  • Page 1 BELVEDERE 18 ENGLISH Pellet boiler Main Revision 1.4 FPH_supplement: 001 stove INSTALLATION, USE AND MAINTENANCE, USEFUL TIPS Applies to: BV16 BV16-V (with room fan)
  • Page 3 Ref. Annex III EU Regulation no. 305/2011 DoP/KLOVER-028 Identification number : DVU Model and/or lot no. and/or serial no. (Art.11-4) : DIVA UTILITY – BELVEDERE 18 Intended use of the product according to the relevant Home heating appliance fed with wood harmonised technical specification pellets KLOVER s.r.l.
  • Page 4: Table Of Contents

    CONTENTS CONTENTS ..................................1 INTRODUCTION ................................. 4 MPORTANT SAFETY INSTRUCTIONS .................................. NSTALLATION EGULATIONS ..................................... CO A LARMS ..........................................ONTROL OF UBSTANCES AZARDOUS TO EALTH ..........................XTRACT VENTILATION ......................................EARTH ............................................ ISTANCE TO COMBUSTIBLES.................................. OMBUSTION AIR SUPPLY ....................................ONNECTION TO THE CENTRAL HEATING SYSTEM ............................LECTRICAL CONNECTIONS ....................................
  • Page 5 AINTENANCE ........................................... PCB PARAMETERS ................................. 36 WIRING DIAGRAM ................................38 WARRANTY CONDITIONS .............................. 39...
  • Page 6 BELVEDERE 18 PELLET BOILER STOVE Dear Customer, First of all we would like to thank you for choosing a “KLOVER” product and we hope you will be satisfied with this product. Please read the warranty certificate carefully. This is found on the last page of this User Guide. Please contact the authorised Technical Assistance Centre (TAC) for the initial start-up of your stove and to validate the warranty.
  • Page 7: Introduction

    - The Klover pellet products are not suitable for use in smokeless zones. KLOVER S.R.L. DECLINES ALL LIABILITY IN CASE OF ACCIDENTS DUE TO FAILURE TO COMPLY WITH THE SPECIFICATIONS OF THIS MANUAL.
  • Page 8: Installation Regulations

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE EXTERNAL AIR VENT AND THE CORRECTNESS OF THE PROPOSED INSTALLATION SOLUTIONS. ALL THE SAFETY REGULATIONS SET OUT IN THE SPECIFIC LAWS IN FORCE IN THE COUNTRY OF THE STOVE'S INSTALLATION MUST BE OBSERVED.
  • Page 9: Distance To Combustibles

    Health and Safety Care must be taken when installing a Klover pellet appliance to ensure that the requirements of the Health and Safety at Work Act are met. Adequate Handling facilities must be available for loading, unloading and site handling the appliance bearing in mind the...
  • Page 10: The Machine And The Pellets

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE THE MACHINE AND THE PELLETS Components of the appliance The table below shows the standard features of the appliance: Expansion tank Safety valve 2.5 bar 0 – 4 bar Pressure gauge...
  • Page 11 EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE Terminal for room thermostat connection. REAR TECHNICAL COMPARTMENT Safety thermostat with manual reset. Anti-interference filter Main switch, connection for power supply cable with 2 built-in fuses (4A 250V). Combustion air inlet.
  • Page 12: Overall Dimensions

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE Overall dimensions...
  • Page 13: Connections Data Sheet

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE Connections data sheet REAR VIEW Description of connections M = Heating system flow 3/4" F R = Heating system return 3/4" M X = Safety valve drain 1/2" F A = Combustion air inlet...
  • Page 14: Technical Specifications

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE Technical Specifications Nominal heat input kW (Kcal/h) 20,9 (18.000) Reduced thermal capacity kW (Kcal/h) 5,4 (4.600) Nominal thermal output kW (Kcal/h) 18,4 (15.800) Reduced thermal power kW (Kcal/h) 4,9 (4.200) Nominal power released to heating water kW (Kcal/h) 13,9 (12.000)
  • Page 15: Pellet Properties

