1. DESCRIPTION
e
The TC970
Log
and TC970
kkkkkkk
refrigeration of freezers, beverage displays, islands and refrigerated counters.
These controllers can activate the refrigeration, defrost, fan and lighting system, and have up to two
digital inputs and two main sensors, one for room temperature and another that, fized to the evaporator,
controls the end of the defrost and the return of the fans. They also allow the inclusion of a third sensor,
which can be used to activate the economic setpoint, control the condenser or in the second evaporator
and a fourth sensor for various monitoring.
The
EHIgfM
line includes the control of VCC - Variable Capacity Compressors and VSF - Variable
Speed Fans. The
SadSBI
controllers provide a series of benefits to the cooling system, such as:
reduced energy consumption, less temperature fluctuation, greater speed in reaching the desired
temperature. From the configuration of its parameters it is possible to make the controller compatible
with the main brands of variable compressors on the market. For better use of energy, ventilation can be
controlled during the compressor off cycle and use Smooth Defrost, a defrosting technique that reduces
the final temperature of the electrical resistance and the amount of heat emitted.
The room temperature control has a normal setpoint and an economy setpoint, in addition to the fast
freezing functionality, alarm functions and specific keys to activate / deactivate the economy mode and
turn the lamp on/off.
They have a serial communication output for integration with Sitrad, an internal real-time clock that
allows the programming of defrost and lighting events, an intelligent function blocking system, an
internal buzzer, control of external pressure switches, an hour meter for compressor maintenance,
digital filter to simulate a moment of mass in the room temperature sensor, shutdown mode of control
functions and internal memory (datalogger) for storing the temperature value in periods of time
determined by the user, temperature variation and the output states. They also allow the monitoring of
HACCP - Hazard Analysis and Critical Control Points through records in the memory of the temperature
alarm, open door and power failure controllers.
2. SAFETY RECOMMENDATIONS
- Make sure you know the correct way to install the controller;
- Make sure that the power supply is turned off and that it is not going to turn on during the installation of
the controller;
- Read this manual before installing and using the controller;
- Use appropriate Personal Protective Equipment (PPE);
- Where it will be used in areas subject to splashing water, such as refrigerated counters, install the
protective film that comes with the controller;
- For protection under more critical conditions, we recommend the Ecase cover, which we offer as an
options (sold separately) ;
- The installation procedures must be carried out by a competent engineer, with regard to current
regulations.
3. APPLICATIONS
- Beverage displays;
- Frozen counters;
- Chambers;
- Refrigerated trucks.
