Service.manual.WM60
Components and measurement values
Item number
Component
80.658.33
CIM-motor
80.617.06
Värmeelement
2000.W
80.761.02
Thermistor
88.012.63.
Drain.pump.50.Hz
88.012.64.
Drain.pump.60.Hz
80.782.21
Level.Switch
80.762.02
EMC.filter.with.inductor.
50/60.Hz
80.793.24
Inlet.valve
80.798.73
Door.lock
80.773.63
Control.Unit.WM60.3
80.792.89
Control.Unit.WM60.3.FI
80.803.87
Motor.Control.Unit.(MCU)
80.806.02
Control.Unit.WM60.2
Measurement values thermistor
Temp, º C
Temp, º F
0
32
10
50
20
68
25
77
30
85
40
105
50
120
60
140
70
160
80
175
85
185
28
Measurement value
Resistances:
Pin 1-3 stator 3.7 Ω
Pin 1-2 stator 3.6 Ω
Pin 2-3 rotor 3.6 Ω
Pin 4-5 tacho 178 Ω
28,4 Ω
6.1-3.8.k
Ω (at room temperature 20
°F
–.30°C/.86
)
144 Ω.
76 Ω
680 kΩ
3,7 kΩ ± 0,5 kΩ
122 Ω
Resistance, O��m
15806
9634
6046
4841
3900
2579
1744
1204
848
609
519
Comments
The.thermistor.for.temperature.reading.is.
located.between.the.motor.cradle.and.the.
container..The.thermistor.measures.and.
controls.the.water.temperature.that.can.
°F
vary.from.0.to.90°C/.194
..The.element.is.
disconnected.if.the.thermistor.is.short-circuited.
or.disconnected.from.the.program.control.card.
The.drain.pump.is.combined.with.an.integrated.
fine.filter.trap,.which.can.be.cleaned.by.the.
user..If.the.drain.pump.has.run.for.180.seconds.
during.draining,.the.program.stops,.resets.and.
a.fault.code.is.indicated.in.the.display..The.
drain.pumps.capacity.is.20.liters/min.
Electro.mechanical.level.switch.with.two.levels,.
see.wiring.diagram..Indicates.levels.for.door.
opening,.heat.and.overfilling....
The.filter.eliminates.interference.to.and.from.
the.machine.
2.way.inlet.valve.8.litres./.minute
The.door.lock.is.electro.mechanical.and.
equipped.with.a.magnet.