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE Pellet properties The appliance has been tested with all types of pellets available on the market. The pellets must have the following properties: - Diameter 6 mm. - Maximum length 35 mm.
  • Page 16: Spaces Around And Above The Appliance

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE The unit must be installed on a floor with a suitable load capacity. If the existing building does not fulfil this requirement appropriate measures (e.g. load distribution plate) must be taken.
  • Page 17: The Flue Pipe And Connection To The Same

    Fig. A Chimney and Flue pipe The chimney is essential to the efficient operation of a Klover appliance. The chimney should be designed and constructed according to these instructions, and relevant regulations including Building Regulations Approved Document Shape and size of chimney: A round chimney of 125mm diameter is recommended. 125mm is also the minimum diameter which should be used.
  • Page 18 EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE Orientation and initial vertical rise: The flue system should run as vertically as possible as any deviations off the vertical can adversely affect the draw. 45º is the maximum off-vertical angle than may be used. Non-vertical sections should make up no more than ¼...
  • Page 19: Chimney

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE Height and draught: In order for the appliance to perform satisfactorily the chimney height must be sufficient to ensure a draught of 12 Pa so as to clear the products of combustion and prevent smoke problems into the room.
  • Page 20: Electrical Connection

    Do not pass electric cables in the immediate vicinity of the flue gas pipe, unless they are insulated with suitable materials. KLOVER srl declines all responsibility for injury to persons and animals or damage to objects due to failure to connect the appliance to earth or to comply with IEC specifications.
  • Page 21: Connection To The Room Thermostat

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE Connection to the room thermostat On the back of the appliance there is a bridged terminal which is used to connect the environment thermostat that will command the operation. OPERATING PRINCIPLE Open contact: - The appliance switches directly to economy mode operation “T-OFF ECONOMY”...
  • Page 22: The Display

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE In the event of water with hardness exceeding 28 °f, an anti-limescale device must be installed. This must be selected on the basis of the specific properties of the water. The appliance must be mounted exclusively by qualified personnel. Scrupulously comply with the instructions given in this guide.
  • Page 23 EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE The following figure describes the meanings of the status signals appearing on the display left side (1st LED SERIES). ROOM THERMOSTAT: the LED is on when the thermostat contact is open.
  • Page 24: The Menu

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE The table explains how the buttons on the display work. DESCRIPTION MODE ACTION Programming mode.. Changes/increases the value of the selected menu item. Increase temperature (1) Working/off.. It increases the temperature of the room/water thermostat.
  • Page 25 EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE Menu 02 – Set chrono Sub-menu 02 – 01 – Enable chrono Allows you to globally enable and disable all programmable thermostat functions. For the correct operation it is recommended to enable it (“ON”) when at least one on/off programme (daily, weekly or weekend programme) is activated.
  • Page 26 EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE PROGRAM 3 MENU LEVEL SELECTION MEANING POSSIBLE VALUES 02 – 03 – 20 Time – OFF START PROG-3 Turn-on time of the third programme 02 – 03 – 21 Time – OFF...
  • Page 27 (detected with KLOVER “Remote control”) is reached..to control the appliance with both the KLOVER “Remote control” room temperature and the boiler thermostat: - enable the room sensor on the “Remote control” (Stove settings menu +> Enable room sensor -> ON) - enable the boiler thermostat contact on the display of the appliance (Menu 4 - Enable contact ->...
  • Page 28: Initial Start-Up

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE Summary: MENU 04 – ENABLE R.T. REMOTE CONTROL CASE ACTION ROOM SENSOR CONTACT It works with room thermostat contact. It works with room thermostat contact. It works with remote control room sensor only.
  • Page 29: Pellet Loading And Connection To The Mains Power Supply

