Fujitsu AUUH18LUAS Service Manual page 175

Cassette type
Table of Contents

Advertisement

Sensor ID
Expansion valve (Upstream during
01
060
heating)
01
080
4-way valve output status
01
085
Pressure switch (High pressure)
01
088
Crankcase heater output On/Off
01
089
Base pan heater output On/Off
01
090
Belt heater output On/Off
01
100
Operating current
01
110
Outdoor unit total power-on hours
Compressor total heating operation
01
111
hours
Compressor total cooling operation
01
112
hours
01
113
Compressor total operation hours
Outdoor unit fan 1 total operation
01
114
hours
Outdoor unit fan 2 total operating
01
115
hours
Outdoor low noise input (External
01
145
input)
01
146
Outdoor peak cut (External input)
01
147
Demand response (External input)
01
155
Compressor status (External output)
01
156
Error status (External output)
7-14. Unit status monitoring and the detected value indication
Available Sensor ID
Item
07: Cooling/
- (04-37) -
Unit
05: pls
0: Cooling, 1: Heating
Heating
08: On/Off
0: Off (Close), 1: On (Open)
08: On/Off
0: Off, 1: On
08: On/Off
0: Off, 1: On
08: On/Off
0: Off, 1: On
09: A
11: h
11: h
11: h
11: h
11: h
11: h
00: —
0: Off, 1: On
0: Off
1: Mode 4 (100%)
2: Mode 3 (75%)
00: —
3: Mode 2 (50%)
4: Mode 1 (Forced thermostat off)
0: Normal, 1: DRM1, 2: DRM2, 3:
00: —
DRM3
00: —
0: Off, 1: On
00: —
0: Off, 1: On
Remarks
7. Various control

Advertisement

Table of Contents
loading

Table of Contents