  • Page 1 Operating manual Fynn Xtra www.austroflamm.com...
  • Page 2 Printing, spelling and typographical errors reserved. The information in this document is subject to change without prior notice and should not be construed as a commitment by Austroflamm GmbH. Austroflamm GmbH assumes no responsibility for any errors that may appear in this document.
  • Page 3: Table Of Contents

    Operating manual Fynn Xtra Contents Contents General information ............................Copyright.............................. Information about the document ...................... Purpose of the manual............................Storing the manual ..........................Structure of the manual........................Representations used.......................... Version control ............................. Abbreviations ............................Safety..................................Importance of the safety instructions ....................
  • Page 4 Contents Operating manual Fynn Xtra 9.1.1 Rearranging the flue pipe connection at the rear ................25 9.1.2 Rearranging the balanced flue at the rear (without base).............. 27 9.1.3 Rearranging the balanced flue at the bottom (without base) ............28 9.1.4 Rearranging the balanced flue at the rear (with base)..............
  • Page 5 Operating manual Fynn Xtra Contents 21 Start-up log................................65 22 Service Report ..............................66...
  • Page 6: General Information

    Information about the document The information in this document is subject to change without prior notice and should not be con- strued as a commitment by Austroflamm GmbH. Austroflamm GmbH assumes no responsibility for any errors that may appear in this document.
  • Page 7: Purpose Of The Manual

    Operating manual Fynn Xtra 2 | Purpose of the manual Purpose of the manual This manual is a component part of the stove and is intended to contribute to the stove being safely in- stalled and maintained. Please read this manual before using the stove for the first time.
  • Page 8: Version Control

    2 | Purpose of the manual Operating manual Fynn Xtra Version control We update our manuals on a continual basis. The current version can be found at our homepage www.austroflamm.com. Abbreviations Abbreviation Meaning Heat Memory System Stoves...
  • Page 9: Safety

    • Before operating your stove, carefully read through the entire manual and observe the instructions and warnings. • Austroflamm GmbH accepts no liability or responsibility for the connection of our heating appli- ances to shared exhaust pipes/chimneys – multiple occupancy. For more information consult a chimney sweep and check your national, regional and local building regulations.
  • Page 10: Special Types Of Danger And Personal Protective Equipment

    3 | Safety Operating manual Fynn Xtra • Please note that the surfaces of this stove heat up considerably during operation. We recommend that you use the protective glove supplied to operate your stove. • Please alert children to these dangers, and keep them away from the stove when it is operating.
  • Page 11: Product Overview

    Operating manual Fynn Xtra 4 | Product overview Product overview Intended use The Austroflamm stove described in this manual is manufactured and tested according to EN13240. NOTICE Operation is only permissible with closed/bolted door. Identification of the product In the following illustrations we give an overview of the most important dimensions and the nameplate positioning.
  • Page 12: Energy Label

    4 | Product overview Operating manual Fynn Xtra Energy label -80% Austrof amm Fynn Xtra -60% -40% -20% ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE · ENERGI 2015/1186 Fig. 3: Energy label Positioning of the type plate Here we show where you can find the type plate.
  • Page 13: Technical Data

    Operating manual Fynn Xtra 5 | Technical data Technical data A connection to a chimney already occupied with other solid-fuel stoves and ovens is possible provided that the chimney rating under DIN 4705 – part 3, does not contravene this.
  • Page 14 5 | Technical data Operating manual Fynn Xtra Particular precautions for assembly, installation or maintenance Described in the individual sections of the operating manual. Fuel Preferred Other suit- Space heating emis- Space heating emis- ηs fuel able fuel(s) [x%]: sions at nominal heating...
  • Page 15 Operating manual Fynn Xtra 5 | Technical data Properties for exclusive operation with the preferred fuels Specification Symbol Value Unit Specification Symbol Value Unit Heat output Thermal efficiency (fuel efficiency) (based on the NCV) Nominal heat effi- Pnom Thermal efficiency (fuel ef- 81.0...
  • Page 16: General Specifications

    Baking compartment depth [mm] Warming drawer, width [mm] Warming compartment height [mm] Warming drawer, depth [mm] Dimensions, a (with Austroflamm elbow piece) [mm] 1645 Dimensions, b (with Austroflamm elbow piece) [mm] Dimensions, c (with Austroflamm elbow piece) [mm] Dimensions, d (with Austroflamm elbow piece) [mm] Flue pipe outlet, diameter [mm] Outside air connection diameter [Ø mm]...
  • Page 17: Transport, Handling And Storage

    Operating manual Fynn Xtra 6 | Transport, handling and storage Transport, handling and storage Transportation Every Austroflamm stove is packed for protection and envir- onmental friendliness. The packaging consists of: • The pallet, • crate and • protective film. 1) The packaging consists of untreated local wood or materials.
  • Page 18: Transport Aid

