Page 2
Printing, spelling and typographical errors reserved. The information in this document is subject to change without prior notice and should not be construed as a commitment by Austroflamm GmbH. Austroflamm GmbH assumes no responsibility for any errors that may appear in this document.
Operating manual Fynn Xtra Contents Contents General information ............................Copyright.............................. Information about the document ...................... Purpose of the manual............................Storing the manual ..........................Structure of the manual........................Representations used.......................... Version control ............................. Abbreviations ............................Safety..................................Importance of the safety instructions ....................
Page 4
Contents Operating manual Fynn Xtra 9.1.1 Rearranging the flue pipe connection at the rear ................25 9.1.2 Rearranging the balanced flue at the rear (without base).............. 27 9.1.3 Rearranging the balanced flue at the bottom (without base) ............28 9.1.4 Rearranging the balanced flue at the rear (with base)..............
Information about the document The information in this document is subject to change without prior notice and should not be con- strued as a commitment by Austroflamm GmbH. Austroflamm GmbH assumes no responsibility for any errors that may appear in this document.
Operating manual Fynn Xtra 2 | Purpose of the manual Purpose of the manual This manual is a component part of the stove and is intended to contribute to the stove being safely in- stalled and maintained. Please read this manual before using the stove for the first time.
2 | Purpose of the manual Operating manual Fynn Xtra Version control We update our manuals on a continual basis. The current version can be found at our homepage www.austroflamm.com. Abbreviations Abbreviation Meaning Heat Memory System Stoves...
• Before operating your stove, carefully read through the entire manual and observe the instructions and warnings. • Austroflamm GmbH accepts no liability or responsibility for the connection of our heating appli- ances to shared exhaust pipes/chimneys – multiple occupancy. For more information consult a chimney sweep and check your national, regional and local building regulations.
3 | Safety Operating manual Fynn Xtra • Please note that the surfaces of this stove heat up considerably during operation. We recommend that you use the protective glove supplied to operate your stove. • Please alert children to these dangers, and keep them away from the stove when it is operating.
Operating manual Fynn Xtra 4 | Product overview Product overview Intended use The Austroflamm stove described in this manual is manufactured and tested according to EN13240. NOTICE Operation is only permissible with closed/bolted door. Identification of the product In the following illustrations we give an overview of the most important dimensions and the nameplate positioning.
4 | Product overview Operating manual Fynn Xtra Energy label -80% Austrof amm Fynn Xtra -60% -40% -20% ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE · ENERGI 2015/1186 Fig. 3: Energy label Positioning of the type plate Here we show where you can find the type plate.
Operating manual Fynn Xtra 5 | Technical data Technical data A connection to a chimney already occupied with other solid-fuel stoves and ovens is possible provided that the chimney rating under DIN 4705 – part 3, does not contravene this.
Page 14
5 | Technical data Operating manual Fynn Xtra Particular precautions for assembly, installation or maintenance Described in the individual sections of the operating manual. Fuel Preferred Other suit- Space heating emis- Space heating emis- ηs fuel able fuel(s) [x%]: sions at nominal heating...
Page 15
Operating manual Fynn Xtra 5 | Technical data Properties for exclusive operation with the preferred fuels Specification Symbol Value Unit Specification Symbol Value Unit Heat output Thermal efficiency (fuel efficiency) (based on the NCV) Nominal heat effi- Pnom Thermal efficiency (fuel ef- 81.0...
Operating manual Fynn Xtra 6 | Transport, handling and storage Transport, handling and storage Transportation Every Austroflamm stove is packed for protection and envir- onmental friendliness. The packaging consists of: • The pallet, • crate and • protective film. 1) The packaging consists of untreated local wood or materials.
6 | Transport, handling and storage Operating manual Fynn Xtra Transport aid NOTICE It is vital that the transport aid be removed before installing the appliance! Only approved transport aids with sufficient load-bearing capacity may be used for transport. These must be removed before installation.
