S14
Asymmetric Rate Mode
Register determines whether VF rates for transmitting and receiving are identical when using V.34 modulation. Enabling
the function permits the two rates to be different.
Register has the following values:
0 = Enable
1 = Disable
The factory setting is Enable.
S18
Test Timeout
Sets the duration (in seconds) for the modem tests. This automatically cancels any test in progress after the time of this
register expires. Any test can be manually canceled by issuing the escape sequence (+++) followed by the &T0
command.
Enter a value from 0–255 seconds. (A value of 0 disables this register.)
The factory setting is Disable (0).
S26
RTS-to-CTS Delay
Sets the length of time (in 10-millisecond increments) the modem waits after receiving RTS before issuing CTS to the
DTE.
Enter a value from 0–255.
The factory setting is 0 milliseconds.
S38
DTR Continuous Repeat
Determines whether automatic dialing of dial backup directory location 1 will be repeated continuously if unsuccessful, or
halted after the first pass.
NOTE: A lockout from redialing occurs after the number of successive failing call attempts specified in national
regulations. Ten successive attempts are permitted in North America.
Register has the following values:
0=Disable
1=Enable
Factory setting is Disable.
S39
Receive Buffer Disconnect Delay
Determines the maximum amount of time the modem can continue to send data in its Receive Buffer to the DTE after the
modem is commanded by the DTE to disconnect, or after the modem detects a line disconnect.
Register has the following values:
0 = Disable (Immediate disconnect)
1 = 1 second
2 = 2 seconds
255 = 255 seconds
3825-A2-GB30-40
Table 4-2
(3 of 10)
3825 Plus S-Registers
January 1999
AT Commands and S-Registers
4-19