Data General NOVA ECLIPSE 6234 Service Manual page 49

Table of Contents

Advertisement

Data General Corporation (DGC) has prepared this manual for use by DGC personnel and customers as a guide to the proper installation, operation, and
maintenance of DGC equipment and software. The drawings and specifications contained herein are the property of DGC and shall neither be reproduced in
whole or in part without DGC's prior written approval nor be implied to grant any license to make. use, or sell equipment manufactured in accordance herewith .
START
POWER UP
THE
SUBSYSTEM
FS-05831A
ENSURE THAT
ALL CONNECTORS
ARE SECURE
RUN
DIAGNOSTICS
GOTO
FIGURE 4-9
GOTO
RELAY CHECK
REPLACE THE
POWER SUPPLY
PCB (SUBSECTION 5.5)
REPLACE
CONTROLLER
(SUBSECTION 5.1)
GOTO
READ/WRITE AND
CLOCK PCB
CHECK
NOT A DISK
SUBSYSTEM
PROBLEM
CAUTION:
ETCHES ON THE AC DISTRIBUTION
PCB ARE EXPOSED TO 120 OR 240 VOL TS AC.
BE CAREFUL
Figure 4-4.
Master Troubleshooting Flowchart for
Model 6234/6280
015-000133
4-4