Enthermics EC Series Operation And Care Manual

Enthermics EC Series Operation And Care Manual

Blanket warmer
Hide thumbs Also See for EC Series:

Advertisement

Operation and Care Manual
EC Series Blanket Warmer
EC1540
EC2060
120v
EC1540 Shown with Optional
EC2060
Full-Perimeter Rubber Bumper
Enthermics Medical Systems
An ISO 13485:2003 certified company
PO Box 443, Menomonee Falls WI 53052-0443
W164 N9221 Water St, Menomonee Falls WI 53051
Tel 262-251-8356 | 800-TO-B-WARM
generalinfo@enthermics.com
www.enthermics.com
Printed in the U.S.A.
Specifications are Subject to Change Without Notice
Made in the U.S.A.
MN-28667 • Rev 4 • 12/16

Advertisement

Table of Contents
loading

Summary of Contents for Enthermics EC Series

  • Page 1 Operation and Care Manual EC Series Blanket Warmer EC1540 EC2060 120v EC1540 Shown with Optional EC2060 Full-Perimeter Rubber Bumper Enthermics Medical Systems An ISO 13485:2003 certified company PO Box 443, Menomonee Falls WI 53052-0443 W164 N9221 Water St, Menomonee Falls WI 53051 Tel 262-251-8356 | 800-TO-B-WARM generalinfo@enthermics.com...
  • Page 2: Table Of Contents

    Table of Contents Delivery Transportation Damage and Claims Unpacking Safety Procedures Installation Dimensions Electrical Information Operation Instructions Cleaning and Preventative Maintenance Troubleshooting Service Wiring Diagrams MN-28667 • • EC Series Blanket Warmer Rev 4 • 1 2 /1 6...
  • Page 3: Delivery

    3. Note all damage to packages directly on the carrier’s delivery receipt. MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 4: Unpacking

    Appliances on casters can move or roll on uneven floors. leveling appliance and handling accessories. MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 5: Safety Procedures

    NOTICE: For equipment delivered for use in any location regulated by the following directive: 2012/95/EC WEEE Do not dispose of electrical or electronic equipment with other municipal waste. MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 6: Installation

    The appliance is furnished with one (1) set of an additional safety feature. 5" (127mm) heavy-duty casters – two (2) rigid and two (2) The controller displays the temperature in whole degrees. swivel with locking brake. MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 7: Dimensions

    15.4 cubic feet (c. 44m 3 ) Right side 2" (51mm) Interior capacity (total) Rear 4" (102mm) Net weight 344 lb (156 kg) 4" (102mm) Ship weight 400 lb (181 kg) MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 8 20.6 cubic feet (c. 58m 3 ) Left and right side 2" (51mm) Interior capacity Rear 4" (102mm) Net weight 347 lb (157 kg) 4" (102mm) Ship weight 404 lb (183 kg) MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 9: Electrical Information

    Laboratories with Respect to Electrical Shock, UL File No. Fire and Mechanical Hazards only, in Accordance E201645 Protective Earth with UL 60601-1 and CAN/CSA C22.2 No. 601.1. Ground Symbol MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 10: Operation Instructions

    2. Make sure the product inside the appliance is at the Temperature correct operational temperature before using. 1. Press and hold the "TIMER" button and the up arrow button simultaneously. The temperature at the compartment sensor is displayed MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 11 The timer status indicator illuminates. How to Disable the Timer 1. Press and hold the "TIMER" button until the timer status indicator goes off. MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 12 NOTE: Failure to rotate the blankets can cause blankets to discolor a er an extended period of time. MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 13: Cleaning And Preventative Maintenance

    7. Clean the appliance glass with glass cleaner or minimum of once per day. Always wipe standing water as distilled vinegar. quickly as possible. 8. Replace the support assembly. MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 14 Do not allow the thermocouple to touch any surface. Monitor the temperature for one hour in an empty interior. NOTE: The blanket warmer temperature may fluctuate ±10° from the set point. *Contact service for immediate repair MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 15: Troubleshooting

    Part numbers and drawings are subject to change without notice. • Replace the defective relay. MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer • If the error continues, call service. E-50 Temperature...
  • Page 16 Part numbers and drawings are subject to change without notice. E-87 EEPROM Error • Ensure that all calibration offsets are properly set. MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer • If the error continues, call service for proper calibration instructions. E-90 A controller button...
  • Page 17: Service

    Service EC1540 Full Assembly and Interior Serial number is required for all inquiries. Part numbers and drawings are subject to change without notice. MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 18 Service EC2060 Full Assembly and Interior Blanket Insert Assembly Serial number is required for all inquiries. Part numbers and drawings are subject to change without notice. MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 19 GS-38504 * Not shown **Quantity varies † Quantity doubles for pass-through option Serial number is required for all inquiries. Part numbers and drawings are subject to change without notice. MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 20 Service EC1540 Electrical EC2060 Electrical Serial number is required for all inquiries. Part numbers and drawings are subject to change without notice. MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 21 24 Wire diagram* (located under top cover) 7756 77563 * Not shown † Optional Serial number is required for all inquiries. Part numbers and drawings are subject to change without notice. MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 22 SL-3063 Insulating sleeve CR-3226 Ring connector BU-3105 Shoulder bushing ST-2439 Stud, 10-32 Serial number is required for all inquiries. Part numbers and drawings are subject to change without notice. MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 23: Wiring Diagrams

    Wiring Diagram Serial number is required for all inquiries. Part numbers and drawings are subject to change without notice. MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 24 Wire Diagram Serial number is required for all inquiries. Part numbers and drawings are subject to change without notice. MN-28667 • Rev 4 • 12/16 • EC Series Blanket Warmer...
  • Page 25 Enthermics Medical Systems An ISO 13485:2003 certified company PO Box 443, Menomonee Falls WI 53052-0443 W164 N9221 Water St, Menomonee Falls WI 53051 Tel 262-251-8356 | 800-TO-B-WARM generalinfo@enthermics.com www.enthermics.com Printed in the U.S.A. Specifications are Subject to Change Without Notice...

This manual is also suitable for:

Ec1540Ec2060

Table of Contents