    Please observe the necessary national and European standards and local regulations. Please observe the fire regulations of your country. In case of doubt, check the valid conditions for the operation of fireplaces in your local area. Subject to technical changes! User Manual Urfeuer 4free (1.9) © 2023 Brunner GmbH...
  • Page 3: Basics

    When wood with closed cell structure (spruce, fir, pine) is burned in an open fireplace, then it is necessary to close the spark mesh for protection. © 2023 Brunner GmbH User Manual Urfeuer 4free (1.9)
  • Page 4: Precautionary Statements

    The external surfaces are getting hot. Do not touch - risk of burns! Remember to warn your children about this. Basically, children should stay away from a burning stove. For operation use always the attached operating tool! User Manual Urfeuer 4free (1.9) © 2023 Brunner GmbH...
  • Page 5 Only cold ashes should be removed from the fireplace; store the ashes in a fire-resistant container for at least 24 hours before disposal. Glowing embers can be found in ashes for a very long time. © 2023 Brunner GmbH User Manual Urfeuer 4free (1.9)
  • Page 6 Spilling out embers To prevent spilling out of embers, use the provided protection strip when the Urfeuer fireplace is in use. The fireplace can be used only under supervision! User Manual Urfeuer 4free (1.9) © 2023 Brunner GmbH...
  • Page 7: Firewood And Heating Power

    Natural firewood (left) is the best fuel for fireplaces, but you can use also wood briquettes according to DIN 17225-3, Class A1, length >14 cm (5.51 in), diameter >8 cm (3.15 in) (right). © 2023 Brunner GmbH User Manual Urfeuer 4free (1.9)
  • Page 8 Adjusting the heat by reducing the volume of combustion air is wrong! If there is not enough combustion air available, the energy contained in fire- wood cannot be completely released. At the same time, the emissions are rising due to unburned particles. User Manual Urfeuer 4free (1.9) © 2023 Brunner GmbH...
  • Page 9 Firewood volumes Fireplace Load volume Log length Log circumfer- ence Urfeuer 4free 2,0 kg - 5,0 25 cm - 50 cm 20 cm - 30 cm © 2023 Brunner GmbH User Manual Urfeuer 4free (1.9)
  • Page 10: Instruction For Use

    Hardwood is usually burning more calm and evenly. Firewood is placed crosswise at the rear wall in center of the Urfeuer fire- place (see picture). With a fire starter placed underneath (e.g. BRUNNER Fidibus), the fire will advance very quickly.
  • Page 11: Shut-Off Flap Operation

    SHUT-OFF FLAP OPERATION Shut-off flap in closed position. Close the shut- off flap only af- ter completled combustion! Im. 1: Flue gas closed © 2023 Brunner GmbH User Manual Urfeuer 4free (1.9)
  • Page 12: Closing Spark Protection Mesh

    Im. 2: Flue gas open CLOSING SPARK PROTECTION MESH To prevent the glowing embers from falling out, keep the spark protection mesh closed during combustion! User Manual Urfeuer 4free (1.9) © 2023 Brunner GmbH...
  • Page 13 Im. 3: Spark mesh © 2023 Brunner GmbH User Manual Urfeuer 4free (1.9)
  • Page 14: Use Of The Soot Box

    The soot box is sim- ply clipped and can be mounted or removed with light pressure. User Manual Urfeuer 4free (1.9) © 2023 Brunner GmbH...
  • Page 15: Note

    User Guide. It is necessary to follow any other relevant instructions, like the “Operating instructions for tiled stove water boilers”! My stove fitting company: © 2023 Brunner GmbH User Manual Urfeuer 4free (1.9)
  • Page 16: Disposal

    Zellhuber Ring 17-18 misprints reserved. D-84307 Eggenfelden Reprinting and reproduction, even in part, only with Tel.: +49 (0) 8721/771-0 / Fax: +49 (0) 8721/771-100 the express permission of the publisher. Email: info@brunner.de Art.Nr.: User Manual Urfeuer 4free (1.9) © 2023 Brunner GmbH...