Table of Contents
loading

Summary of Contents for Enthermics DC250

  • Page 1 (shown with optional timer) DC750 DC750 (shown with optional timer) DC400 (shown with optional timer) Enthermics Medical Systems An ISO 13485:2003 certified company PO Box 443, Menomonee Falls WI 53052-0443 W164 N9221 Water St, Menomonee Falls WI 53051 Tel 262-251-8356 | 800-TO-B-WARM generalinfo@enthermics.com www.enthermics.com...
  • Page 2: Table Of Contents

    Table of Contents Delivery Transportation Damage and Claims Unpacking Safety Procedures Installation Dimensions Electrical Information Operation Instructions Cleaning and Preventative Maintenance Dimension Drawings Troubleshooting Service Wiring Diagrams Refer to the wire diagram located under the lid of the appliance Authorized Representative: MDSS GmbH Schi graben 41 30175 Hannover...
  • Page 3: Delivery

    This manual must be read and understood by all people using or installing the appliance. Contact the Purchased From: ______________________________________________ Enthermics service department if there are any questions Date Installed: ____________________ Voltage: _____________ concerning installation, operation, or maintenance. Transportation Damage and Claims All Enthermics Medical Systems appliances 4.
  • Page 4: Unpacking

    Unpacking 1. Carefully remove the appliance from the carton or crate. NOTE: Do not discard the carton and other packaging material until the appliance has been inspected for hidden damage and tested for proper operation. 2. Read all instructions in this manual carefully before initiating the installation of this appliance, using the appliance or performing routine maintenance.
  • Page 5: Safety Procedures

    Safety Procedures • This blanket warmer is intended for warming dry, Knowledge of proper procedures is essential to the cotton blankets only. No other use for this appliance is safe operation of electrically energized appliances. The authorized or recommended. following hazard signal words and symbols may be used throughout this manual.
  • Page 6: Installation

    Installation DANGER DANGER To prevent serious personal injury, death, or To prevent serious injury, death, or property damage: property damage: Do not steam clean, hose down or flood the Do not use this warming appliance in interior or exterior with water or liquid solution the presence of flammable anesthetic of any kind.
  • Page 7: Dimensions

    Ship: 98 lbs (44 kg) (est.) Electrical 120 V.A.C. — 60 Hz, 1 ph NEMA 5-15P 15A - 125V Plug 0.6 kW, 5.0 Amps DC250 Hospital Grade Safety Class I Equipment E471516 IPX-0 No Applied Parts Dimensions (H x W x D)
  • Page 8: Electrical Information

    IPX-0 pacity IPX-0 Weight** Net: 134 lbs (61 kg) Ship: 196 lbs (89 kg) eight** DC250 DC750 Net: 67 lbs (30 kg) Ship: 118 lbs (54 kg) (est.) (est.) *Other international plugs are available, contact factory for more information. Other international plugs are available, contact factory for more information.
  • Page 9 Electrical Information Guidance and Manufacturer’s Declaration The appliance requires special precautions may result if the power cord attached is altered or a regarding EMC (Electromagnetic manufacturer supplied power cable is not used. Compatibility) and needs to be installed The appliance should not be used adjacent to or stacked and put into service according to the with other equipment.
  • Page 10 Electrical Information Electromagnetic Emissions The appliance is intended for use in the electromagnetic environment speci ed below. The customer or the end user of this appliance should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment - guidance Portable and mobile RF communications equipment should be used no closer to any part of the appliance, including...
  • Page 11: Operation Instructions

    Operation Instructions Blanket Electronic Control Features The following refers to features that are available when the electronic control is powered on. Electronic Control and LED Display Up Arrow On/Off LED Digital Temperature Button Button Display Recall Button Temperature Range: 32°C-71°C (90°F-160°F) Button Lockout Error Down Arrow...
  • Page 12 Operation Instructions Blanket Electronic Control Features (continued) Electronic Control and LED Display Up Arrow On/Off Temperature Button Button Recall Button Temperature Range: 32°C-71°C (90°F-160°F) Button Lockout Error Down Arrow Interior Indicator Light Indicator Light Button Light Button Temperature Format Selection While the electronic control is in off state, press and hold the Temperature Recall button for four (4) seconds to...
  • Page 13 Operation Instructions Optional Timer Control Feature Optional Timer Control Electronic Control and LED Display Set or View Timer On/Off Up Arrow On/Off Temperature Start Time Button Button Button Button Recall Button On/Off Indicator Light Time Button Set or View Stop Time Button Button Lockout Error Down Arrow...
  • Page 14 Operation Instructions Optional Timer Control Feature (continued) Optional Timer Control Electronic Control and LED Display Set or View Timer On/Off Up Arrow On/Off Temperature Start Time Button Button Button Button Recall Button On/Off Indicator Light Time Button Set or View Stop Time Button Error Button Lockout...
  • Page 15 Operation Instructions WARNING To prevent personal injury or property damage: Blanket support assembly and shelf Electronic Control and LED Display must be in place to prevent the blankets from On/Off Temperature being scorched or discolored. Button Button Recall Button NOTICE: Do not use flammable appliance cleaning agents or blanket cleaning agents that cause fabric to become brittle over time.
  • Page 16: Cleaning And Preventative Maintenance

