Page 1
STAR 14 Pellet ENGLISH boiler stove INSTALLATION, USE AND MAINTENANCE, USEFUL TIPS...
Page 3
Ref. Annex III EU Regulation no. 305/2011 DoP/KLOVER-007 Identification number : ST14 Model and/or lot no. and/or serial no. (Art.11-4) : STAR 14 Intended use of the product according to the relevant Home heating appliance fed with wood harmonised technical specification pellets KLOVER s.r.l.
CONTENTS CONTENTS ..................................1 INTRODUCTION ................................. 3 ........................... 3 MPORTANT SAFETY INSTRUCTIONS ............................4 NSTALLATION EGULATIONS ................................ 4 EALTH AND AFETY THE MACHINE AND THE PELLETS ..........................4 ............................. 4 OMPONENTS OF THE APPLIANCE ..............................6 VERALL DIMENSIONS .............................. 7 ONNECTIONS DATA SHEET .............................
Page 5
EN - Rev. 2.1 Dear Customer, First of all we would like to thank you for choosing a “KLOVER” product and we hope you will be satisfied with this product. Please read the warranty certificate carefully. This is found on the last page of this User Guide. Please contact the authorised Technical Assistance Centre (TAC) for the initial start-up of your stove and to validate the warranty.
- The Klover pellet products are not suitable for use in smokeless zones. KLOVER S.R.L. DECLINES ALL LIABILITY IN CASE OF ACCIDENTS DUE TO FAILURE TO COMPLY WITH THE SPECIFICATIONS OF THIS MANUAL.
Approved Document J. Health and Safety Care must be taken when installing a Klover pellet appliance to ensure that the requirements of the Health and Safety at Work Act are met. Handling Adequate facilities must be available for loading, unloading and site handling the appliance bearing in mind the weight of the appliance.
Page 8
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 TOP TECHNICAL COMPARTMENT Manometer (indicates the pressure Manual air vent valve of the heating system). (with key and rubber pipe). Anti-interference filter Main switch, connection for power supply cable with 2 built-in fuses (4A 250V).
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 Connections data sheet REAR VIEW Description of connections M = System Delivery 3/4" F R = System Return 3/4" M X = Safety valve drain 1/2" F A = Intake pipe...
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 Pellet properties The appliance has been tested with all types of pellets available on the market. The pellets must have the following properties: - Diameter 6 mm. - Maximum length 35 mm.
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 The unit must be installed on a floor with a suitable load capacity. If the existing building does not fulfil this requirement appropriate measures (e.g. load distribution plate) must be taken.
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 Do not connect the external air vent directly to the appliance through piping. If there are other heating or extraction devices inside the room, the air vents must guarantee a sufficient amount of air for properly operating all the devices.
Page 15
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 - It is forbidden to allow other air intake conduits and system pipes to transit inside the flue gas pipes, even if they are over-sized. FURTHER SPECIFICATIONS TO BE CONSIDERED - The appliance works with the combustion chamber in depression and the flue pipe in pressure; it is essential that the flue gas outlet is hermetically sealed.
Do not pass electric cables in the immediate vicinity of the flue gas pipe, unless they are insulated with suitable materials. KLOVER srl declines all responsibility for injury to persons and animals or damage to objects due to failure to connect the appliance to earth or to comply with IEC specifications.
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 Control of any coupled boiler If the pellet appliance is to be coupled with a previously installed boiler in the system (e.g. wall-hung gas boiler), you must ensure that the standard boiler stops when the pellet appliance takes over the heating of the system. The electrical...
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 Connection to the room thermostat On the back of the appliance there is a bridged terminal which is used to connect the environment thermostat that will command the operation. OPERATING PRINCIPLE Open contact: - The appliance switches directly to economy mode operation “T-OFF ECONOMY”...
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 In the event of water with hardness exceeding 28 °f, an anti-limescale device must be installed. This must be selected on the basis of the specific properties of the water. The appliance must be mounted exclusively by qualified personnel. Scrupulously comply with the instructions given in this guide.
Page 20
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 The following figure describes the meanings of the status signals appearing on the display left side (1st LED SERIES). ROOM THERMOSTAT: the LED is on when the thermostat contact is open.
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 The table explains how the buttons on the display work. DESCRIPTION MODE ACTION Programming mode.. Changes/increases the value of the selected menu item. Increase temperature (1) Working/off.. It increases the temperature of the room/water thermostat.
