sectional area shall not be less than the specification requirements of the power cord in the
Manual.
(15) The unit shall use special circuit and socket, and be equipped with appropriate leakage protection
switch and circuit breaker (air switch). The circuit breaker shall be full-pole open, with the contact
breaking distance of at least 3 mm.
(16) According to the relevant laws, regulations and electrical standards, special branch leakage
devices shall be installed.
(17) The connection method of the unit and the power cord and the interconnection method of each
independent component shall be subject to the circuit diagram attached to the unit body.
(18) All wiring must use crimping terminals or single-core wires. The direct connection of
multi-stranded wires with the terminal block may cause a spark.
(19) Do not change the internal wiring of the unit at will, otherwise, our company may not assume
relevant legal responsibilities in case of relevant losses.
(20) The model and rating of the fuse shall be subject to the silk screen identification on the
corresponding controller or fuse sleeve.

2.Unit Installation Diagram

3.Dimensional Requirements of Installation Space

(1) The dimensional requirements of installation space of the unit are shown in the figure below.
(2) The installation distance of the unit from the swimming pool shall not exceed 15 m.
(3) The heat pump must be installed at a minimum distance from the pool in compliance with
NFC15-100 (3.5 m from the water for France) or in compliance with installation standards
applicable in other countries.
Fig. 2-1 Unit installation diagram
22