    Cleaning and Preventative Maintenance DANGER Cleaning Agents Use non-abrasive cleaning products designed for use on stainless steel surfaces. Cleaning agents must To prevent serious personal injury, death, or be chloride-free compounds and must not contain property damage: quaternary salts. Never use hydrochloric acid (muriatic Do not steam clean, hose down or flood the acid) on stainless steel surfaces.
  • Page 17 Cleaning and Preventative Maintenance Preventative Maintenance Checklist Daily Checklist: ❏ Is the operation and care manual available? ❏ Has everyone been properly trained in the operation and safety instructions of this appliance? ❏ Do not overload the appliance. Blankets must not exceed the height of the support assembly.
  • Page 18: Dimension Drawings

    Dimension Drawings Clearance requirements: DC150 with standard feet 3" (76mm) from rear Dimensions (H x W x D) 1" (25mm) from top and sides With feet 17.0" x 18.5" x 22.7" (431mm x 470mm x 577mm) (standard) 3/4" (19mm) from bottom With casters 20.5"...
  • Page 19 Dimension Drawings Clearance requirements: DC150 with optional casters 3" (76mm) from rear #5012693 – 3" (76mm) casters (2 swivel, 2 swivel with brake) 1" (25mm) from top and sides 3/4" (19mm) from bottom 9.2 " (235mm) IEC Cord Inlet Cord length: 6 ft (1.83m) (est.) 36.0"...
  • Page 20 Dimension Drawings DC250 with standard feet Clearance requirements: 3" (76mm) from rear Dimensions (H x W x D) 1" (25mm) from top and sides With feet 21.9" x 18.5" x 25.7" (557mm x 470mm x 653mm) (standard) 3/4" (19mm) from bottom With plate and 26.3"...
  • Page 21 Dimension Drawings Clearance requirements: DC250 with optional plate and casters 3" (76mm) from rear #5017542 (white epoxy coated) – 3" (76mm) casters (2 rigid, 2 swivel with brake) #5017544 (stainless steel) – 3" (76mm) casters (2 rigid, 2 swivel with brake) 1"...
  • Page 22 Dimension Drawings Clearance requirements: DC250 with optional bumpers and casters 3" (76mm) from rear #5017546 (white epoxy coated) – 3" (76mm) casters (2 rigid, 2 swivel with brake) #5017548 (stainless steel) – 3" (76mm) casters (2 rigid, 2 swivel with brake) 1"...
  • Page 23 Dimension Drawings Clearance requirements: DC350 with standard feet 3" (76mm) from rear Dimensions (H x W x D) 1" (25mm) from top and sides With feet 27.9" x 18.5" x 25.7" (709mm x 470mm x 653mm) (standard) 3/4" (19mm) from bottom With plate and 32.2"...
  • Page 24 Dimension Drawings Clearance requirements: DC350 with optional plate and casters 3" (76mm) from rear #5017542 (white epoxy coated) – 3" (76mm) casters (2 rigid, 2 swivel with brake) #5017544 (stainless steel) – 3" (76mm) casters (2 rigid, 2 swivel with brake) 1"...
  • Page 25 Dimension Drawings Clearance requirements: DC350 with optional bumpers and casters 3" (76mm) from rear #5017546 (white epoxy coated) – 3" (76mm) casters (2 rigid, 2 swivel with brake) #5017548 (stainless steel) – 3" (76mm) casters (2 rigid, 2 swivel with brake) 1"...
  • Page 26 Dimension Drawings Clearance requirements: DC400 with standard feet 3" (76mm) from rear Dimensions (H x W x D) 1" (25mm) from top and sides With feet 21.9" x 24.0" x 28.0" (557mm x 610mm x 712mm) (standard) 3/4" (19mm) from bottom With plate and 26.1"...
  • Page 27 Dimension Drawings Clearance requirements: DC400 with optional plate and casters 3" (76mm) from rear #5017543 (white epoxy coated) – 3" (76mm) casters (2 rigid, 2 swivel with brake) #5017545 (stainless steel) – 3" (76mm) casters (2 rigid, 2 swivel with brake) 1"...
  • Page 28 Section Title Clearance requirements: DC400 with optional bumpers and casters 3" (76mm) from rear #5017547 (white epoxy coated) – 3" (76mm) casters (2 rigid, 2 swivel with brake) #5017549 (stainless steel) – 3" (76mm) casters (2 rigid, 2 swivel with brake) 1"...
  • Page 29 Dimension Drawings Clearance requirements: DC750 with standard feet 3" (76mm) from rear Dimensions (H x W x D) 1" (25mm) from top and sides With feet 35.4" x 24.0" x 28.0" (900mm x 610mm x 712mm) (standard) 3/4" (19mm) from bottom With bumper and 39.3"...
  • Page 30 Dimension Drawings Clearance requirements: DC750 with optional bumpers and casters 3" (76mm) from rear #5017547 (white epoxy coated) – 3" (76mm) casters (2 rigid, 2 swivel with brake) #5017549 (stainless steel) – 3" (76mm) casters (2 rigid, 2 swivel with brake) 1"...
  • Page 31 Dimension Drawings Clearance requirements: DC750 with optional casters 3" (76mm) from rear #5018646 – 3" (76mm) casters (2 swivel, 2 swivel with brake) 1" (25mm) from top and sides 3/4" (19mm) from bottom 12.0 " (305mm) IEC Cord Inlet Cord length: 6 ft (1.83m) (est.) 47.0"...
  • Page 32: Troubleshooting

