Fujitsu AUUH18LUAS Service Manual page 144

Cassette type
Table of Contents

Advertisement

¢ Model: AOUH24LUAS1
Rotation number of compressor soon after starting is controlled as below.
Rotation number VI
Rotation number V
Rotation number IV
Rotation number III
Rotation number II
Rotation number I
• Normal operation
Rotation
number (rps)
Time (sec)
• Special operation
Rotation
number (rps)
Time (sec)
NOTES:
• Normal operation:
– Cooling and dry mode
• Below 3 hours from the compressor stop and the compressor thermistor ≥ 59°F (15°C)
• After defrost operation
– Other than when the compressor starts for the first time since the breaker turns on
• Special operation:
– Other than the normal operation condition
– →hen the compressor starts for the first time since the breaker turns on
1-4. Rotation number of compressor at normal start-up
Time 1
Time 2
I
II
35
52
1
2
60
140
I
II
35
52
1
2
60
140
- (04-6) -
Time 3
Time 4
Time 5
III
IV
64
71
3
4
170
200
III
IV
64
71
3
4
170
200
Time 6
V
VI
89
97
5
6
350
410
V
VI
89
97
5
6
350
410
1. Rotation number control of compressor