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE The system and the water inside the boiler can be emptied by opening the “boiler body and system drain cock” situated at the back of the appliance. In intensely cold periods it is good practice to leave the heating system running. In the event of a prolonged absence, anti-freeze must be added to the heating water or the system must be completely emptied.
  • Page 30: Working Mode

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE Working mode During the working phase, by pressing 1, you can set the “SET H2O” (maximum water temperature in the boiler). When this temperature is reached, the appliance enters economy mode operation “T-H2O ECONOMY”.
  • Page 31: Changing The Air Fan Speed (On The Bv16-V Model Only)

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE - Room Temperature (used only in case of the “Remote control” connection) To modify the ambient temperature, simply select “SET ROOM TEMP” by pressing button 2. Now use buttons 1 and 2.
  • Page 32: Problems, Alarms, Useful Advices

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE PROBLEMS, ALARMS, USEFUL ADVICES Useful info… Listed below is some important information regarding the appliance: - It is normal for the appliance to emit a smell of paint during its first few days of operation. We recommend ventilating the installation room during the initial start-up.
  • Page 33: Alarm Signals

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE If the outage lasts longer than Pr48, when power is restored, the appliance will enter the “STOP FIRE” (stand-by) mode running the entire switch-off cycle until cooling. When this phase is over, the appliance can be restarted resuming work at the set power.
  • Page 34: Cleaning And Maintenance

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE CLEANING AND MAINTENANCE Precautions before cleaning Before carrying out any cleaning or maintenance operations, make sure that: - the appliance is off and has cooled down completely; - the ash is completely cold.
  • Page 35: Non-Routine Cleaning

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE Thoroughly clean the brazier from combustion residues by taking it out from its position and removing any residues inside (Figure Use a suitable ash vacuum device to remove any ash deposited under the brazier...
  • Page 36 EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE Clean the pipes inside the combustion chamber using the supplied brush and passing it repeatedly between one and the other pipe (Figure To remove any deposits, it is also recommended that you scrape the inner walls of the combustion chamber with a spatula.
  • Page 37 EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE Remove the front panel below (Figure 8). The front panel is fixed to the frame with two magnets; to remove it, just pull it towards you. After unscrewing the hand-wheels, extract the side flue gas pass inspection vent (Figure 9).
  • Page 38: Cleaning The Ceramic Glass

    You must periodically check the seals because the latter guarantee the air- and water-tightness of the appliance and its good functioning; if they are worn or damaged you need to be replace them immediately by contacting a Klover Authorised technical assistance centre.
  • Page 39: Pcb Parameters

    The following parameters are already stored during the testing of the appliance directly in the factory; these parameters are the result of special tests using several types of pellets and must not be changed without the authorisation of Klover srl so as not to impair the operation of the appliance.
  • Page 40 EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE THRESHOL M – 9 – 6 – 14 110 – 250 Pr14 Flue gas maximum temperature °C MAXIMUM Flue gas temperature threshold for starting the BLOWER M – 9 – 6 – 15 50 –...
  • Page 41: Wiring Diagram

    EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE WIRING DIAGRAM Earth PCB L023 FUSE 4A 5X20 TRANSFORMER FLUE GAS PHASE EXTRACTOR WITH Mains 230Vac NEUTRAL TACHOMETER CENTRIFUGAL WARM AIR FANS (OPTIONAL) DISSIPATOR IGNITION RELAY IGNITION HEATING ELEMENT DISPLAY CONNECTOR...
  • Page 42: Warranty Conditions

    - A copy of the initial start-up report issued by the Authorised Technical Assistance Centre must be preserved along with the proof of purchase receipt. - KLOVER s.r.l. disclaims any liability for accidents resulting from failure to comply with the instructions contained the user and maintenance manual attached to the appliance.
  • Page 43 EN - Rev. 1.4 BELVEDERE 18 PELLET BOILER STOVE...
  • Page 44 Cod. CS.IST.BV16-EN.FP KLOVER Srl Via A. Volta, 8 37047 San Bonifacio (VR) VAT No. 02324280235 www.klover.it...