A.
STAND-ALONE CONTROLLER TEST FAILURES-
FAILING MODULE - DISK CONTROLLER
B.
STATUS ERRORS
MODE
UNIT
i
DATA
STARTING DISK ADDRESS
CYL
i
HEAD
SECTOR
i
ACl(STATUS) SHOULD =ACO
DESCRIPTIONS OF FAILING STATUS BITS
PROBABLE FAILING MODULES -(AS PER EACH FAILING BIT)
C •
MEMORY/DISK ADDRESS ERROR
MODE
UNIT
i
DATA
STARTING DISK ADDRESS
CYL
i
HEAD
i
SECTOR
i
ENDING MEMORY/DISK ADDRESS ERR.OR
ACl (MA/DA) SHOULD =ACO
D. INTERRUPT TIMEOUT
MODE
UNIT
i
DATA
STARTING DISK ADDRESS
CYL
i
HEAD
i
SECTOR
i
INTERRUPT TIMEOUT
Figure 4-22.
Model 6234 Sample Error Report
CAUTION
Replacing the data module or reformatting the disks in the
data module will destroy all stored data.
When you receive a failing FRU (module) report, replace one FRU at a
time and rerun the diagnostic program.
If the diagnostic fails after
replacing one FRU, reinstall the original FRU and then replace the other
FRU called out by the error report and try again.
Ref er to Section 5 for
replacement procedures.
If the medium is called out as a failing module, try reformatting
before replacing the data module.
Additional test significance can be found in the program listing,
although it is hoped that a need for the listing will be minimal. SWPACK
(SWREG) provides all control over test loop options and printouts.
015-000133
4-35