4. TECHNICAL SPECIFICATIONS
Power Supply
TC-970E Log + Eco Faston: 90~240Vac 10%(*) (50/60Hz)
Control temperature
Operating temperature
Temperature resolution
Average consumption
Clock (RTC)
Digital output
Frequency output
Analog output
Operating humidity
Protection degree
Maximum Sizes (mm)
Cutout dimensions (mm)
Output capacity
COMP
DEFR
FAN
AUX
(*) Permissible variation in relation to the rated voltage
TC-970
e
TC-970
DIGITAL FREEZING CONTROLLER
VCC
Quick
Variable
Switch Off
compressor
coupling
Control
connection
Functions
e
Log
Faston are eletronic controllers for
+609 gE
TC-970E Log + Eco: 90~240Vac 10%(*) (50/60Hz)
±
TC-970EL Log + Eco: 12 or 24Vac/dc 10%(*)
±
TC-970EL + Eco Faston: 12 or 24Vac/dc 10%(*)
-50 to 105°C / -58 to 221°F
-20 to 60°C / -4 to 140°F
0,1°C / 0,1°F
Energy backup: CR1220 battery
Time keeping for up to 10 years
Accuracy: ± 6 minutes/year
Configurable dry contact type
10Vcc (± 10%) 50mA max.
0...300Hz (duty-cycle = 50%)
0~10Vdc (10 mA max.)
10 a 90% UR (without condensation)
IP 65 (front)
76 x 34 x 97 mm / 2,99" x 1,33" x 3,82" (WxHxD)
71
±0,5 mm(2,79"±0,02") x 29±
0,5 mm(1,14" 0,02")
120-240 Vac, 12A Resistive, 100k cycles
120-240Vac, 8A General Use, 100k cycles
240 Vac, 1HP, 100k cycles
120 Vac, 1/2HP, 100k cycles
120-240 Vac, 5A Resistive
240 Vac, 1/8 HP
120 Vac, 1/10 HP
240 Vac, 1/8 HP
120 Vac, 1/10 HP
120-240 Vac 5W General Use
e
Log
Log
Faston
IP 65
FRONT
HACCP
Programming
Protection
Function
in Series
degree
5. INDICATIONS AND KEYS
LED indicator for the fan
LED indicator for the
compressor outlet
Menu Access
Key
Set Key
6. INSTALLATION - PANEL AND ELECTRICAL CONNECTIONS
71
± 0,5
mm
Cutout dimensions to
fix the instrument
Panel (Front View)
ATTENTION
FOR INSTALLATIONS THAT REQUIRE LIQUID SEALING, THE CUT OUT FOR INSTALLING THE CONTROLLER MUST BE A
MAXIMUM OF 70.5x29mm. THE SIDE LOCKS MUST BE FIXED IN A WAY THAT IT PRESSES THE RUBBER SEAL AVOIDING
INFILTRATION BETWEEN THE CUT-OUT AND THE CONTROLLER.
7. WIRING DIAGRAM
Image I - 90~240Vac Connection
S1
S2
D1/S3
8
9
10
13
11
12
3
1
2
4
5
6
-
-
+
+
VCC
VSF
A
B
COMP
FAN
SITRAD
FREQ / 0~10V
0~10V
+
+
Image II - 12 Vac/dc Connection
S1
S2
D1/S3
±
4VA
8
9
10
11
12
13
1
2
3
4
5
6
-
-
+
+
VCC
VSF
A
B
COMP
FAN
SITRAD
FREQ / 0~10V
0~10V
Image III - 24 Vac/dc Connection
S1
S2
D1/S3
±
8
9
10
11
12
13
1
2
3
4
5
6
-
-
+
+
VCC
VSF
B
A
COMP
FAN
SITRAD
FREQ / 0~10V
0~10V
The S1 sensor must be in the environment.
The S2 sensor must be fixed to the evaporator using a metal clamp .
To the terminal
Key:
of the connection block
LOG
Monitoring
Fast
Datalogger
System
Freezing
LED indicator for defrosting
LED indicator for the auxiliary outlet
HACCP indication LED
!
A
e
Log
TC-970
D2/S4
14
15
15
16
16
17
18
18
19
19
20
20
21
21
7
A
AUX
DEFR
FAN
COMP
D2/S4
14
15
15
16
16
17
18
18
19
19
20
20
21
21
7
A
AUX
DEFR
FAN
COMP
12 Vac/dc
D2/S4
14
15
15
16
16
17
18
18
19
19
20
20
21
21
7
A
AUX
DEFR
FAN
COMP
24 Vac/dc
evolution
e Lo g
e Lo g
T
T
c
c
970
970
LED indication for the unit of temperature
Up Key
Down Key
Panel
(Side View)
Electric power
supply
90~240Vac
Power supply
Power supply

