TECHNICAL SPECIFICATIONS
FUNCTIONAL
Operating Power
Ambient Temperature
Process Temperature
Operating Pressure
Accuracy
Dielectric Constant
Output
PERFORMANCE
Measuring Range
Resolution
PHYSICAL
Process Connection
Ingress Protection
Conduit Connections
Electrical Protection
Probe Materials
Enclosure Materials
Seals
Shipping Weight (Head
Unit)
APPROVALS
ATEX MARKINGS
II 1G Ex ia IIB T6...T4 Ga
II 1D Ex ia IIIC T85°C... T110°C Da
T ambient = -30°C...+65°C
TDR180003 Rev. I
24 VDC (12 to 36 VDC)
Ex Version: 24 VDC (12 to 30 VDC)
-22° to 149° F (-30° to 65°C)
-4° to 149°F (-20° to 65°C) with display
-22° to 194°F (-30° to 90°C)
-14 to 232 psi (-1 to16 bar)
±20 mm (±0.75"), if probe length ≥10 m (32 ft):
±0.2% of the probe length
> 2.1
4-20mA, Optional Relay
Flexible Probe: Max of 98.5ft (30 m)
Deadband Top: 13.8" (35cm) if Er < 10 ; 9.84" (25cm) if Er > 10
Deadband Bottom: 14.2" (36 cm)
Counter Weight Diameter: 1.6" (4 cm); length 10.2" (26 cm)
0.04" (1 mm)
1½" NPT
1P67
(2) M20 x 1.5 and (2) ½" NPT
Class III
Flexible 316 Stainless Steel Cable
Aluminum with white epoxy coating
FPM (Viton®), FFKM (Kalrez®), EPDM
4.85 lbs (2.2 kg)
5
www.bindicator.com