Repair
Remove Hydraulic Power Pack
Shroud
1. Remove four screws from base of shroud.
2. Lift shroud off of hydraulic power pack.
Install Hydraulic Power Pack
Shroud
NOTICE
Do not over-torque any item that threads into the
hydraulic tank (237). This will strip the threads and
require tank replacement.
1. Place shroud on top of hydraulic power pack.
2. Install four screws securing shroud to hydraulic tank.
Remove Hydraulic Power Pack
NOTICE
If any debris falls into the hydraulic tank, the debris
must be removed or machine damage will result.
1. Perform Shutdown procedure, see page 21.
2. Perform Remove Hydraulic Power Pack Shroud
procedure.
3A0238G
3. Disconnect all hydraulic lines from A1, A2, B1, and
B2 fittings at the applicator housing.
B1
A1
F
. 20
IG
4. Disconnect all electrical cables connected to the
motor, directional valves, temperature switch, and
pressure transducer.
5. Disconnect heat exchanger inlet hose (76) and fit-
ting from elbow fitting (249) on hydraulic housing
(206). Disconnect heat exchanger outlet hose (77)
and fitting from elbow fitting (248).
248
F
. 21:Heat Exchanger Inlet and Outlet Hoses
IG
Repair
B2
A2
206
249
76
77
27