Data General Corporation (DGC) has prepared this manual for use by DGC personnel and customers as a guide to the proper installation, operation, and
maintenance of DGC equipment and software. The drawings and specifications contained herein are the property of DGC and shall neither be reproduced in
whole or in part without DGC's prior written approval nor be implied to grant any license to make, use, or sell equipment manufactured in accordance herewith.
4.7.6
Diagnostic Error Reports - Detailed error and command summary
information is printed on detection of an error.
Additionally, tests
that perform error checking issue a "probable failing FRO" report.
This
report identifies the first, second, third, and sometimes fourth most
likely failing FRO for the detected error; e.g., controller PCB, media,
read/write and clock PCB.
The error report gives the operator
information such as:
The last command
The last address issued before failure detection
Status information down to the bit level.
For a detected error, the program prints the error PC, AC
O,
1, and
2 at the point of error, plus an option printout.
The program then
goes into a scope loop between entries to .SETUP and .LOOP allowing the
operator to set SWPAK.
In general the error PC points to a call error.
The option printout is done in one of the formats shown in Figure
4-24.
NOTE
The diagnostic program may or may not call out the correct
failing FRO.
Further investigation may still be required
by referencing and then performing the procedure given in
the diagnostic flowcharts (refer to subsection 4.2)
015-000133