CONTENTS CONTENTS ..................................1 INTRODUCTION ................................. 3 ........................... 3 MPORTANT SAFETY INSTRUCTIONS THE MACHINE AND THE PELLETS ..........................4 ............................. 4 OMPONENTS OF THE APPLIANCE ..............................7 VERALL DIMENSIONS .............................. 8 ONNECTIONS DATA SHEET ................................ 9 ELLET PROPERTIES REQUIREMENTS OF THE PLACE OF INSTALLATION ....................10 ..................................
Page 4
STANDARD WARRANTY CONDITIONS ......................... 45 Dear client, First of all we would like to thank you for choosing a “KLOVER” product and we hope you will be satisfied with this product. Carefully read the warranty certificate on the last page of this User guide.
- The appliance’s installation and initial start-up must be performed by skilled personnel trained in the relevant safety standards, who are responsible for the definitive installation of the appliance and its efficient operation. KLOVER Srl shall not be held liable if these precautions are not observed.
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 KLOVER S.R.L. DECLINES ALL LIABILITY IN CASE OF ACCIDENTS DUE TO FAILURE TO COMPLY WITH THE SPECIFICATIONS OF THIS MANUAL. KLOVER S.R.L. DECLINES ALL LIABILITY DUE TO INCORRECT USE OF THE PRODUCT BY THE USER, UNAUTHORISED MODIFICATION AND/OR REPAIRS, AND USE OF NON-ORIGINAL SPARE PARTS OR SPARE PARTS NOT SPECIFICALLY DESIGNED FOR USE ON THIS PRODUCT MODEL.
Page 7
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 FRONT VIEW Rod for cleaning the CE label front heat exchanger. with technical data, serial number and model. Flue pressure switch. Flue gas extractor. Control unit. Inspection Port Inspection Port flue gas extractor lower flue gas passage.
Page 8
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 TOP VIEW Bracket Inspection Port for fixing on wall. left side flue gas passage. Inspection Port right side flue gas passage. REAR VIEW Bracket for fixing on wall. Pre-configuration for ducted air outlet.
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 Connections data sheet REAR VIEW Description of connections A = Intake pipe 50 mm Cn1u = Upper ducted air outlet (only on configured models) 80 mm M Cn1b = Rear ducted air outlet (only on configured models)
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 Pellet properties The appliance has been tested with all types of pellets available on the market. The pellets must have the following properties: - Diameter 6 mm. - Maximum length 35 mm.
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 REQUIREMENTS OF THE PLACE OF INSTALLATION Positioning The initial phase for best installation of the appliance is to determine its optimum location; the following elements need to be considered: - The possibility of creating an external air vent;...
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 Spaces around and above the appliance The figure below shows the minimum distances from walls or other not-easily-removable furniture, that need to be taken into consideration when positioning the appliance. REAR WALL Any shelves or false ceilings mounted above the appliance must be at least 75 cm away from the top part of it.
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 The flue and connection to the same The flue is an essential element for the efficient operation of the appliance. The flue must have the minimum cross- sectional dimensions stated in the appliance’s technical specifications (80 mm). Each product must be equipped with its own flue, without other adjoining elements (boilers, chimneys, stoves, etc.).
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 Ø 80 mm 80 mm INSPECTION INSPECTION Ø 80 mm If the flue is old or too large (internal diameter greater than 15 cm), it must be ducted using a stainless steel pipe that is suitably insulated (with rock wool or vermiculite) and sized according to the route.
Do not pass electric cables in the immediate vicinity of the flue gas pipe, unless they are insulated with suitable materials. KLOVER Srl declines all responsibility for injury to persons and animals or damage to objects due to failure to connect the appliance to earth or to comply with IEC specifications.
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 Connection to the room thermostat or to a room probe One or more terminal blocks are located behind the appliance to connect any room thermostats or probes (refer to “Components of the appliance”).
