The switch-to-standby timer is set. The roof air conditioner will be switched to standby at the specified time.
Set the switch-on timer and the switch-to-standby timer as follows:
a) Select the desired air conditioning mode and all required values (for example the temperature).
b) Press the
The
c) Use the + or – button to set the time when the roof air conditioner shall be switched on.
d) Press the
The OFF symbol flashes.
e) Use the + or – button to set the time when the roof air conditioner shall be switched to standby.
f) Press the
The switch-on and switch-to-standby times are set. The roof air conditioner will be switched on for the specified
time period.
To cancel preset timer, press the
The
9.10
Setting the sleep function
The sleep function is only available in Cooling ( ) or Heating ( ) modes.
The sleep function limits the fan speed to a lower level to reduce the noise levels for easier sleeping.
Only for inverter models: The sleep function additionally limits the compressor speed.
To activate the sleep function proceed as follows:
a) Set the required temperature
b) Press the
The symbol
appears in the remote control display. The sleep function is activated.
To deactivate the sleep function, press the
control panel.
The symbol
disappears in the remote control display. The sleep function is deactivated.
9.11
Activating the I feel function
When this function is active, the remote control measures the room temperature and transmits this measurement to
the roof air conditioner every 10 minutes. The roof air conditioner adapts the target value to this measurement. The I
feel function is only active when the temperature range is between +18 °C and +29 °C.
The remote control should not be kept in a part of the room that is considerably warmer or colder than the average
room temperature. It may not, for example, be le in the sun or in front of the roof air conditioner.
When the temperature rises above +29 °C or falls below +18 °C, the I feel function is deactivated. The
flashes three times in the display and then turns off.
1.
Press the button.
The I feel function is activated.
The
symbol appears in the display.
2. Position the remote control so that it points at the IR receiver on the control panel. Otherwise, the values cannot
be transmitted to the roof air conditioner.
14
button three times.
symbol is shown on the remote control display. The ON symbol flashes.
button.
button.
button once.
symbols disappear. Preset values are discarded.
(Setting the temperature
button on the remote control or the
on page 13).
button on the control panel.
or the
button on the remote control or the
button on the
symbol