    6 | Transport, handling and storage Operating manual Fynn Xtra Transport aid NOTICE It is vital that the transport aid be removed before installing the appliance! Only approved transport aids with sufficient load-bearing capacity may be used for transport. These must be removed before installation.
  • Page 19: Requirements At The Installation Location

    Safety distances to be observed If your floor is made of a combustible material, a non-combustible material must be used as protection in the area in front of the appliance. For more detailed information, please contact an Austroflamm dealer. NOTICE A floor protection plate must be used if your floor is made from a combustible material.
  • Page 20: Combustion Air

    When connecting the flue pipes to the chimney, national and/or local safety regulations must be com- plied with. Your Austroflamm stove is fitted at the factory with a flue pipe outlet at the top (see chapter Technical data). The connection can, as described in these instructions, be rearranged to the bottom.
  • Page 21: Fuel Material/-Quantity

    Operating manual Fynn Xtra 8 | Fuel material/-quantity Fuel material/-quantity Fuel Wood Many of our native types of wood can, after being appropriately dried, be burnt CO2-neutral in heat- producing appliances. Wood stands out because it grows again, can be sustainably harvested, re- quires little or no extra external energy to be invested in the fuel, and has a short journey from the pro- ducer to the consumer, which provides an optimal climate balance.
  • Page 22 8 | Fuel material/-quantity Operating manual Fynn Xtra Please observe at all times the maximum specified amount to be laid, even when putting on more wood! Otherwise your fire will not provide the desired efficiency - but above all considerable damage may be caused to your appliance, to gaskets and material and to the flue gas duct.
  • Page 23: Fuel Quantity

    Maximum amount of fuel to be deposited: 1.7 kg logs. NOTICE Overheating Too great a quantity of fuel can lead to overheating and damage to your Austroflamm stove NOTICE To avoid damage you must NEVER operate your Stove a greater quantity of fuel than that specified in...
  • Page 24: Installation

    9 | Installation Operating manual Fynn Xtra Installation Installation must only be carried out by an authorized specialist company. Before installing the stove, check that all movable parts are working. Any defects must be reported be- fore the installation. In the following sections we will give you information on •...
  • Page 25: Execution

    Operating manual Fynn Xtra 9 | Installation Execution 9.1.1 Rearranging the flue pipe connection at the rear 1) First the cover must be removed and the side clad- ding detached. Proceed as described in the section Removing the side cladding [}on page 60].
  • Page 26 9 | Installation Operating manual Fynn Xtra 5) Replace parts and reinstall. Fig. 10: Replacing cover and bracket Fig. 11: Cover and bracket replaced 6) Mount side cladding and trim at top and bottom and attach cover. Fig. 12: Mounting the side cladding...
  • Page 27: Rearranging The Balanced Flue At The Rear (Without Base)

    Operating manual Fynn Xtra 9 | Installation 9.1.2 Rearranging the balanced flue at the rear (without base) 1) First the cover must be removed and the side clad- ding detached. Proceed as described in the section Removing the side cladding [}on page 60].
  • Page 28: Rearranging The Balanced Flue At The Bottom (Without Base)

    9 | Installation Operating manual Fynn Xtra 9.1.3 Rearranging the balanced flue at the bottom (without base) 1) First the cover must be removed and the side clad- ding detached. Proceed as described in the section Removing the side cladding [}on page 60].
  • Page 29: Rearranging The Balanced Flue At The Rear (With Base)

    Operating manual Fynn Xtra 9 | Installation 9.1.4 Rearranging the balanced flue at the rear (with base) 1) First the cover must be removed and the side clad- ding detached. Proceed as described in the section Removing the side cladding [}on page 60].
  • Page 30 9 | Installation Operating manual Fynn Xtra 5) Mount an aluminium flexible pipe and place the stove on to the base. 6) Pull out the aluminium flexible pipe backward. Fig. 21: Placing the stove on to the base 7) Mount side cladding and trim and attach cover.
  • Page 31: Rearranging The Balanced Flue At The Bottom (With Base)

    Operating manual Fynn Xtra 9 | Installation 9.1.5 Rearranging the balanced flue at the bottom (with base) 1) First the cover must be removed and the side clad- ding detached. Proceed as described in the section Removing the side cladding [}on page 60].
  • Page 32 9 | Installation Operating manual Fynn Xtra 5) Mount a pipe at the bottom and place the stove on to the base. Fig. 26: Placing the stove on to the base 6) Mount side cladding and trim and attach cover. Fig. 27: Mounting the side cladding...
  • Page 33: Mounting The Trim At The Top