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 DESCRIPTION OF COMPONENTS Remote control Display Button 1 – INCREASE Button 5 – ESC Button 2 – DECREASE Button 4 – SET Button 3 – ON/OFF The remote control must be powered by 3 x 1.5 V AAA batteries (model LR03 / MN2400); the battery life depends on how frequently the remote control is used.
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 Support panel LED 6 – WI-FI LED 4 – RECEPTION LED 5 – ALARM LED 3 – POWER STATUS Button 2 – POWER LED 2 – POWER STATUS Serial connection for remote control LED 1 –...
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 The support panel allows for managing the basic functions concerning the appliance’s operation when there is no remote control. The following operations can therefore be carried out: - SWITCHING ON/OFF: by pressing and holding button 1 (On/Off) for 2 seconds - WORKING POWER CHANGE: whenever button 2 (Power) is pressed, the working power can be varied by selecting one of the three available power levels (1, 3 or 5).
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 THE MENU Pressing button 4 (Set) of the remote control allows for accessing the menu. The menu is divided into different items and levels, providing access to the programming and settings options of the appliance.
Page 22
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 The image below shows the display when the timer is enabled: Enable field Sub-menu 02 – 02 – Daily chrono Allows for enabling, disabling and setting the daily programme functions.
Page 23
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 Sub-menu 02 – 03 – Weekly chrono Allows for enabling, disabling and setting the weekly timer functions. The weekly timer has four time slots delimited by the set times, as shown in the following diagram (they do not have to...
Page 24
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 Switch-on time (OFF signals to the clock to ignore the command) Enable field (It must be enabled if at least one time slot is active) SET OUTPUT (Working power in the selected...
Page 25
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 Menu 05 – Settings It allows you to regulate the various remote control settings. The table below indicates the settings with the relevant meaning: Menu Meaning Settable values * BOARD BEEPS Enables/disables the beep sound on the power board ON –...
Page 26
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 ALARM DELAY In the event of an alarm, it indicates the time (in seconds) after which the alarm appears on the display. T.MOTHERBOARD Indicates the temperature measured by the probe inside the control unit.
Page 27
3%. * Unauthorised access can cause serious damage to equipment, objects and the environment, as well as personal injuries. Klover declines all responsibility deriving from improper calibration of these values. Menu 10 – Technical calibration Allows you to access all data reserved for the Technical Assistance Centre.
Connection to the Wi-Fi network The appliance is equipped with a Wi-Fi board that enables it to be remotely controlled via the “My Klover” Web app, which can be downloaded to smartphones, tablets or PCs from various stores (Apple, Android, etc.).
Page 29
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 6. A new page will open up (Welcome to WiFiMi Setup) containing all the data relative to the previous configuration. To reconnect the module to the indicated network, go to “Menu 08 – WIFI STATUS” of the remote control, select “RESET”...
Page 30
(Apple, Android, etc.). 11. Return to the home page of the “My Klover” app and access your account by entering the credentials (e-mail address and password) previously used for the registration phase. You can now add a new appliance by clicking in the “Add stove”...
12. At this point, the appliance will be added and can be managed through the Web app from any device (PC / tablet / smartphone) connected to the Internet. It can be accessed from the address http://appwifi.klover.it/it/ or via the “My KLOVER” app, which can be downloaded from various stores (Apple, Android, etc). START-UP Initial start-up Perform the following operations: - Connect the appliance to the electrical system by using the provided cable;...
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 If the ignition fails, the display will show the “FAILED IGNITION” alarm. The alarm may also occur if the brazier is dirty; in this case, clean the brazier and re-start. Warning: during the ignition phase and normal operation of the appliance, maintain the necessary safety distance and do not stand in front of it.
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 During the work phase, the appliance enters the “MODULATION” economy mode when this temperature value is reached (see “Work phase”). Modifying the power set-point - To modify the working power, simply select “SET OUTPUT” by pressing button 2 (Decrease).
