Enthermics DC250 Owner's Manual

Enthermics DC250 Owner's Manual

Designer series blanket warmer
Hide thumbs Also See for DC250:

Advertisement

Owner's Manual
Designer Series Blanket Warmer
DC150
DC250
DC350
DC350
DC250
DC400
DC150
(shown with optional timer)
DC750
DC750
(shown with optional timer)
DC400
(shown with optional timer)
Enthermics Medical Systems
An ISO 13485:2016 certified company
W164 N9221 Water St | Menomonee Falls WI 53051
Tel 262-251-8356 | 800-TO-B-WARM
generalinfo@enthermics.com
www.enthermics.com
Printed in the U.S.A.
Specifications are subject to change without notice.
Made in the U.S.A.
MN-37072 • Rev 5 • 12/18

Advertisement

Table of Contents
loading

Summary of Contents for Enthermics DC250

  • Page 1 (shown with optional timer) DC750 DC750 (shown with optional timer) DC400 (shown with optional timer) Enthermics Medical Systems An ISO 13485:2016 certified company W164 N9221 Water St | Menomonee Falls WI 53051 Tel 262-251-8356 | 800-TO-B-WARM generalinfo@enthermics.com www.enthermics.com Printed in the U.S.A.
  • Page 2: Table Of Contents

    Table of Contents Delivery Transportation Damage and Claims Unpacking Safety Procedures Installation Dimensions Electrical Information Operation Instructions Cleaning and Preventative Maintenance Dimension Drawings Troubleshooting Service Wiring Diagrams Refer to the wire diagram located under the lid of the appliance Authorized Representative: MDSS GmbH Schi graben 41 30175 Hannover...
  • Page 3: Delivery

    Enthermics will continue our policy of assisting our the receiving area. Do not wait until aft er the warmer customers in collecting claims which have been properly is moved to a storage area.
  • Page 4: Unpacking

    Unpacking 1. Carefully remove the appliance from the carton or crate. NOTE: Do not discard the carton and other packaging material until the appliance has been inspected for hidden damage and tested for proper operation. 2. Read all instructions in this manual carefully before initiating the installation of this appliance, using the appliance or performing routine maintenance.
  • Page 5: Safety Procedures

    • The blanket chamber is intended for warming dry, cotton blankets or towels only. The blanket chamber is designed to elevate blanket temperatures to a level which will increase patient comfort. Safety Procedures • The fl uid chamber is only intended for warming medical solutions for irrigation and injection prior to •...
  • Page 6: Installation

    Installation WARNING DANGER To prevent serious personal injury, death, or To prevent serious personal injury, death, property damage: or property damage: Do not steam clean, hose down or flood the Do not use this warmer in the presence of interior or exterior with water or liquid solution flammable anesthetic mixtures (with air of any kind.
  • Page 7: Dimensions

    (est.) Electrical 120 V.A.C. — 60 Hz, 1 ph NEMA 5-15P 15A - 125V Plug 0.6 kW, 5.0 Amps DC250 Hospital Grade Safety Class I Equipment IPX-0 Dimensions (H x W x D) No Applied Parts Mode of Operation: Continuous With feet 22"...
  • Page 8: Electrical Information

    2.5 ft IPX-0 Weight** Net: 134 lbs (61 kg) Ship: 196 lbs (89 kg) eight** DC250 DC750 Net: 67 lbs (30 kg) Ship: 118 lbs (54 kg) (est.) (est.) *Other international plugs are available, contact the manufacturer for more information.
  • Page 9 Electrical Information Guidance and Manufacturer’s Declaration The warmer requires special precautions may result if the power cord attached is altered or a regarding EMC (Electromagnetic manufacturer supplied power cable is not used. Compatibility) and needs to be installed The warmer should not be used adjacent to or stacked with and put into service according to the other equipment.
  • Page 10 Electrical Information Electromagnetic Emissions The warmer is intended for use in the electromagnetic environment specifi ed below. The customer or the end user of this warmer should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment - guidance Portable and mobile RF communications equipment should be used no closer to any part of the warmer, including...
  • Page 11: Operation Instructions

    Operation Instructions Blanket Electronic Control Features The following refers to features that are available when the electronic control is powered on. Electronic Control and LED Display Up Arrow On/Off LED Digital Temperature Button Button Display Recall Button Temperature Range: 32°C-71°C (90°F-160°F) Button Lockout Error Down Arrow...
  • Page 12 Operation Instructions Blanket Electronic Control Features (continued) Electronic Control and LED Display Up Arrow On/Off Temperature Button Button Recall Button Temperature Range: 32°C-71°C (90°F-160°F) Button Lockout Error Down Arrow Interior Indicator Light Indicator Light Button Light Button Temperature Format Selection While the electronic control is in off...
  • Page 13 Operation Instructions Optional Timer Control Feature Optional Timer Control Electronic Control and LED Display Timer On/Off Set or View Up Arrow On/Off Temperature Start Time Button Button Button Button Recall Button On/Off Indicator Light Time Button Set or View Stop Time Button Button Lockout Error Down Arrow...
  • Page 14 Operation Instructions Optional Timer Control Feature (continued) Optional Timer Control Electronic Control and LED Display Set or View Timer On/Off Up Arrow On/Off Temperature Button Start Time Button Button Button Recall Button On/Off Indicator Light Time Button Set or View Stop Time Button Button Lockout Error...
  • Page 15 Section Title WARNING Electronic Control and LED Display On/Off Temperature Button Button Recall Button To prevent personal injury or property damage: Blanket support assembly and shelf must be in place to prevent the blankets from being scorched or discolored. NOTICE: The blanket support assembly and shelf must be installed to prevent blankets from scorching or discoloring.
  • Page 16: Cleaning And Preventative Maintenance

