Enthermics ivNow-1 Owner's Manual

Fluid warmer
Hide thumbs Also See for ivNow-1:

Advertisement

Quick Links

ivNow-1 countertop module
ivNow-3 with 3-Liter Bag Tilt kit, countertop module
Printed in the U.S.A.
ivNow
Fluid Warmer
®
Owner's Manual
Specifications are subject to change without notice.
ivNow-6 with Vertical Wall
Mount Bracket Kit
W164 N9221 Water St | Menomonee Falls WI 53051
ivNow-1
ivNow-2
ivNow-3
ivNow-4
ivNow-5
ivNow-6
Enthermics Medical Systems
An ISO 13485:2003 certified company
Tel 262-251-8356 | 800-TO-B-WARM
generalinfo@enthermics.com
www.enthermics.com
Made in the U.S.A.
MN-28929 • Rev 6 • 01/17

Advertisement

Table of Contents
loading

Summary of Contents for Enthermics ivNow-1

  • Page 1 Fluid Warmer ® Owner’s Manual ivNow-1 ivNow-2 ivNow-3 ivNow-1 countertop module ivNow-4 ivNow-5 ivNow-6 ivNow-3 with 3-Liter Bag Tilt kit, countertop module ivNow-6 with Vertical Wall Mount Bracket Kit Enthermics Medical Systems An ISO 13485:2003 certified company W164 N9221 Water St | Menomonee Falls WI 53051 Tel 262-251-8356 | 800-TO-B-WARM generalinfo@enthermics.com...
  • Page 2: Table Of Contents

    Table of Contents Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . 3 Service Receipt of Appliance .
  • Page 3: Environmental Conditions

    . fi led and actively pursued . Enthermics cannot, however, 2 . Do not sign a delivery receipt or a freight bill until fi le any damage claims, assume the responsibility of any a proper count has been made and inspection of all claims, or accept deductions in payment for such claims .
  • Page 4: Unpacking

    . Store any accessories in a convenient place for future use . 4 . Slowly roll the appliance across high thresholds . Dimensions and Weights ivNow-1 ivNow-2 ivNow-3 ivNow-4 ivNow-5 ivNow-6 Height 8 .0"...
  • Page 5: Safety Procedures

    Safety Procedures • Fluid warmers are only intended for warming medical Knowledge of proper procedures is essential to the solutions for irrigation and injection prior to use . safe operation of electrically energized equipment . Refer to the labeling of the manufacturer of the The following signal words and symbols may be used products to be warmed regarding the recommended throughout this manual .
  • Page 6: Installation

    (Figure 2) . • All warmers can be wall-mounted using wall mount hardware (Figure 3) . • A single warmer (ivNow-1) can also be mounted on a mobile equipment pole . Figure 1 - 3-liter Bag Tilt Kit (countertop)
  • Page 7: Dimension Drawings

    . using mounting brackets* . ivNow-1 (one (1) bag capacity) can be placed directly on a ivNow-5 (fi ve (5) bag capacity) must be mounted on a wall countertop, mounted on a mobile equipment pole stand, using mounting brackets* .
  • Page 8: Electrical Information

    Verify the power requirements for the appliance . The power specifi cation is located on the Hazardous Voltage Present appliance identifi cation rating tag . This tag is permanently attached to the appliance . ivNow-1 Power Requirements ivNow-4 Power Requirements 120 V .A .C . — 60 Hz, 1 ph NEMA 5-15P 120 V .A .C .
  • Page 9 Hazardous Voltage Present appliance identifi cation rating tag . This tag is permanently attached to the appliance . ivNow-1 Power Requirements ivNow-4 Power Requirements 230 V .A .C . — 50/60 Hz, 1 ph 230 V .A .C . — 50/60 Hz, 1 ph...
  • Page 10: Preparation

    . Contact a local 0 .5-, 1-, 2- and 3-liter sizes cleaning supplier for product recommendations . • Three-liter bag capacity is available on ivNow-1, ivNow-2, and ivNow-3 with an additional adapter Preparation Before Operating the Warmer 1 . Remove and wash any detachable items such as the tilt • Multiple cavity warmers are available from the...
  • Page 11: Operating Instructions

    Operation Instructions Using the Fluid Controller Factory default temperature: • Injection (INJ) temperature: 40°C (104°F) How to Start the ivNow Fluid Warmer How to Display the Length of Time the Fluid has been at Set Temperature. 1 . Connect the fl uid warmer to an appropriate hospital grade receptacle —...
  • Page 12: Operating The Fluid Warmer

    Operation Instructions WARNING Operating the Fluid Controller To prevent an electrical shock hazard: Unplug the warmer if fluid spills inside the contoured warming module. Instructions: 1. Wipe the excess fluid from the module. How to Operate the ivNow Fluid Warmer 1 .
  • Page 13 Operation Instructions Bag of fluid does not rest on the sensor Warm-up Stabilization ivNow Temperature Profile (Set Point = 104°F) Bag of fluid is not ivNow-1 centered 1L Bag Fluid Temp Ambient Temp Time(min) MN-28929 • Rev 6 • 01/17 • ivNow® Fluid Warmer Owner’s Manual...
  • Page 14: Cleaning And Preventative Maintenance

