Data General NOVA ECLIPSE 6234 Service Manual page 136

Table of Contents

Advertisement

Data General Corporation (OGC) has prepared this manual for use by OGC personnel and customers as a guide to the proper installation, operation, and
maintenance of DGC equipment and software. The drawings and specifications contained herein are the property of OGC and shall neither be reproduced in
whole or in part without OGC's prior written approval nor
be
implied to grant any license to make, use. or sell equipment manufactured in accordance herewith.
4.
Place the plastic locking arm onto the locked pin.
The plastic
locking arm is located under the bottom cover near the front of
the drive (see Figure 5-16).
FS-05885
Pigure 5-16.
Sealed Data Module, Plastic Locking Arm
PLASTIC
LOCKING
ARM
5.
Place the locking arm lever back onto the unlocked pin.
Only
Stepper phase LED QA will be on (see Figure 5-17).
6.
Reconnect the connector at J4 on the power supply PCB.
NOTE
The heads are now positioned over track 192 (300
octal).
To verify the alignment only, omit steps
7 and 8 and proceed to step 9.
5-18