    Cleaning and Preventative Maintenance WARNING WARNING To prevent serious personal injury, death, or Electric shock hazard. property damage: Perform lockout/tagout procedures before Do not steam clean, hose down or flood the cleaning or servicing this appliance. interior or exterior with water or liquid solution of any kind.
  • Page 17 Cleaning and Preventative Maintenance Preventative Maintenance Checklist Daily Checklist: Is the operation and care manual available? Has everyone been properly trained in the operation and safety instructions of this appliance? Is the appliance properly loaded? Blankets must not exceed the height of the support assembly.
  • Page 18: Dimension Drawings

    Dimension Drawings Clearance requirements: DC150 with standard feet 3" (76mm) from rear Dimensions (H x W x D) 1" (25mm) from top and sides With feet 17.0" x 18.5" x 20" (432mm x 470mm x 508mm) (standard) 3/4" (19mm) from bottom Capacity 1.5 ft Weight**...
  • Page 19 Dimension Drawings Clearance requirements: DC250 with standard feet 3" (76mm) from rear Dimensions (H x W x D) 1" (25mm) from top and sides With feet 22" x 18.5" x 23" (559mm x 470mm x 584mm) (standard) 3/4" (19mm) from bottom With plate and 26.25"...
  • Page 20 Dimension Drawings Clearance requirements: DC250 with optional plate and casters 3" (76mm) from rear #5017542 (white epoxy coated) – 3" (76mm) casters (2 rigid, 2 swivel with brake) #5017544 (stainless steel) – 3" (76mm) casters (2 rigid, 2 swivel with brake) 1"...
  • Page 21 Dimension Drawings Clearance requirements: DC250 with optional bumpers and casters 3" (76mm) from rear #5017546 (white epoxy coated) – 3" (76mm) casters (2 rigid, 2 swivel with brake) #5017548 (stainless steel) – 3" (76mm) casters (2 rigid, 2 swivel with brake) 1"...
  • Page 22 Dimension Drawings Clearance requirements: DC350 with standard feet 3" (76mm) from rear Dimensions (H x W x D) 1" (25mm) from top and sides With feet 28" x 18.5" x 23" (711mm x 470mm x 584mm) (standard) 3/4" (19mm) from bottom With plate and 32.25"...
  • Page 23 Dimension Drawings Clearance requirements: DC350 with optional plate and casters 3" (76mm) from rear #5017542 (white epoxy coated) – 3" (76mm) casters (2 rigid, 2 swivel with brake) #5017544 (stainless steel) – 3" (76mm) casters (2 rigid, 2 swivel with brake) 1"...
  • Page 24 Dimension Drawings Clearance requirements: DC350 with optional bumpers and casters 3" (76mm) from rear #5017546 (white epoxy coated) – 3" (76mm) casters (2 rigid, 2 swivel with brake) #5017548 (stainless steel) – 3" (76mm) casters (2 rigid, 2 swivel with brake) 1"...
  • Page 25 Dimension Drawings Clearance requirements: DC400 with standard feet 3" (76mm) from rear Dimensions (H x W x D) 1" (25mm) from top and sides With feet 22" x 24.0" x 25.0" (559mm x 610mm x 635mm) (standard) 3/4" (19mm) from bottom With plate and 26.25"...
  • Page 26 Dimension Drawings Clearance requirements: DC400 with optional plate and casters 3" (76mm) from rear #5017543 (white epoxy coated) – 3" (76mm) casters (2 rigid, 2 swivel with brake) #5017545 (stainless steel) – 3" (76mm) casters (2 rigid, 2 swivel with brake) 1"...
  • Page 27 Dimension Drawings Clearance requirements: DC400 with optional bumpers and casters 3" (76mm) from rear #5017547 (white epoxy coated) – 3" (76mm) casters (2 rigid, 2 swivel with brake) #5017549 (stainless steel) – 3" (76mm) casters (2 rigid, 2 swivel with brake) 1"...
  • Page 28 Dimension Drawings Clearance requirements: DC750 with standard feet 3" (76mm) from rear Dimensions (H x W x D) 1" (25mm) from top and sides With feet 35.5" x 24.0" x 25.25" (902mm x 610mm x 641mm) (standard) 3/4" (19mm) from bottom With bumper and 39.25”...
  • Page 29 Dimension Drawings Clearance requirements: DC750 with optional bumpers and casters 3" (76mm) from rear #5017547 (white epoxy coated) – 3" (76mm) casters (2 rigid, 2 swivel with brake) #5017549 (stainless steel) – 3" (76mm) casters (2 rigid, 2 swivel with brake) 1"...
  • Page 30 Dimension Drawings Clearance requirements: DC750 with optional casters 3" (76mm) from rear #5018646 – 3" (76mm) casters (2 swivel, 2 swivel with brake) 1" (25mm) from top and sides 3/4" (19mm) from bottom 13.4" (340mm) IEC Cord Inlet Cord length: 6 ft (1.83m) (est.) 48.3"...
  • Page 31: Troubleshooting