    Cleaning and Preventative Maintenance CAUTION WARNING Fire hazard. To prevent serious personal injury, death, or property damage: Do not use flammable cleaning agents on Do not steam clean, hose down or flood the the appliance. interior or exterior with water or liquid solution of any kind.
  • Page 15: Preventative Maintenance Checklist

    Cleaning and Preventative Maintenance Preventative Maintenance Checklist Daily Checklist: ❏ Is the operation and care manual available? ❏ Has everyone been trained in the operation and safety instructions of this appliance? ❏ Do not exceed the capacity of the ivNow fl uid warmer . Weekly Checklist: ❏...
  • Page 16: Accessories Parts List

    3-Liter bag tilt kit for countertop models 3-Liter bag tilt kit for wall (5014128 shown) mounted models (5014131 shown) (ivNow-6 shown above) (ivNow-1 shown above) Bracket kit for seismic horizontal wall 3-Liter bag tilt kit for wall mount 5016602 (ivNow-3 to -6) mounted units (5017702 shown)
  • Page 17: How To Manually Reset The Warmer

    Troubleshooting Notice: Do not attempt to repair or service the warmer This section is provided for the assistance of beyond this point. Contact the manufacturer for the qualified and trained service technicians only nearest authorized service agent. Repairs made by and is not intended for use by untrained or any other service agent without prior authorization unauthorized service personnel.
  • Page 18 6 . Reposition the fl uid bag(s) to be slightly off centered and to the right inside the contoured warming module . 7 . If the error persists, a qualifi ed service technician should replace the sensor switch assembly . Contact service . Troubleshooting E-31 Product over temperature and...
  • Page 19: Parts Lists And Drawings

    Service Item Description Part Circuit board, LED, 120V BA-34834 Circuit board, LED, 230V BA-34833 Company label LA-28583 Cover, right end CV-28579 Screw, ka 40 x 12, philips flat head SC-28587 Washer, #8 ext lock WS-2333 Screw, M4 x 0 .70 x 10mm philips pan head SC-22273 5-15P hospital grade cord contact factory...
  • Page 20 Service Serial number is required for all inquiries. Part numbers and drawings are subject to change without notice. MN-28929 • Rev 6 • 01/17 • ivNow® Fluid Warmer Owner’s Manual...
  • Page 21 Service Serial number is required for all inquiries. Part numbers and drawings are subject to change without notice. MN-28929 • Rev 6 • 01/17 • ivNow® Fluid Warmer Owner’s Manual...
  • Page 22: Wire Diagram

    Wiring Diagrams ivNow-1 120V Wiring Diagram MN-28929 • Rev 6 • 01/17 • ivNow® Fluid Warmer Owner’s Manual...
  • Page 23 Wiring Diagrams ivNow-2 120V Wiring Diagram MN-28929 • Rev 6 • 01/17 • ivNow® Fluid Warmer Owner’s Manual...
  • Page 24 Wiring Diagrams ivNow-3 120V Wiring Diagram MN-28929 • Rev 6 • 01/17 • ivNow® Fluid Warmer Owner’s Manual...
  • Page 25 Wiring Diagrams ivNow-4 120V Wiring Diagram MN-28929 • Rev 6 • 01/17 • ivNow® Fluid Warmer Owner’s Manual...
  • Page 26 Wiring Diagrams ivNow-5 120V Wiring Diagram MN-28929 • Rev 6 • 01/17 • ivNow® Fluid Warmer Owner’s Manual...
  • Page 27 Wiring Diagrams ivNow-6 120V Wiring Diagram MN-28929 • Rev 6 • 01/17 • ivNow® Fluid Warmer Owner’s Manual...
  • Page 28 Wiring Diagrams ivNow-1 230V Wiring Diagram MN-28929 • Rev 6 • 01/17 • ivNow® Fluid Warmer Owner’s Manual...
  • Page 29 Wiring Diagrams ivNow-2 230V Wiring Diagram MN-28929 • Rev 6 • 01/17 • ivNow® Fluid Warmer Owner’s Manual...
  • Page 30 Wiring Diagrams ivNow-3 230V Wiring Diagram MN-28929 • Rev 6 • 01/17 • ivNow® Fluid Warmer Owner’s Manual...
  • Page 31 Wiring Diagrams ivNow-4 230V Wiring Diagram MN-28929 • Rev 6 • 01/17 • ivNow® Fluid Warmer Owner’s Manual...
  • Page 32 Wiring Diagrams ivNow-5 230V Wiring Diagram MN-28929 • Rev 6 • 01/17 • ivNow® Fluid Warmer Owner’s Manual...
  • Page 33 Wiring Diagrams ivNow-6 230V Wiring Diagram MN-28929 • Rev 6 • 01/17 • ivNow® Fluid Warmer Owner’s Manual...
  • Page 34 Enthermics Medical Systems An ISO 13485:2003 certified company W164 N9221 Water St | Menomonee Falls WI 53051 Tel 262-251-8356 | 800-TO-B-WARM generalinfo@enthermics.com www.enthermics.com Printed in the U.S.A. Specifications are subject to change without notice. Made in the U.S.A.