Modem Power-Up; Selecting Factory Configuration Options - Paradyne 3825Plus User Manual

Zhone comsphere 3825plus modems: user guide
Hide thumbs Also See for 3825Plus:
Table of Contents

Advertisement

COMSPHERE 3825Plus Modem

Modem Power-Up

Once your modem is properly connected to the DTE,
dial or leased lines, and ac outlet, press the modem's rear
panel power switch to the ON position. The modem
begins a power-up self-test in which all front panel LEDs
momentarily light (note that this also occurs on a reset of
the modem), and the Power LED remains ON. The state
of other LEDs depends on your modem's configuration.
See
Table 1-1
in Chapter 1.
On initial power-up, the modem is in Command mode.
To verify that the modem is connected and functioning
properly, enter the following:
TYPE:
AT
PRESS:
Enter (Return)
The screen displays OK.
If the modem does not return OK, refer to
Appendix B, Troubleshooting.
Selecting Factory
Configuration Options
After the modem passes the power-up self-test, it can
be configured for operation using one of the factory preset
configurations.
The purpose of preset configurations is to simplify the
customization your modem.
These factory preset templates contain the most
commonly used configuration options (straps) for
Asynchronous Dial, UNIX Dial, and Cellular
configurations. Your modem is shipped from the factory
with the Async Dial default configuration options stored
in memory. If UNIX Dial, Cellular (Mobile) or Cellular
(PSTN) is more appropriate for your configuration, then
you must change the factory setting as described as
follows.
2-4
If you have already changed
certain configuration options, you
may have lost AT command
control. For example, operating in
Synchronous mode or disabling AT
commands results in an inability to
change configuration options. To
regain AT command control, refer
Recovering AT Commands
to the
section for these procedures.
To change a factory template, perform the following
steps (for more information on changing factory templates
using AT commands, refer to Chapter 4,
and
S-Registers).
Procedure
1. Use the AT&F&W command to load the
appropriate factory configuration to the appropriate
storage area. Enter the following:
TYPE:
AT&Fy&Wn
Where:
y is one of the following Factory
configurations:
0 for Async Dial
3 for UNIX Dial
5 for Cellular (Mobile)
6 for Cellular (PSTN)
(&F5 and &F6 are available only if
ETC is installed.)
and
Where:
n is one of the following storage areas:
0 for Active (Saved)
1 for Customer 1
2 for Customer 2
These three configuration areas are
nonvolatile memory locations.
Active (Saved) contains the most
recently saved changes to any
configuration options. In the event of
power loss, the modem retrieves these
configuration options. Customer 1 and
Customer 2 are user-defined
configuration storage areas.
2. PRESS:
Enter (Return)
January 1999
NOTE
AT Commands
3825-A2-GB30-40

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3825plus

Table of Contents