Download Print this page

hergom CRAFTSBURY Installation, Use And Maintenance Instructions page 8

Advertisement

If the glass o�en gets dirty, the combus�on temperature
level is low; this indicates the risk of creosote forma�on.
The flue system must be checked at the heater
connec�on and in the chimney's top end. Cold surfaces
tend to create deposits rapidly, that's why it is important
to check the chimney at the top end, as it is
the coldest area, as opposed to the heater connec�on.
The accumulated creosote must be eliminated with a
specific cleaning brush designed for this use.
This is why it is recommended that before each season
of use a professional inspec�on is carried out of all the
system, clean it and repair it, if necessary.
Joints
The joints normally must be changed every 2 or 3 used
seasons, depending on the heater's use. If the sealing of
the door is missing, a new joint ensures an adequate
sealing and improves the heater's opera�ng. Contact
your supplier to provide you with a set of joints for your
heater.
To replace the door joints proceed in the following way:
1.
First take away the old one with a tool or knife �p.
2.
Clean all the joint channels with a wire brush, to
eliminate the cement and fibre residue.
3.
Put the new joint in its without spreading out the
material.
4.
Close the door immediately to put pressure on the
joint in its place and ensure a correct sealing.
The use of the following joints is required:
FRONT DOOR: 1.50 m long, 9,5 mm in diameter. Low
density black cord (Code J38)
GLASS: 1.30 m long 6,35 mm. In diameter (Code J14)
Glass
Do not use the heater with the door glass broken. Do
not knock or slam the front door when shu�ng.
If deemed necessary, you may clean the door glass with
a Hergóm Window Cleaner that is provided byyour
supplier.
Never try to clean the glass when the heater in
opera�ng or the glass is hot.
Most of the par�cles deposited, may be cleaned
following the cleaner's use instruc�ons.
To clean the difficult par�cles, open the door, remove
the arch placed under the top, pull the door upwards
and detach it from the heater.
Place the door on a table or working surface and apply
the cleaning product on the glass le�ng it work during a
few minutes.
Leave the door in a horizontal posi�on, to allow
cleaning product to be�er penetrate the glass surface.
Dry the cleaning product with a so� cloth.
Important: to knock or scratch the glass will deteriorate
its integrity. Do not use blades or metal sponges, or
other abrasive materials as tools to clean the glass.
The door glass is ceramic, manufactured specially for the
use of wood heaters.
Do not use any other glass that is not ceramic
manufactured for the use of these wood heaters. Make
the replacement of the glass through your supplier.
If the door glass breaks it must be replaced immediately.
Contact your supplier to request a glass and necessary
parts for its repair.
Should you replace the glass yourself, use working
gloves and safety glasses.
The procedure to change the glasses and glass joints is
the following:
1.
Open the door,
top,
and pull the door upwards and detach it from
the heater.
2.
Place the door front down horizontal on a flat surface.
3.
Apply penetra�ng oil on the glass cramp screws.
Withdraw the screws and li� the cramps and the
ceramic fibres that may be under them.
4.
Carefully li� the door's damaged glass and throw it
away in the rubbish
8 of 24
remove the arch placed under the
FIG. 6
the

Advertisement

loading