COMSPHERE 3825Plus Modem
Numbers (1)
Numbers (2)
0
1
2
3
4
5
6
7
8
10
10
11
11
12
12
13
16
14
13
15
14
16
15
*Appears when the Extended Result Codes configuration option is enabled.
**Appears when the Extended Result Codes configuration option is set for Use_DTE_Rate. This displays the DTE data
rate instead of the line rate.
A-2
Result Codes
Word
0
OK
1
CONNECT
2
RING
3
NO CARRIER
4
ERROR
5
CONNECT 1200*
6
NO DIALTONE*
7
BUSY*
8
NO ANSWER*
CONNECT 2400*
CONNECT 4800*
CONNECT 9600*
CONNECT 12000*
CONNECT 14400*
CONNECT 19200**
CONNECT 7200*
Table A-1
(1 of 3)
Command executed
Modem connected to line
Modem receiving a ring voltage from the VF line
Modem lost or does not detect carrier signal, or
does not detect answer tone
Invalid command
Connection at 1200 bps
No dial tone detected
Busy or trunk busy signal detected
No ''quiet" answer (@)
Connection at 2400 bps
Connection at 4800 bps
Connection at 9600 bps
Connection at 12,000 bps
Connection at 14,400 bps
Connection at 19,200 bps
Connection at 7200 bps
January 1999
Description
3825-A2-GB30-40