Page 22
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 Menu 02 – Set chrono Sub-menu 02 – 01 – Enable chrono Allows you to globally enable and disable all programmable thermostat functions. For the correct operation it is recommended to enable it (“ON”) when at least one on/off programme (daily, weekly or weekend programme) is activated.
Page 23
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 PROGRAM 3 MENU LEVEL SELECTION MEANING POSSIBLE VALUES 02 – 03 – 20 START PROG-3 Turn-on time of the third programme Time – OFF 02 – 03 – 21 STOP PROG-3 Turn-off time of the third programme Time –...
Page 24
(detected with KLOVER “Remote control”) is reached..to control the appliance with both the KLOVER “Remote control” room temperature and the boiler thermostat: - enable the room sensor on the “Remote control” (Stove settings menu +> Enable room sensor -> ON) - enable the boiler thermostat contact on the display of the appliance (Menu 4 - Enable contact ->...
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 Summary: REMOTE CONTROL MENU 04 – ENABLE R.T. CASE ACTION ROOM SENSOR CONTACT It works with room thermostat contact. It works with room thermostat contact. It works with remote control room sensor only.
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 The system and the water inside the boiler can be emptied by opening the “boiler body and system drain cock” situated at the back of the appliance. In intensely cold periods it is good practice to leave the heating system running. In the event of a prolonged absence, anti-freeze must be added to the heating water or the system must be completely emptied.
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 Working mode During the working phase, by pressing 1, you can set the “SET H2O” (maximum water temperature in the boiler). When this temperature is reached, the appliance enters economy mode operation “T-H2O ECONOMY”.
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 - Room Temperature (used only in case of the “Remote control” connection) To modify the ambient temperature, simply select “SET ROOM TEMP” by pressing button 2. Now use buttons 1 and 2.
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 PROBLEMS, ALARMS, USEFUL ADVICES Useful info… Listed below is some important information regarding the appliance: - It is normal for the appliance to emit a smell of paint during its first few days of operation. We recommend ventilating the installation room during the initial start-up.
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 If the outage lasts longer than Pr48, when power is restored, the appliance will enter the “STOP FIRE” (stand-by) mode running the entire switch-off cycle until cooling. When this phase is over, the appliance can be restarted resuming work at the set power.
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 CLEANING AND MAINTENANCE Precautions before cleaning Before carrying out any cleaning or maintenance operations, make sure that: - the appliance is off and has cooled down completely; - the ash is completely cold.
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 Thoroughly clean the brazier from combustion residues by taking it out from its position and removing any residues inside (Figure Use a suitable ash vacuum device to remove any ash deposited under the brazier...
Page 33
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 Dismount the 4 flue diverters (2 on the right and 2 on the left) placed on the combustion chamber sides (figure 6 e 7) scrape the internal walls with a spatula removing any deposit...
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 Clean the pipes inside the combustion chamber using the supplied brush and passing it repeatedly between one and the other pipe (Figure To remove any deposits, it is also recommended that you scrape the inner walls of the combustion chamber with a spatula.
You must periodically check the seals because the latter guarantee the air- and water-tightness of the appliance and its good functioning; if they are worn or damaged you need to be replace them immediately by contacting a Klover Authorised technical assistance centre.
The following parameters are already stored during the testing of the appliance directly in the factory; these parameters are the result of special tests using several types of pellets and must not be changed without the authorisation of Klover srl so as not to impair the operation of the appliance.
Page 37
STAR 14 PELLET BOILER STOVE EN - Rev. 2.1 THRESHOL Pr14 M – 9 – 6 – 14 Flue gas maximum temperature °C 110 – 250 MAXIMUM Flue gas temperature threshold for starting the Pr15 M – 9 – 6 – 15 BLOWER THRESHOL °C...
- A copy of the initial start-up report issued by the Authorised Technical Assistance Centre must be preserved along with the proof of purchase receipt. - KLOVER s.r.l. disclaims any liability for accidents resulting from failure to comply with the instructions contained the user and maintenance manual attached to the appliance.
Page 40
Cod. CS.IST.ST14-EN.FP KLOVER Srl Via A. Volta, 8 37047 San Bonifacio (VR) P.IVA 02324280235 www.klover.it...
Need help?
Do you have a question about the STAR 14 and is the answer not in the manual?
Questions and answers