Safety distances to be observed If your floor is made of a combustible material, a non-combustible material must be used as protection in the area in front of the appliance. For more detailed information, please contact an Austroflamm dealer. NOTICE A floor protection plate must be used if your floor is made from a combustible material.
When connecting the flue pipes to the chimney, national and/or local safety regulations must be com- plied with. Your Austroflamm stove is fitted at the factory with a flue pipe outlet at the top (see chapter Technical data). The connection can, as described in these instructions, be rearranged to the bottom.
Operating manual Fynn Xtra 8 | Fuel material/-quantity Fuel material/-quantity Fuel Wood Many of our native types of wood can, after being appropriately dried, be burnt CO2-neutral in heat- producing appliances. Wood stands out because it grows again, can be sustainably harvested, re- quires little or no extra external energy to be invested in the fuel, and has a short journey from the pro- ducer to the consumer, which provides an optimal climate balance.
Page 22
8 | Fuel material/-quantity Operating manual Fynn Xtra Please observe at all times the maximum specified amount to be laid, even when putting on more wood! Otherwise your fire will not provide the desired efficiency - but above all considerable damage may be caused to your appliance, to gaskets and material and to the flue gas duct.
Maximum amount of fuel to be deposited: 1.7 kg logs. NOTICE Overheating Too great a quantity of fuel can lead to overheating and damage to your Austroflamm stove NOTICE To avoid damage you must NEVER operate your Stove a greater quantity of fuel than that specified in...
9 | Installation Operating manual Fynn Xtra Installation Installation must only be carried out by an authorized specialist company. Before installing the stove, check that all movable parts are working. Any defects must be reported be- fore the installation. In the following sections we will give you information on •...
Operating manual Fynn Xtra 9 | Installation Execution 9.1.1 Rearranging the flue pipe connection at the rear 1) First the cover must be removed and the side clad- ding detached. Proceed as described in the section Removing the side cladding [}on page 60].
Page 26
9 | Installation Operating manual Fynn Xtra 5) Replace parts and reinstall. Fig. 10: Replacing cover and bracket Fig. 11: Cover and bracket replaced 6) Mount side cladding and trim at top and bottom and attach cover. Fig. 12: Mounting the side cladding...
Operating manual Fynn Xtra 9 | Installation 9.1.2 Rearranging the balanced flue at the rear (without base) 1) First the cover must be removed and the side clad- ding detached. Proceed as described in the section Removing the side cladding [}on page 60].
9 | Installation Operating manual Fynn Xtra 9.1.3 Rearranging the balanced flue at the bottom (without base) 1) First the cover must be removed and the side clad- ding detached. Proceed as described in the section Removing the side cladding [}on page 60].
Operating manual Fynn Xtra 9 | Installation 9.1.4 Rearranging the balanced flue at the rear (with base) 1) First the cover must be removed and the side clad- ding detached. Proceed as described in the section Removing the side cladding [}on page 60].
Page 30
9 | Installation Operating manual Fynn Xtra 5) Mount an aluminium flexible pipe and place the stove on to the base. 6) Pull out the aluminium flexible pipe backward. Fig. 21: Placing the stove on to the base 7) Mount side cladding and trim and attach cover.
Operating manual Fynn Xtra 9 | Installation 9.1.5 Rearranging the balanced flue at the bottom (with base) 1) First the cover must be removed and the side clad- ding detached. Proceed as described in the section Removing the side cladding [}on page 60].
Page 32
9 | Installation Operating manual Fynn Xtra 5) Mount a pipe at the bottom and place the stove on to the base. Fig. 26: Placing the stove on to the base 6) Mount side cladding and trim and attach cover. Fig. 27: Mounting the side cladding...
Operating manual Fynn Xtra 9 | Installation 9.1.6 Mounting the trim at the top 1) Remove cover. Fig. 28: Removing the cover 2) Undo screws. Fig. 29: Loosening the screws 3) Attach trim and fasten with the screws. 4) If the trim does not sit properly, the trim must be ad- justed.
