Whale SDA074T Quick Connect Manual page 15

Whale sense flood reduction and water saving device
Table of Contents

Advertisement

(Fig 9.A) Sika Sensor & Solenoids Connection
+
+
(Fig 10.A) Settings for Sika Sensor & Retractive Switch
1 2 3 4 5 6 7 10 30 60 1 2
S 1
J4
J5
+
+
P 2
1. The Whale Sense unit should be installed in an accessible location within 7 meters of the transformer.
Fig 8. shows the Whale Sense in the area above the bathroom i.e. loft space.
2. To transmit the flow information for the mixer shower either flow sensors or flow switches may be used.
The advantage of a flow sensor is that the pump speed will automatically adjust to the flow rate of the shower. For
connections for a Sika Sensor (SDS263T) see Fig 9.A and for connection for a Whale flow switch (AK1568) see Fig 9.B.
3. The corresponding settings for a flow sensor and a flow switch on the Whale Instant Match transformer are shown in
Fig 10.A and Fig 10.B. When using a Whale flow switch (AK1568), the speed of the pump should be manually matched
with the flow rate of the shower. Move the blue jumper on the Instant Match transformer to increase or decrease the pump
speed as required.
4. Pairing of Whale Sense to Whale Instant Match
A. When first powered on, the Whale Sense and Instant Match transformer will flash red indicating it is unpaired.
B. To place Whale Sense in pairing mode, press and HOLD the blue test button and wait for the LED to flash red/green,
indicating pairing mode. NOTE: You have 120 seconds to pair the Whale Sense to the transformer.
C. Press and HOLD the blue test button on the transformer and wait for the LED to flash red/green, indicating pairing mode.
D. You will hear 3 audible beeps and the transformer will flash green only to indicate successful pairing with the Whale Sense.
E. The LED on the Whale Sense will also flash green showing paired state.
5. Unpairing Whale Sense and Whale Instant Match
A . On Whale Instant Match transformer, remove the red jumper from the 'pipe diameter' setting.
B. Press and HOLD the blue test button and wait for an audible beep indicating unpairing is complete.
C. The LED on the Instant Match transformer will flash red indicating it is unpaired.
D. The LED on the Whale Sense will flash red to indicate it is unpaired. Replace the red jumper.
6. Paired but 'no power' on Whale Sense
A. If the Instant Match transformer and Whale Sense are paired but power is not switched on to the Whale Sense then
the LED on Instant Match transformer will flash blue every 10 seconds.
7. Retractive Switch Connection to Instant Match transformer - (Opens the solenoids or activates the pump)
A. A retractive switch may be installed to enable the user of the shower to activate the pump or open the solenoids for
a 30 minute pre-set time.
B. Momentarily pressing the retractive switch opens the solenoids for a pre-set period of 30 minutes.
C. Pressing and holding the retractive switch for > 1 second forces the pump to run without having to turn on the shower.
Whale Sense Settings
Whale Instant Match Transformer Settings
J6
P 1
+
(Fig 9.B) Flow Switch & Solenoid Connection
+
+
(Fig 10.B) Settings for Flow Switch & Retractive Switch
1 2 3 4 5 6 7 10 30 60 1 2
S 1
J4
J5
+
+
P 2
J6
P 1
+