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 PROBLEMS, ALARMS, USEFUL TIPS Useful info… Listed below is some important information regarding the appliance: - It is normal for the appliance to emit a smell of paint during its first few days of operation. We recommend ventilating the installation room thoroughly during the initial start-up.
Every alarm causes the appliance to switch-off immediately. The alarm status is reached after the time set on Pr11 (set by default to 90 sec) and can be reset by pressing and holding button 3. In case of anomalies, contact the Klover authorised Technical Assistance Centre.
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 CLEANING AND MAINTENANCE Precautions before cleaning Before carrying out any cleaning or maintenance operations, make sure that: - the appliance is off and has cooled down completely; - the ash is completely cold.
Page 37
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 Use the appropriate cleaning hook for the front scraper to pull out the front rod and then move it forward and backwards to clean off combustion residues from the air exchanger...
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 Empty the ash box (Figure Non-routine cleaning The extraordinary cleaning of the appliance must be done at least every 30 days so as to always guarantee efficient performance and optimal operation.
Page 39
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 Clean the right and left side flue gas passages using a brush (figure Remove the inspection port of the lower flue gas passage by undoing the two screws (figure 9). After removing the...
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 To ensure correct operation, it is necessary to remove the sawdust deposited on the bottom of the tank (Figure 13) least once every 30 days. The pellet tank must be emptied at the end of every season.
You must periodically check the seals because the latter guarantee the air- and water-tightness of the appliance and its good functioning; if they are worn or damaged you need to be replace them immediately by contacting a Klover Authorised technical assistance centre.
The following parameters are already stored during the testing of the appliance directly in the factory; these parameters are the result of special tests using several types of pellets and must not be changed without the authorisation of Klover srl so as not to impair the operation of the appliance.
Page 43
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 Parameters “DEFAULT SETTINGS” - Mod. DSA (L15_181119) Database Parameter Menu level Description Display Measurement Value field Pr01 M10 – 05 – 01 Ignition cycle maximum time START TIME Minutes 5 – 25 Pr02 M10 –...
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 Parameter tables DIVA SLIM MULTI-AIR “CLEANER SETTINGS” parameters - Model DSC (L15_181119) Database Parameter Menu level Description Display Measurement Value field Pr51 M10 – 01 – 01 ON time for brazier cleaning gear motor...
Page 45
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 Parameters “DEFAULT SETTINGS” - Mod. DSC (L15_181119) Database Parameter Menu level Description Display Measurement Value field Pr01 M10 – 05 – 01 Ignition cycle maximum time START TIME Minutes 5 – 25 Pr02 M10 –...
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0 WIRING DIAGRAM COMPONENT LEGEND: SAFETY DEVICE KEY: LEGENDA COMPONENTI: LEGENDA DISPOSITIVI DI SICUREZZA: M1 = screw feeder gear motor M1 = Motoriduttore coclea ALp = Micro chiusura porta fuoco ALp = Fire door closure micro switch...
The Klover Warranty will remain in effect for a period of 2 years from the date of purchase, if proven by a delivery note or other proof of purchase (e.g. receipt), stating the name of the seller, the product that was bought, and the date of purchase.
Page 48
Klover Products must undergo functional testing before any related masonry works are carried out (for example before tiling, installation of pilasters, or painting of the walls). Klover Srl is not liable for any costs incurred as a result of removal and/or reconstruction of related installations, or for any other ancillary intervention even if it is the result of works to replace defective parts.
Page 49
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0...
Page 50
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0...
Page 51
DIVA SLIM AIR PELLET STOVE EN - Rev. 1.0...
Page 52
Code CS.IST.DSA-EN KLOVER Srl Via A. Volta, 8 37047 San Bonifacio (VR) VAT No. 02324280235 www.klover.it...
Need help?
Do you have a question about the DIVA SLIM AIR and is the answer not in the manual?
Questions and answers