Advertisement

Operation and Care Manual
ivNow-1 countertop module
ivNow-3 with 3L Bag Tilt kit, countertop module
.
.
.
P R I N T E D I N U
S
A
.
.
.
p r i n t e d i n u
s
a
ivNow-6 with Vertical Wall
Mount Bracket Kit
S P E C I F I C A T I O N S A R E S U B J E C T T O C H A N G E W I T H O U T N O T I C E
ivNow-1
ivNow-2
ivNow-3
ivNow-4
ivNow-5
ivNow-6
ivNow
120V & 230V
ENTHERMICS MEDICAL SYSTEMS
An ISO 13485:2003 certified company
PO Box 443, Menomonee Falls WI 53052-0443
W164 N9221 Water St, Menomonee Falls WI 53051
Tel 262-251-8356 | 800-TO-B-WARM
generalinfo@enthermics.com
M N - 2 8 9 2 9 ( R e v 4 ) • 0 6 / 1 5
®
www.enthermics.com
.
.
.
M A D E I N T H E U
S
A

Advertisement

Table of Contents
loading

Summary of Contents for Enthermics ivNow Series

  • Page 1 ® 120V & 230V ivNow-6 with Vertical Wall Mount Bracket Kit ENTHERMICS MEDICAL SYSTEMS An ISO 13485:2003 certified company ivNow-3 with 3L Bag Tilt kit, countertop module PO Box 443, Menomonee Falls WI 53052-0443 W164 N9221 Water St, Menomonee Falls WI 53051 Tel 262-251-8356 | 800-TO-B-WARM generalinfo@enthermics.com...
  • Page 2: Table Of Contents

    T A B L E O F C O N T E N T S Environmental Conditions ......1 Operating Instructions Delivery.
  • Page 3: Environmental Conditions

    D A M A G E & C L A I M S All Enthermics Medical Systems 4. Make certain the driver signs this receipt. If he refuses equipment is sold F.O.B. shipping point, to sign, make a notation of this refusal on the receipt.
  • Page 4: Unpacking

    U N P A C K I N G A N D S E T - U P 1. Carefully remove the appliance from the carton. NOTE: Do not discard the carton and other packaging material until you have inspected the unit for hidden damage and tested it for proper operation. 2.
  • Page 5: Safety Procedures And Precautions

    S A F E T Y P R O C E D U R E S A N D P R E C A U T I O N S Knowledge of proper procedures is essential to the 1. Fluid warmers are ONLY intended for warming medical safe operation of electrically energized equipment.
  • Page 6: Preparation

    P R E P A R A T I O N Before operating the module(s), clean the exterior of the unit with a damp cloth and general hospital cleaner (isopropyl alcohol) E L E C T R I C A L I N F O R M A T I O N The power specifications are located on the unit identification nameplate.
  • Page 7: 230V Electrical Information

    Before operating the module(s), clean the exterior of the unit with a damp cloth and general hospital cleaner (isopropyl alcohol) E L E C T R I C A L I N F O R M A T I O N The power specifications are located on the unit identification nameplate.
  • Page 8: General Information

    GE NE RA L I N F O R MA TI O N D A N G E R The ivNow fluid warmer quickly warms and maintains the temperature of injection/intravenous and irrigation solutions prior to their use. The specially contoured warming module At no time should the interior or cradles solution bags in 0.5-, 1-, 2- &...
  • Page 9: Dimension Drawings & Configurations

    i v Now DI MEN SI ON S Note: ** maintain a minimum of 4" (102mm) † • Countertop unit (1 or 2 cavity), power cord exits back of unit. clearance for bending of cord. • Wall mounted units (up to 6 cavities), power cord exits bottom †...
  • Page 10: Options & Accessories

    i v No w O P TI ON S A ND A C C ES SO RI ES ivNow-1 ivNow-2 ivNow-3 ivNow-4, -5, -6 ACCESSORIES (cord exits back of unit) (cord exits back of unit) (cord exits back of unit) —...
  • Page 11: Control Features

    C O N TR OL F EA TU R ES NOTE: Placing a warmed fluid bag with a temperature CONTROL AND DISPLAY higher than the set-point in the module will cause status key status indicator light display the display to flash the actual temperature. The display will continue flashing until the temperature falls below the set point.
  • Page 12: Installation

    I NST A L LA TI O N INSTALLATION/MOUNTING OF UNIT ivNow modular units can be installed in a variety of ways. • A single or double unit (ivNow-1 or ivNow-2) can be used on a countertop without any special mounting hardware.
  • Page 13: Operation Procedures

