Components And Measurement Values - Asko WM80 C Series Service Manual

Washing machines and dryers
Table of Contents

Advertisement

Security fault
The door is open
Thermistor fault
1. Thermistor circuit open
2. Thermistor malfunction
3. The measurement value
for the thermistor is <300
Ω (>120°C)
Temperature fault
The temperature has
increased < 5°C in ten
minutes
The wash cycle should
continue to the next step
of the programme.
Wash motor fault
No signal from the tacho
or MCU.
Pressure fault
Indicated if the level drops
to zero within 30 seconds
of the first rinse.

12. Components and measurement values

Component
CIM motor
Heating element:
2000 W,
1000 W,
2200 W (2 x 2,2kW),
7000 W (2 x 3,5kW)
Thermistor
Drainage pump 50 Hz
Drainage pump 60 Hz
Level switch
EMC filter 50/60 Hz
Inlet valve
Door lock
One-way inlet valve
Motor control
Control unit
Communication unit
Outlet valve
Measurement value
Resistances:
Pins 1-3 stator 3.7 Ω
Pins 1-2 stator 3.6 Ω
Pins 2-3 rotor 3.6 Ω
Pins 4-5 tacho 178 Ω
6.1–3.8 kΩ
(at room temperature
20 –30°C)
144 Ω
76 Ω
680 Ω
3.7 kΩ ± 0.5 kΩ
122 Ω
Close the door
Service action:
Check the thermistor. Replace if necessary.
Service action:
Check the thermistor, heater, wiring and level
system.
Service action:
Check the output signal from the MCU and the wiring
between the motor and the MCU.
Service action:
Check for leaks.
Comment
The thermistor for measuring temperature is
located between the motor cradle and the drum.
The thermistor measures and controls the water
temperature, which can vary from 0 to 92°C. The
heater is disconnected if the thermistor is short-
circuited or disconnected from the programme
control card.
The drainage pump is combined with an
integrated fine filter trap, which can be cleaned by
the user. If the drainage pump has run for 3
minutes during draining, the programme stops
resets and a fault code is indicated on the display.
The pump has a capacity of 20 litres/minute.
Electromechanical level switch with two levels
(see wiring diagram). Used to indicate levels for
door opening, heat and overflow.
The filter eliminates interference to and from
the machine.
Two-way inlet valve, 8 litres/minute
The door lock is electromechanical and
equipped with a magnet.
15