Summary of Contents for Brunner Urfeuer 50/110

  • Page 1 User Manual Urfeuer 50/110 ©2024...
  • Page 2: Table Of Contents

    Please keep the User Guide for future reference! Waste on fire = Toxins in your garden We suggest to perform registration of your product. (www.produktregistrierung.brunner.de). BASICS Proper function of a fireplace depends on the volume of combustion air streaming into the room. Sufficient air supply must be ensured before fire is lit.
  • Page 3: Precautionary Statements

    Between the surfaces of the stove casings from ceramic tiles or plaster and flammable mate- rials, a minimal distance of 5 cm must be kept. This distance must allow for air circulation. A much greater distance must be kept from fireplace surfaces made of metal. © 2024 Brunner GmbH (1.9)
  • Page 4 The functionality and the safe operation of the fireplace depend on regular cleaning and prop- er maintenance. Spilling out embers To prevent spilling out of embers, use the provided protection strip when the Urfeuer fireplace is in use. The fireplace can be used only under supervision! (1.9) © 2024 Brunner GmbH...
  • Page 5: Firewood And Heating Power

    500 kg x 3,3 kWh/kg = 1650 kWh 1 cubic meter dry wood Water content 15% 500 kg x 4,1 kWh/kg = 2050 kWh What amount of heat will I get when buying wood per volume (1 cubic meter = 1 m3)? © 2024 Brunner GmbH (1.9)
  • Page 6: Instructions For Use

    The firewood should be stored for at least one year in airy and dry conditions. Most suitable for use in open fireplaces are all types of hardwood, like oak, beech or birch. (1.9) © 2024 Brunner GmbH...
  • Page 7 Firewood is placed crosswise at the rear wall in center of the Urfeuer fireplace (see picture). With a fire starter placed underneath (e.g. BRUNNER Fidibus), the fire will advance very quickly. During reloading, the wood logs must not be laid very close to the edge of the combustion chamber opening, but on the existing area of glowing embers.
  • Page 8: Installation Of The Ember Retaining Bar

    INSTALLATION OF THE EMBER RETAINING BAR D022045 (1.9) © 2024 Brunner GmbH...
  • Page 9: Shut-Off Flap Operation

    Shut-off flap in open position. Keep the shut-off flap open during combustion! CLOSING SPARK PROTECTION MESH To prevent the glowing embers from falling out, keep the spark protection mesh closed during combustion! © 2024 Brunner GmbH (1.9)
  • Page 10: Note

    The warranty expires if the device has not been used as intended. Intended use includes reading and follow- ing the instructions of this User Guide. It is necessary to follow any other relevant instructions, like the “Operating instructions for tiled stove water boilers”! My stove fitting company: (1.9) © 2024 Brunner GmbH...
  • Page 11: Disposal

    Technical and assortment changes as well as errors and Zellhuber Ring 17-18 misprints reserved. Reprinting and reproduction, even in part, only with D-84307 Eggenfelden the express permission of the publisher. Tel.: +49 (0) 8721/771-0 / Fax: +49 (0) 8721/771-100 Email: info@brunner.de Art.Nr.: 200239 © 2024 Brunner GmbH (1.9)