6.0 Technical Specifications

Function:
Measuring Range:
Accuracy:
Repeatability:
Dielectric Constant:
Probe Materials:
Operating Pressure:
Flange Temperature:
Electronics Temperature: -22° to 131°F
Connection:
Protection Category:
Power Supply:
Output:
Communication:
Approvals:
Weight:
Materials of
Construction:
Electrical Connection
M16 CONNECTOR
Terminals:
Cable Entries:
Electrical Signal Output
Electrical Connection:
Power Supply:
Current Output:
Environment
Ambient Temperature:
Protection Category to
EN 60529 / IEC 529:
®
BINDICATOR
Level, distance and volume measurement of liquids and solids.
Flexible probe: to 78ft
Deadband:
Top: 15.8in Dieletric < 10
11.8in Dieletric > 10
Deadband: Bottom: 14.25in
Counter Weight Diameter.: 1.575in; length 10.25in
(Weight is tapped with 1/2" - 13 to allow tethering or anchoring)
+/- 0.6in
0.04in
> 2.3
Flexible cable 316SS
232 psi
-22° to 194°F
1.5" MNPT
IP66; Nema 4X
24VDC (18 to 35VDC)
4/20mA current loop into max. of 750 Ohms
HART protocol
CE
Without probe 4.4lbs (2Kgs)
Housing: Aluminium with white epoxy coating
Cable and Weight: 316 SS
Gaskets: Buna N
Max wire size 16AWG (1.5mm)
1 x M16 x 1.5 (with standard cable gland: cable
clamping area =0.137 - 0.315in(3.5-8mm)).
Two wire
18 to 35 VDC
4/20mA
-22° to 131°F
IP66, Nema 4X
Installation, Operation & Maintenance Manual
4

Advertisement

Table of Contents
loading