TROUBLESHOOTING AND REPAIR
F-31
F-31
SWITCH BOARD TEST PROCEDURE (continued)
TABLE F.6 – SWITCH BOARD RESISTANCE MEASUREMENTS (continued)
Full Bridge Low Sid e
B37( +) To
High Resistance
Machine "o ff" no
IGB Ts
B49( -)
Greate r than
input power applied.
Also
10,000 ohms
The Pla nar
B41( +) T o
Typical failure is a
Transformer
B49( -)
"short
electrically isolated
fro m the switch bo ard
at test points B37 and
B41