13.

Thermistor measurement values

Temperature control is implemented by means of an NTC-thermistor.
The tolerance of the temperature measurement shall be less than +/- 1°C within the range
30-90°C.
Temp, ºC
Resistance, ohm
0
15806
10
9634
20
6046
25
4841
30
3900
40
2579
50
1744
60
1204
70
848
80
609
85
519
In case of an open circuit or < 300 Ω (>120°C) on the thermistor when the heater is on the program
shall precede to next program step.

14. Technical data

Height:
Width:
Depth:
Weight:
Cylinder volume:
Max. load capacity
Spin speed:
Connection:
Heater output:
Water pressure/inlet valve:
Wash drum and liquid compartment:
Outer panels:
Installation:
Water connection:
Drainage:
Protection class:
Water consumption (tested normal
programme)
Water consumption (tested normal
programme)
Electricity consumption, Standby:
- Machine turned off
- Delayed start
- Programme ended
850 mm
595 mm
716 mm
73 kg
60 l
11, 10, 8 kg
1400 rpm max.
1-phase 16 A, 3-phase 10 A
7 kW max.
0.1–1 MPa, 1–10 kp/cm2, 10–100 N/cm2 8 l/min
Stainless steel
Powder-coated and hot-galvanised sheet steel or stainless
steel
Stationary on four adjustable, rubber-clad feet
1.5 m PEX tubing, 3/4"–3/4" or 3/4"–1/2"
1.7 m polypropylene tubing
IP X4
59 litres, 3 rinses (5 kg/6 kg <72 litres, 5 rinses (6 kg) <69
litres, 5 rinses (5 kg)
1.02 kWh (6 kg) 0.95 kWh (5 kg)
<0.3 W
<6.0 W
<3.0 W