Dometic FreshJet 7 Lite 48 V Series Operating Manual page 19

Hide thumbs Also See for FreshJet 7 Lite 48 V Series:
Table of Contents

Advertisement

Interval
Regulary
Regulary
Once per year
Inspection/maintenance
Check whether the condensation water drainage channels (1) at the sides of the roof air condi-
tioner are clear and the condensation water is able to escape.
• Clean the filter of the air discharge unit.
2
1
1.
Insert a flat screwdriver or knife into the handle (1) to pull the filters (2) slightly out.
2.
Remove the filters by hand.
3.
Clean the filters with a detergent solution and let them dry.
4.
Slide the dry filters back
• Have the heat exchanger of the roof air conditioner serviced by specialist company.
• Check the seals between the roof air conditioner and the vehicle roof for cracks and other
damage.
• Check whether the fastening bolts are tightened to the correct torque (2.5 Nm
± 0.3 Nm) and adjust if necessary.
Dometic FreshJet 7 Series Lite 48 V   EN
in.Fig. 
on page 19
1
2
19