    Troubleshooting NOTE: All non-critical codes can be cleared using the on/off This section is provided for the assistance button. Critical errors (marked with a *) can only be of qualified and trained service cleared by turning the power switch at the rear of the technicians only and is not intended appliance off...
  • Page 33 • Call service. P131 Pad sensor 1 Heater pad over-temp error P231 Pad sensor 2 • Soft ware disengages heating pads. P331 Pad sensor 3 • Acknowledge error by pressing on/off button. Troubleshooting P431 Pad sensor 4 • Allow appliance to cool. P531 Pad sensor 5 Troubleshooting Guide...
  • Page 34: Service

    Service Part numbers and drawings are subject to change without notice. Fuse Replacement WARNING For protection against fire and electrical shock use only UL listed 10A, 250V fast acting fuses, 5mm x 20mm (F1, F2). Access should be made FU-34955 by qualified service technicians only.
  • Page 35 Stainless steel door without manual door lock 5018250 5018251 5018252 5018253 5018254 Seismic Mounting Brackets Note: special installation requirements apply 1014403 1014403 1014403 1014403 1017494 Stacking Hardware - DC250 or DC350 double stacked White Epoxy Coated — 5013021 5013021 — — — 5017272 5017272 — —...
  • Page 36 Service Part numbers and drawings are subject to change without notice. Full Assembly A Item Description Part Item Description Part Side cover, 1.5 1011024 Rear cover, stainless steel, 1.5 1014262 Side cover, stainless steel, 1.5 1014261 Rear cover, 2.5 3 5013521 Side cover, 2.5 1011269...
  • Page 37 Service Part numbers and drawings are subject to change without notice. Full Assembly B Item Description Part Blanket support bottom, 1.5 1011045 Blanket support bottom, 2.5 1011265 Blanket support bottom, 3.5 1011265 Blanket support bottom, 4.0 1011471 Blanket support bottom, 7.5 1011471 Blanket support side, 1.5 1012865...
  • Page 38 Service Part numbers and drawings are subject to change without notice. Full Assembly C 16 16 16 14 16 13 Item Description Part Item Description Part Chassis, 3-zone, 120V, 1.5 /2.5 5017792 Spring, door, 1.5 SD-29340 Chassis, 3-zone, 230V, 1.5 /2.5 5017795 Spring, door, 2.5...
  • Page 39 Service Part numbers and drawings are subject to change without notice. Electrical Chassis Item Description Part Power supply, 20W, 5 volt DC BA-34965 Relay board, 3-zone, 120V, 1.5ft /2.5ft BA-35106 Relay board, 4-zone, 120V, 3.5ft /4.0ft /7.5ft BA-35107 Relay board, 3-zone, 230V, 1.5ft /2.5ft BA-35109 Relay board, 4-zone, 230V, 3.5ft...
  • Page 40 Service Part numbers and drawings are subject to change without notice. Door Latch & Sensor Item Description Part Plate, latch pull, 1.5 1011197 Plate, latch pull, 2.5 /4.0 1011263 Plate, latch pull, 3.5 1011295 Plate, latch pull, 7.5 1011850 Guide, low profile rail, 1.5 GI-29204 Guide, low profile rail, 2.5 /3.5...
  • Page 41 Service Part numbers and drawings are subject to change without notice. Control Interface Item Description Part Panel, interface mount, 18.5", 1.5 /2.5 /3.5 1011336 Panel, interface mount, 24", 4.0 /7.5 1011482 Panel, front top trim, painted, 18.5", 1.5 /2.5 /3.5 1011032 Panel, front top trim, painted, 24", 4.0 /7.5...
  • Page 42 Service Part numbers and drawings are subject to change without notice. Shelf (DC350/DC750 only) Item Description Part Panel, heated shelf bottom, 3.5 1011230 Panel, heated shelf bottom, 7.5 1011597 Panel, heated shelf, 3.5 1015078 Panel, heated shelf, 7.5 1014609 Heated shelf kit, 3.5 5017020 Heated shelf kit, 7.5 5019545...
  • Page 43: Wiring Diagrams

    Wiring Diagrams Refer to wire diagram included with the appliance. MN-37072 • Rev 2 • 05/16 • Designer Series Blanket Warmer...
  • Page 44 Enthermics Medical Systems An ISO 13485:2003 certified company PO Box 443, Menomonee Falls WI 53052-0443 W164 N9221 Water St, Menomonee Falls WI 53051 Tel 262-251-8356 | 800-TO-B-WARM generalinfo@enthermics.com www.enthermics.com Printed in the U.S.A. Specifications are Subject to Change Without Notice...