
4
1
-
00:00
23:50
06:00
00:00
CELSIUS (°C)
FAHRENHEIT (°F)
Min
Max
Unit
Default
Min
-50
105
°C
-15
-58
-50
105
°C
-10
-58
0.1
20
°C
2
1
0(NO)
0(NO)
0(NO)
999
min.
0.1
20
°C
2
1
0.1
20
°C
5
1
0(NO)
100(tOFF)
0(NO)
0(NO)
h.
-50
105
°C
-25
-58
0(NO)
0(NO)
0(NO)
999
min.
1
99
min.
2
1
1
99
min.
8
1
0
999
min.
0
0
0
999
min.
0
0
0(NO)
0(NO)
0(NO)
999
min.
0
-
0
0
1
0(NO)
0(NO)
0(NO)
999
min.
-50
105
°C
-50
-58
-1(NO)
-1(NO)
-1(NO)
999
min.
0(NO)
0(NO)
0(NO)
999
min.
0(NO)
32(NO)
105
°C
55
0.1
20
°C
5
1
0(NO)
0(NO)
0(NO)
999
min.
0(NO)
0(NO)
0(NO)
999
min.
0
105
°C
45
32
0(NO)
0(NO)
0(NO)
999
min.
0(OFF)
1(ON)
-
0(OFF)
0(OFF)
0(OFF)
-
0(OFF) 0(OFF)
17
0(OFF)
-
0(OFF) 0(OFF)
14
-50.1(OFF)
50
°C
0
-90(OFF)
-50
50
°C
0
-90
-
0
9
0
0
-
0
2
0
0
sec.
15
60
15
15
0(NO)
-
0(NO)
0(NO)
4
-
0
1
1
0
0(NO)
9999
0(NO)
0(NO)
h.
0
90
min.
0
0
sec.
0
60
5
0
sec.
0
180
20
0
sec.
30
600
60
30
1
10
min.
3
1
1
10
min.
3
1
*The minimum and maximum values depend on
the values configured in [,F03]and[,F04].
Unit
Default
Max
-
1
0
-
2
0
36
°F
3
221
-58
°F
221
221
°F
0(NO)
30
min.
221
°F
-58
221
°F
221
999
min.
240
sec.
9999
0
sec.
9999
0
-
2
1
-
1(YES)
0(NO)
221
°F
86
90
min.
30
1(ON)
-
0(OFF)
-
1
0
99
-1(NO)
min.
99
min.
1
221
°F
68
30
min.
1
-
7
4
221
°F
122
90
°F
0
-
247
1
-
12
4
-
23:50
06:00
-
12
4
-
23:50
06:00
-
12
4
-
23:50
06:00
Max
Unit
Default
5
221
°F
221
°F
14
36
°F
3
0(NO)
999
min.
36
°F
3
36
°F
9
100(tOFF)
0(NO)
h.
221
°F
-13
0(NO)
999
min.
99
min.
2
99
min.
8
999
min.
0
999
min.
0
0(NO)
999
min.
-
0
1
0(NO)
999
min.
221
°F
-58
-1(NO)
999
min.
0(NO)
999
min.
221
°F
131
36
°F
9
0(NO)
999
min.
0(NO)
999
min.
221
°F
113
0(NO)
999
min.
1(ON)
-
0(OFF)
-
0(OFF)
17
-
0(OFF)
14
90
°F
0
90
°F
0
-
9
0
-
2
0
sec.
60
15
-
0(NO)
4
-
1
1
9999
0(NO)
h.
90
min.
0
sec.
60
5
sec.
180
20
sec.
600
60
10
min.
3
10
min.
3