4.Specifications

4.1 Specifications
High-temperature & high-humidity heating:
ambient temperature: 27°C/80%, 26°C water
inlet
Medium-temperature & medium-humidity
heating:
ambient temperature: 15°C/70%, 26°C water
inlet
Cooling
ambient temperature: 35°C/-, 30°C water
inlet
Maximum power
Maximum current
Nominal Water flow
Water resistance (Max)
Dimension(W×D×H)
Hydraulic connection
Refrigerant charge
Max. pool volume
NOTES:
The above maximum power or maximum current don't include the power or current of external
water pump.
The noise data is the average sound pressure value measured under high temperature and high
humidity heating conditions (Dry air 27℃-Relative humidity 80% - Water inlet temperature 26℃)
with a distance of 1m away from the unit.
This parametric is the maximum refrigerant charge amount of the unit.
The recommended maximum pool volume is based on the ideal heating condition that the pool
is well shaded; the filtration system runs for 15h per day, water temperature is maintained at
26℃,and ambient temperature ≥28℃.
Model
Heating capacity
Energy
efficiency
Heating capacity
Energy
efficiency
Cooling capacity
Energy
efficiency
Noise
Weight
Compressor
Fan motor
Refrigerant
Power supply
Protection
Mode
SWIMMING POOL HEAT PUMP (R32)
GRS-CP11Pd/NhA-K
GRS-CP11Pd/NhA-S
kW
2.2~11.8
13.0~5.8
kW
2.0~8.8
6.3~4.5
kW
4.3
3.2
kW
2.5
A
11
m
3
/h
3.8
kPa
5
dB(A)
52
mm
980×376×554
kg
43
mm
Hermetic Rotary DC Inverter Compressor
kg
0.52
m
3
75
Heating/Cooling/Automatic
8
GRS-CP18Pd/NhA-K
GRS-CP18Pd/NhA-S
5.5~18.8
11.0~5.2
3.0~15.1
6.0~4.0
7.8
4.0
4.0
17.5
6.5
12
55
1085×402×657
52.5
PVC 50/50
DC Fan Motor
R32
0.73
Single phase
220-240V ~ 50/60Hz
IPX4
95

Advertisement

Table of Contents
loading

Table of Contents