USING THE STATUS LED TO
TROUBLESHOOT SYSTEM PROBLEMS
Not all of the POWER WAVE® C300 errors will be displayed
on the user interface. There are three status lights that con-
tain error sequences that may not show up on the user inter-
face. If a problem occurs it is important to note the condition
of the status lights. Therefore, prior to cycling power to the
system, check the power source status light for error
sequences as noted below.
There are two externally mounted status lights located above
the wire drive in the wire feeder compartment. One of the sta-
tus lights is for the main control board ( labeled "status", and
one for the wire drive module. The third status light is internal
and is located on the input control board and can be seen by
looking through the left case side louvers.
Light
Condition
Steady Green
Blinking Green
Fast Blinking Green
Alternating Green and Red
Steady Red
Blinking Red
Status LED off
TROUBLESHOOTING AND REPAIR
TABLE F.1
Main control board status light and Wiredrive Status Light
System OK. Power source is operational, and is communicating normally with
all healthy peripheral equipment connected to its ArcLink network.
Occurs during power up or a system reset, and indicates the POWER
WAVE® C300 is mapping (identifying) each component in the system.
Normal for first 1-10 seconds after power is turned on, or if the system
configuration is changed during operation.
Indicates Auto-mapping has failed
Non-recoverable system fault. If the Status lights are flashing any
combination of red and green, errors are present. Read the error
code(s) before the machine is turned off.
Error Code interpretation through the Status light is detailed in the
Service Manual. Individual code digits are flashed in red with a long
pause between digits. If more than one code is present, the codes will
be separated by a green light. Only active error conditions will be
accessible through the Status Light.
Error codes can also be retrieved with the Diagnostics Utility (link
included on the Service Navigator DVD or available at www.power-
wavesoftware.com. This is the preferred method, since it can access
historical information contained in the error logs.
To clear the active error(s), turn power source off, and back on to
Not applicable.
Not applicable.
Not applicable.
POWER WAVE® C300
There is an audible beeper associated with this input control
board's status light. So the error codes on the input board
can be detected through either the status light or the status
beeper.
Included in this section is information about the Status Lights
and some basic troubleshooting charts for both machine and
weld performance.
The status lights on the main control board and the wire drive
module are dual-color LED's. Normal operation for each is
steady green. The status light on the input control board is
one color. Normal operation is for the status light to be off (
and the buzzer to be off).
Error conditions are indicated in the following Table F.1.
Meaning
reset.
F-11
Input control board
Not applicable.
Not applicable.
Not applicable.
Not applicable.
Not applicable.
Error
Code
interpretation
Individual code digits are flashed in
red with a long pause between dig-
its. These error codes are three
digit codes that all start with a
number three.
System OK