Led Indicator - Goodwe MIS Series Quick Installation Manual

Micro inverter
Hide thumbs Also See for MIS Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
GoodWe Technologies Co., Ltd. hereby declares that the inverter without wireless
communication modules sold in the European market meets the requirements of the following
directives:
• Electromagnetic compatibility Directive 2014/30/EU (EMC)
• Electrical Apparatus Low Voltage Directive 2014/35/EU (LVD)
• Restrictions of Hazardous Substances Directive 2011/65/EU and (EU) 2015/863 (RoHS)
• Waste Electrical and Electronic Equipment 2012/19/EU
• Registration, Evaluation, Authorization and Restriction of Chemicals (EC) No 1907/2006
(REACH)
You can download the EU Declaration of Conformity on

LED Indicator

Indicator Status
Explanation
Slow blinking green = Equipment power on and in the standby mode.
Fast blinking green = Equipment starting and in the self-check mode.
Steady green = The four PV inputs are available, and the inverter is
feeding power to the grid properly.
Blinking green and red = Not all PV inputs are available, but the inverter
is still feeding power to the grid.
The four blinks represent the status of four inputs PV1, PV2, PV3 and
PV4 respectively. Red blinks indicating abnormal PV input, green blinks
indicating normal PV input.
Example: As shown on the left, PV1 is abnormal and PV2, PV3 and PV4
are normally working.
Single blinking red = Utility grid loss.
Double blinking red = Utility grid fault.
Steady red = Equipment fault.
Fast blinking green and red = Updating software.
https://en.goodwe.com.
03
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gw1600-misGw1800-misGw2000-mis

Table of Contents