    OP ERA TI ON PR O C ED U R ES ivNOW CAPACITY INFORMATION Figure 1 - Load bag The ivNow warming module accommodates fluids packaged in bags. Each warming module cradles solution bags in 0.5-, 1-, 2- & 3-liter sizes. OPERATION OF UNIT 1.
  • Page 14: Care And Cleaning

    C A R E A N D C L E A N I N G The cleanliness and appearance of this equipment will contribute considerably to its operating efficiency. Make certain the module is kept free of any debris that may accumulate. Good equipment that is kept clean works better and lasts longer.
  • Page 15: Troubleshooting Guide

    If your unit is not operating properly, check the following before calling your authorized service agent. Check the power applied to the unit. Is the plug in outlet? Check to make sure the power switch, located on the side of the unit, is in the ON (I) position.
  • Page 16: Service Parts Lists And Drawings

    S E R V I C E ITEM DESCRIPTION PART NUM CIRCUIT BOARD, LED, 120V BA-34834 CIRCUIT BOARD, LED, 230V BA-34833 COMPANY LABEL LA-28583 COVER, RT END CV-28579 SCREW, KA 40 x 12, PHIL, FLAT HEAD SC-28587 WASHER, #8 EXT LOCK WS-2333 M4 x 6mm PH PAN HD M/S 18-8 SC-22273...
  • Page 17 S E R V I C E i v N o w F L U I D W A R M I N G M O D U L E SERIAL NUMBER IS REQUIRED FOR ALL INQUIRIES PART NUMBERS AND DRAWINGS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Always include both model and serial numbers in your correspondence regarding the unit.
  • Page 18 S E R V I C E i v N o w F L U I D W A R M I N G M O D U L E c o n t i n u e d SERIAL NUMBER IS REQUIRED FOR ALL INQUIRIES PART NUMBERS AND DRAWINGS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
  • Page 19 ivNow-1 120V Wiring Diagram M N-28929 (R E V . 4 ) 0 6/1 5 • IV NOW M ANUA L • 17...
  • Page 20 ivNow-2 120V Wiring Diagram M N-28929 (R E V . 4 ) 0 6/1 5 • IV NOW M ANUA L • 18...
  • Page 21 ivNow-3 120V Wiring Diagram M N-28929 (R E V . 4 ) 0 6/1 5 • IV NOW M ANUA L • 19...
  • Page 22 ivNow-4 120V Wiring Diagram M N-28929 (R E V . 4 ) 0 6/1 5 • IV NOW M ANUA L • 20...
  • Page 23 ivNow-5 120V Wiring Diagram M N-28929 (R E V . 4 ) 0 6/1 5 • IV NOW M ANUA L • 21...
  • Page 24 ivNow-6 120V Wiring Diagram M N-28929 (R E V . 4 ) 0 6/1 5 • IV NOW M ANUA L • 22...
  • Page 25 ivNow-1 230V Wiring Diagram M N-28929 (R E V . 4 ) 0 6/1 5 • IV NOW M ANUA L • 23...
  • Page 26 ivNow-2 230V Wiring Diagram M N-28929 (R E V . 4 ) 0 6/1 5 • IV NOW M ANUA L • 24...
  • Page 27 ivNow-3 230V Wiring Diagram M N-28929 (R E V . 4 ) 0 6/1 5 • IV NOW M ANUA L • 25...
  • Page 28 ivNow-4 230V Wiring Diagram M N-28929 (R E V . 4 ) 0 6/1 5 • IV NOW M ANUA L • 26...
  • Page 29 ivNow-5 230V Wiring Diagram M N-28929 (R E V . 4 ) 0 6/1 5 • IV NOW M ANUA L • 27...
  • Page 30 ivNow-6 230V Wiring Diagram M N-28929 (R E V . 4 ) 0 6/1 5 • IV NOW M ANUA L • 28...
  • Page 31 ENTHERMICS MEDICAL SYSTEMS An ISO 13485:2003 certified company PO Box 443, Menomonee Falls WI 53052-0443 W164 N9221 Water St, Menomonee Falls WI 53051 Tel 262-251-8356 | 800-TO-B-WARM generalinfo@enthermics.com www.enthermics.com P R I N T E D I N U S P E C I F I C A T I O N S A R E S U B J E C T T O C H A N G E W I T H O U T N O T I C E...

This manual is also suitable for:

Ivnow-1Ivnow-2Ivnow-6Ivnow-5Ivnow-4Ivnow-3

Table of Contents