Components and measurement values

Item number
Component
80 655 63
Motor 50 Hz
80 637 33
Motor 60 Hz
80 617 06
Heating Element
2000 W
80 761 02
Thermistor
88 012 63.
Drain pump 50 Hz
88 012 64.
Drain pump 60 Hz
80 782 21
Level Switch
80 616 64
Pressure sensor
80 762 02
EMC filter with induc-
tor 50/60 Hz
80 762 01
Inlet valve
80 616 79
Door lock
80 771 27
Control Unit WM25.1
80 771 28
Control Unit WM25.2
80 771 29
Control Unit WM25.3
Measurement value
Resistances:
Pin 2-3 stator 1.41 Ω
Pin 1-3 stator 0.57 Ω
Pin 4-5 rotor 1.54 Ω
(measured diagonally
across the collector)
Pin 6-7 tacho 135 Ω
Resistances:
Pin 2-3 stator 1.05 Ω
Pin 1-3 stator 0.58 Ω
Pin 4-5 rotor 1.75 Ω
(measured diagonally
across the collector)
Pin 6-7 tacho 135 Ω
28.4 Ω
6.1-3.8 k
Ω (at room tempera-
ture 20 – 30°C)
144 Ω.
76 Ω
0.5 V out from the
sensor (at 0 bar pres-
sure and 230 V mains
voltage, measurement
carried out with the
drain pump running
to ensure 0 level is
reached)
3,7 kΩ ± 0.5 kΩ
122 Ω
Comments
All resistance values have tolerances
of ±8 %.
All resistance values have tolerances
of ±8 %.
The thermistor for temperature reading
is located between the motor cradle
and the container. The thermistor mea-
sures and controls the water tempera-
ture that can vary from 0 to 90°C. The
element is disconnected if the thermis-
tor is short-circuited or disconnected
from the programme control card.
The drain pump is combined with an
integrated fine filter trap, which can be
cleaned by the user. If the drain pump
has run for 180 seconds during drain-
ing, the programme stops, resets and a
trouble code is indicated in the display
(on machines without a display, the
LEDs flash).
See above.
Electro mechanical level switch with
two levels, see wiring diagram. Indica-
tes levels for door opening, heat and
overfilling.
ASKO level sensor type 1166. Controls
intake and level
The filter eliminates interference to and
from the machine.
3 way inlet valve 10 litres / minute
The door lock is electro mechanical
and equipped with a magnet.