Graco 24D829 Instructions-Parts List Manual page 43

Ac hydraulic power pack module
Table of Contents

Advertisement

1
Assemble coupler (202, 212) to specified dimension prior to
mounting motor and pump to housing.
2
Torque to 40 ft-lbs (54 N•m).
3
Torque to 35 ft-lbs (47 N•m).
4
Torque to 70 ft-lbs (95 N•m).
5
Torque to 15 ft-lbs (20 N•m).
6
Torque to 185 in.-lbs (20 N•m).
7
Torque to 62 in.-lbs (7 N•m).
8
Torque to 65 in.-lbs (7.3 N•m).
9
Torque to 10 ft-lbs (13 N•m).
Torque to 40 in.-lbs (4.6 N•m).
10
Torque 1/4 turn past hand tight.
11
Apply PTFE tape on installation end only prior to assembly.
12
210
7
263
209
13
3
225
3A0238G
1
208
12
201
207
+.00
1.68
-.01
13
10
251
19
2 14
250
20
15
234
13
7
231
16
Apply sealant to threads prior to assembly.
13
Apply a light coating of lubricant to seals prior to assembly.
14
Tighten tubing nuts hand tight and then with a wrench. Torque
15
1-1/2 flats.
Directional valves are supplied with o-rings.
16
Route all signal cables through cable ties on the filter side of the
17
power pack.
Route all power wires through cable ties on the filler side of the
18
power pack.
Apply lubricant to contact side of thermal switch harness (250)
19
prior to assembly.
Install roll pin (263) into diverter block (207) for orientation to
20
hydraulic housing (206).
Cables and leads removed for clarity.
21
202
216
2
14
224
228
230
233
16
1
212
+.00
.07
-.01
211
227
12
226
9
14
235
6
226
229
2 14
230
15
216
2 14
Parts
252
232
16
234
7
13
9
14
43