9 | Installation Operating manual Fynn Xtra 9.1.7 Mounting the trim at the bottom 1) Open the door. Fig. 31: Open the door 2) First attach the trim to the stove at the bottom and hang it at the top. 3) If the trim does not sit properly, the trim must be ad- justed.
Operating manual Fynn Xtra 9 | Installation 9.1.8 Installing the turntable without base 1) Remove cover. Fig. 33: Removing the cover 2) Remove flue pipe bracket. Fig. 34: Removing the flue pipe bracket...
Page 36
9 | Installation Operating manual Fynn Xtra 3) Install rotary flue pipe bracket. Fig. 35: Installing the rotary flue pipe bracket 4) Using two people, tilt the stove backward. 5) Slide turntable under the stove. Fig. 36: Tilting the stove If the turntable’s control lever is raised, then the turntable is unlocked and the stove can be turned.
Operating manual Fynn Xtra 9 | Installation 9.1.9 Installing the turntable (RLU dm130) without base 1) First the cover must be removed and the side clad- ding detached. Proceed as described in the section Removing the side cladding [}on page 60].
Page 38
9 | Installation Operating manual Fynn Xtra 4) Using two people, tilt the stove backward. 5) Slide turntable under the stove. 6) Reattach rear panel and cover. Fig. 40: Tilting the stove 7) Fasten turntable to stove. Fig. 41: Fastening turntable to stove If the turntable’s control lever is raised, then the turntable is...
Operating manual Fynn Xtra 9 | Installation 9.1.10 Installing the turntable with base 1) Repeat the first three steps from the section Installing the turntable without base [}on page 35]. 2) Place the stove on to the base. 3) Using two people, tilt the stove backward.
Page 40
9 | Installation Operating manual Fynn Xtra 3) Install rotary flue pipe bracket. Fig. 45: Installing the rotary flue pipe bracket 4) Place stove on to the base and carefully tilt it slightly backward. 5) Slide turntable under the stove. Fig. 46: Tilting the stove on the base...
Page 41
Operating manual Fynn Xtra 9 | Installation 6) Fasten turntable to stove. Fig. 47: Fastening turntable to stove 7) Mount side cladding and trim and attach cover. Fig. 48: Mounting the side cladding...
9 | Installation Operating manual Fynn Xtra 9.1.12 Fitting the base 1) Place stove on to the base and fix the base to the stove from below. Fig. 49: Fitting the base from below 9.1.13 Installing Keramott Numbering = installation sequence...
Operating manual Fynn Xtra 10 | Settings Settings 10.1 Adjusting the trim at the top If the top trim does not sit properly, it can be adjusted as follows. • 1) If these screws are loosened, the position of the fa- cing can be laterally adjusted (left + right).
10 | Settings Operating manual Fynn Xtra In addition the trim can also be adjusted. To do so, please proceed as follows: 3) Detach the trim again (if mounted). 4) There are two screws on the trim. Using these screws the position of the trim can be adjusted upwards or downwards.
Operating manual Fynn Xtra 10 | Settings 10.4 Adjusting the door lock 1) First the cover must be removed and the side clad- ding detached. Proceed as described in the section Removing the side cladding [}on page 60]. 2) Open the door.
10 | Settings Operating manual Fynn Xtra 4) The closing force can be adjusted by loosening or tightening the threaded bolt (1). Fig. 58: Position B 10.5 Tensioning/relaxing the door spring 1) First the cover must be removed and the side clad- ding detached.
Operating manual Fynn Xtra 10 | Settings 10.6 Adjusting the turntable This turntable can be operated even with the firebox doors closed. If the turntable’s control lever is raised, then the turntable is unlocked and the stove can be turned. If on the other hand...
11 | Commissioning Operating manual Fynn Xtra Commissioning 11.1 Initial Commissioning NOTICE During the initial commissioning and in the following 2-3 combustion cycles, only approx. 2/3 of the maximum fuel quantity is to be used. NOTICE To avoid damage you must NEVER operate your Stove a greater quantity of fuel than that specified in this manual! During the first 3-4 combustion cycles at nominal heat output, odors may develop.