    Troubleshooting NOTE: The Blanket warmer temperature may fluctuate ±10° This section is provided for the assistance from the set point. of qualified and trained service technicians only and is not intended All non-critical codes can be cleared using the ON/OFF for use by untrained or unauthorized button.
  • Page 32 P331 Pad sensor 3 • Acknowledge error by pressing the ON/OFF button. P431 Pad sensor 4 • Allow the warmer to cool. P531 Pad sensor 5 • Call service if the error persists. P631 Pad sensor 6 Troubleshooting P731 Pad sensor 7 *E-33 Cavity sensor •...
  • Page 33: Service

    Service Part numbers and drawings are subject to change without notice. Fuse Replacement WARNING For protection against fire and electrical shock use only UL listed 10A, 250V fast acting fuses, 5mm x 20mm (F1, F2). Access should be made FU-34955 by qualified service technicians only.
  • Page 34 5018259 Seismic Mounting Brackets Note: special installation requirements apply 1014403 1014403 1014403 1014403 1017494 Stacking Hardware - DC250 or DC350 double stacked White Epoxy Coated — 5013021 5013021 — — Stacking Hardware - DC400 or DC750 double stacked White Epoxy Coated —...
  • Page 35 Service Part numbers and drawings are subject to change without notice. Full Assembly A Item Description Part Item Description Part Side cover, 1.5 1011024 Rear cover, stainless steel, 1.5 1014262 Side cover, stainless steel, 1.5 1014261 Rear cover, 2.5 3 5013521 Side cover, 2.5 1011269...
  • Page 36 Service Part numbers and drawings are subject to change without notice. Full Assembly B Item Description Part Blanket support bottom, 1.5 1011045 Blanket support bottom, 2.5 1011265 Blanket support bottom, 3.5 1011265 Blanket support bottom, 4.0 1011471 Blanket support bottom, 7.5 1011471 Blanket support side, 1.5 1012865...
  • Page 37 Service Part numbers and drawings are subject to change without notice. Full Assembly C 16 16 16 14 16 13 Item Description Part Item Description Part Chassis, 3-zone, 120V, 1.5 /2.5 5017792 Spring, door, 1.5 SD-29340 Chassis, 3-zone, 230V, 1.5 /2.5 5017795 Spring, door, 2.5...
  • Page 38 Service Part numbers and drawings are subject to change without notice. Electrical Chassis Item Description Part Power supply, 20W, 5 volt DC BA-34965 Relay board, 3-zone, 120V, 1.5 /2.5 BA-39301 Relay board, 4-zone, 120V, 3.5 /4.0 /7.5 BA-39302 Relay board, 3-zone, 230V, 1.5 /2.5 BA-39303 Relay board, 4-zone, 230V, 3.5...
  • Page 39 Service Part numbers and drawings are subject to change without notice. Door Latch & Sensor Item Description Part Plate, latch pull, 1.5 1011197 Plate, latch pull, 2.5 /4.0 1011263 Plate, latch pull, 3.5 1011295 Plate, latch pull, 7.5 1011850 Guide, low profile rail, 1.5 GI-29204 Guide, low profile rail, 2.5 /3.5...
  • Page 40 Service Part numbers and drawings are subject to change without notice. Control Interface Item Description Part Panel, interface mount, 18.5", 1.5 /2.5 /3.5 1011336 Panel, interface mount, 24", 4.0 /7.5 1011482 Panel, front top trim, painted, 18.5", 1.5 /2.5 /3.5 1011032 Panel, front top trim, painted, 24", 4.0 /7.5...
  • Page 41 Service Part numbers and drawings are subject to change without notice. Shelf (DC350/DC750 only) Item Description Part Panel, heat shelf, top, 3.5 1023672 Panel, heated shelf, top, 7.5 1014609 Shelf insulation, 3.5 1025092 Shelf insulation, 7.5 1017637 Heater pad, 3.5 EL-39472 Heater pad, 7.5 EL-36692...
  • Page 42: Wiring Diagrams

    Wiring Diagram Refer to wire diagram included with the unit MN-37072 • Rev 5 • 12/18 • Designer Series Blanket Warmer...
  • Page 43 Enthermics Medical Systems An ISO 13485:2016 certified company W164 N9221 Water St | Menomonee Falls WI 53051 Tel 262-251-8356 | 800-TO-B-WARM generalinfo@enthermics.com www.enthermics.com Printed in the U.S.A. Specifications are subject to change without notice. Made in the U.S.A.

This manual is also suitable for:

Dc150Dc350Dc400Dc750