Advertisement

loading

Summary of Contents for Full Gauge Controls EVOLUTION TC-970E Log+ECO

  • Page 1 evolution TC-970 TC-970 Faston DIGITAL FREEZING CONTROLLER IP 65 FRONT Have this manual in the palm of HACCP Monitoring Quick Variable Variable Switch Off Programming Protection Fast Datalogger Function your hand through the FG Finder System speed fan compressor Freezing e Lo g e Lo g coupling...
  • Page 2: Connecting The Temperature Sensors

    9. OPERATIONS NEW CONNECTION SYSTEM (QUICK COUPLING): 9.1 Quick Access Menu Map PLUGABLE AND QUICK PUSH-IN Press the key (short press) to navigate through the menu functions. Each press will display the next function in the list. To confirm press the (short press).
  • Page 3 9.3 Basic operation 9.3.9 View current time and dates By briefly pressing the /key (short press) you can view the date and time set on the controller. The 9.3.1 Desired Temperature Adjustment (setpoint) current day ([,--d]),month ([,--m]), year ([,--y]), day of the week ([day-]), hour and To enter the setpoint adjustment menu, press / for 2 seconds.
  • Page 4: Access Code

    Digital input alarm [AlIn] 9.4 Advanced Operations When the open door alarm is enabled and activated, a[AlIn]recorded will be made. In this case, the 9.4.1 Access to the main menu information stored is: date and time of the stard of the alarm, duration of the alarm and maximum The main menu can be accessed via the quick menu [Func] option or by pressing <...
  • Page 5 Note 1: To return to a previous menu level, keep the / pressed. 9.4.9 Control PID Note 2: The alarm duration time and the maximum measured temperature can be updated while the The PID controller is made up of a combination of three control actions: Proportional action (P), Integral alarm is ocurring.
  • Page 6 FAHRENHEIT (°F) CELSIUS (°C) Description Unit Standard Unit Standard [,f18] Defrost type [,F19] Condition for starting defrosting 0(Off) 0(Off) [,F20] Interval between defrosts (cooling) if [,F19] = 1 or maximum time without defrosts (cool.) if [,F19] = 2, 3 or 4 minutes minutes 9999...
  • Page 7 FAHRENHEIT (°F) CELSIUS (°C) Description Unit Standard Unit Standard [,F89] AUX output mode [,F90] Time to turn on the AUX output if [,F89] = 5 (Monday to friday) 00:00 hh:mm 00:00 00:00 hh:mm 00:00 23:59 23:59 [,F91] Time to turn off the AUX output if [,F89] = 5 (Monday to friday) hh:mm hh:mm 00:00...
  • Page 8 [F00] - Controller operating mode: F19 - Condition for starting defrosting: [,,,0] – Refrigeration / Cooling [OFF,] – No automatic defrosting, only manual defrosting; The compressor turns off when the temperature of sensor S1 (room temperature) is less than or equal [,,,1] –...
  • Page 9 [F41]- Maximum time on defrost (for safety): If F44 = 1 If F44 = 2 This function adjusts the maximum duration of a defrost cycle. If the defrosting is not complete, during Temperature S2 Temperature S1 this period, according to the temperature, a dot will begin flashing in the lower right corner of the display, F52+ indicating that the time set for the defrost has ended by the required temperature has not been reached.
  • Page 10 [F82] - Variable compressor on time after reaching the sepoint: Note 1: When the digital input is configured as a pressure switch contact, it allows turning off the compressor, fan and defrost outputs, displayng the alarm associated with the source input. When the After reaching the temperature setpoint, it is possible to keep the compressor running at a speed pressure switch event clears, the controller returns to the configured initial process.
  • Page 11 [F100] - Temperature alarm validation time: Note 1: Voltage monitoring only applies to low voltage models (12 or 24Vac/dc) TC-970EL Log + Eco or This function serves to inhibit the alarm for a period due to an eventual rise in temperature. TC-970 EL Log + Eco Faston.
  • Page 12 [Aplo] Low pressure alarm (manual alarm required) Extended Panel Full Gauge Controls extended panel allows controllers to be installed in Evolution and Ri lines (the opening [ApHi] High pressure alarm (manual alarm required) must measure 71x29mm for the extended panel to be installed), as the opening does not need to be precise for the device to be properly installed.
  • Page 13: Warranty

    Observe the laws in your area regarding disposal of electronic waste. If in doubt, please contact Full Gauge Controls Products manufactured by Full Gauge Controls, as of May 2005, have a two (02) year warranty, as of the date of the consigned sale, as stated on the invoice. They are guaranteed against manufacturing defects that make them unsuitable or inadequate for their intended use.

This manual is also suitable for:

Evolution tc-970e log+eco faston