Operating manual Fynn Xtra 12 | Operation Operation 12.1 Before heating up The stove can only function properly if there is sufficient combustion air coming to the room of installa- tion (the appliance), specially if several firing installations are being operated at the same time. Ensure sufficient air supply before heating up.
12 | Operation Operating manual Fynn Xtra 7) Close the door. ð It is best to allow the first layer of wood to combust without altering the air damper setting. ð If only the bed of embers is left (no more flames), you can place another layer of log.
14 | Cleaning Operating manual Fynn Xtra Cleaning 14.1 Cleaning the stove, flue gas ducts and flue pipe The stove, the flue gas ducts and flues should be annually - possible even more often, e.g. • after the chimney has been cleaned •...
Page 53
Operating manual Fynn Xtra 14 | Cleaning 1) Open the door. 2) Raise the grate with the attached hook. Fig. 65: Raising the grate 3) Take the cover provided and use it to cover the ash box. 4) Turn the handle of the cover clockwise until the handle engages.
During cleaning and maintenance, the glass must also be cleaned. If it is not regularly cleaned then the soot particles may end up being burned in. This makes regular maintenance all the more important. • We recommend cleaning the glass with our Austroflamm glass cleaner or a commercially available window cleaner.
Operating manual Fynn Xtra 15 | Help Help Problem Cause Solution The glass window is sooty Insufficient draft from time to time (depending on use) the window must be cleaned with glass cleaner Clarification with chimney sweeper (poss. extend chimney/measure...
15 | Help Operating manual Fynn Xtra Problem Cause Solution Operating temperature not reached Bring stove to the operating temper- ature Sooting up of the window after 8- 10 hours of fires is normal Chimney draft too low Contact chimney sweep 15.1 Firebox lining...
Operating manual Fynn Xtra 16 | Accessories Accessories Have defective parts (accessories, spare parts) replaced by your specialist stove dealer. This guaran- tees that stove is and remains safe and functional.
Operating manual Fynn Xtra 17 | Spare parts Spare parts Spare parts can be ordered through our dealers. For ordering spare parts, it is necessary to provide the type plate picture or data from the type plate of your stove. This guarantees proper spare parts for your specific stove.
18 | Disassembling Operating manual Fynn Xtra Disassembling For correct uninstallation and dismantling of the stove, contact your Austroflamm specialist dealer. 18.1 Removing side cladding 1) Remove cover. Fig. 68: Removing the cover 2) Loosen the screws of the front top trim and detach trim.
Page 61
Operating manual Fynn Xtra 18 | Disassembling 3) Open door and detach bottom trim. Fig. 70: Open the door 4) Loosen the marked screws left and right. Fig. 71: Undoing the screws 5) Lift up and detach the side cladding. Fig. 72: Detaching the side cladding...
NOTICE For correct uninstallation and dismantling of the stove, contact your Austroflamm specialist dealer. Electric and electronic components Remove the electric and electronic components from the appliance by dismounting them. These com- ponents must not be disposed of via non-recyclable waste.
Page 63
Operating manual Fynn Xtra 19 | Disposal Handles and decorative elements made of metal If present, disassemble or remove handles and decorative elements made of metal and dispose of as metal scrap. Local disposal options must be observed.
For the replaceability of the warranty case the start-up log must be received by Austroflamm within one month at the latest of the initial commissioning. In or- der to make a claim on the warranty, repairs to your stove must only be carried out by a service en- gineer authorized by Austroflamm.
Operating manual Fynn Xtra 21 | Start-up log Start-up log Operator / Customer Dealer / Engineer Name Company Street Street Town and postal code Town and postal code Telephone Telephone Email Email Stove Working Comments Model Serial number Technology Visuals...
Need help?
Do you have a question about the Fynn Xtra and is the answer not in the manual?
Questions and answers