    Operating manual Fynn Xtra 9 | Installation 9.1.6 Mounting the trim at the top 1) Remove cover. Fig. 28: Removing the cover 2) Undo screws. Fig. 29: Loosening the screws 3) Attach trim and fasten with the screws. 4) If the trim does not sit properly, the trim must be ad- justed.
  • Page 34: Mounting The Trim At The Bottom

    9 | Installation Operating manual Fynn Xtra 9.1.7 Mounting the trim at the bottom 1) Open the door. Fig. 31: Open the door 2) First attach the trim to the stove at the bottom and hang it at the top. 3) If the trim does not sit properly, the trim must be ad- justed.
  • Page 35: Installing The Turntable Without Base

    Operating manual Fynn Xtra 9 | Installation 9.1.8 Installing the turntable without base 1) Remove cover. Fig. 33: Removing the cover 2) Remove flue pipe bracket. Fig. 34: Removing the flue pipe bracket...
  • Page 36 9 | Installation Operating manual Fynn Xtra 3) Install rotary flue pipe bracket. Fig. 35: Installing the rotary flue pipe bracket 4) Using two people, tilt the stove backward. 5) Slide turntable under the stove. Fig. 36: Tilting the stove If the turntable’s control lever is raised, then the turntable is unlocked and the stove can be turned.
  • Page 37: Installing The Turntable (Rlu Dm130) Without Base

    Operating manual Fynn Xtra 9 | Installation 9.1.9 Installing the turntable (RLU dm130) without base 1) First the cover must be removed and the side clad- ding detached. Proceed as described in the section Removing the side cladding [}on page 60].
  • Page 38 9 | Installation Operating manual Fynn Xtra 4) Using two people, tilt the stove backward. 5) Slide turntable under the stove. 6) Reattach rear panel and cover. Fig. 40: Tilting the stove 7) Fasten turntable to stove. Fig. 41: Fastening turntable to stove If the turntable’s control lever is raised, then the turntable is...
  • Page 39: Installing The Turntable With Base

    Operating manual Fynn Xtra 9 | Installation 9.1.10 Installing the turntable with base 1) Repeat the first three steps from the section Installing the turntable without base [}on page 35]. 2) Place the stove on to the base. 3) Using two people, tilt the stove backward.
  • Page 40 9 | Installation Operating manual Fynn Xtra 3) Install rotary flue pipe bracket. Fig. 45: Installing the rotary flue pipe bracket 4) Place stove on to the base and carefully tilt it slightly backward. 5) Slide turntable under the stove. Fig. 46: Tilting the stove on the base...
  • Page 41 Operating manual Fynn Xtra 9 | Installation 6) Fasten turntable to stove. Fig. 47: Fastening turntable to stove 7) Mount side cladding and trim and attach cover. Fig. 48: Mounting the side cladding...
  • Page 42: Fitting The Base

    9 | Installation Operating manual Fynn Xtra 9.1.12 Fitting the base 1) Place stove on to the base and fix the base to the stove from below. Fig. 49: Fitting the base from below 9.1.13 Installing Keramott Numbering = installation sequence...
  • Page 43: Settings

    Operating manual Fynn Xtra 10 | Settings Settings 10.1 Adjusting the trim at the top If the top trim does not sit properly, it can be adjusted as follows. • 1) If these screws are loosened, the position of the fa- cing can be laterally adjusted (left + right).
  • Page 44: Adjusting The Door

    10 | Settings Operating manual Fynn Xtra In addition the trim can also be adjusted. To do so, please proceed as follows: 3) Detach the trim again (if mounted). 4) There are two screws on the trim. Using these screws the position of the trim can be adjusted upwards or downwards.
  • Page 45: Adjusting The Door Lock

    Operating manual Fynn Xtra 10 | Settings 10.4 Adjusting the door lock 1) First the cover must be removed and the side clad- ding detached. Proceed as described in the section Removing the side cladding [}on page 60]. 2) Open the door.
  • Page 46: Tensioning/Relaxing The Door Spring

    10 | Settings Operating manual Fynn Xtra 4) The closing force can be adjusted by loosening or tightening the threaded bolt (1). Fig. 58: Position B 10.5 Tensioning/relaxing the door spring 1) First the cover must be removed and the side clad- ding detached.
  • Page 47: Adjusting The Turntable

    Operating manual Fynn Xtra 10 | Settings 10.6 Adjusting the turntable This turntable can be operated even with the firebox doors closed. If the turntable’s control lever is raised, then the turntable is unlocked and the stove can be turned. If on the other hand...
  • Page 48: Commissioning

    11 | Commissioning Operating manual Fynn Xtra Commissioning 11.1 Initial Commissioning NOTICE During the initial commissioning and in the following 2-3 combustion cycles, only approx. 2/3 of the maximum fuel quantity is to be used. NOTICE To avoid damage you must NEVER operate your Stove a greater quantity of fuel than that specified in this manual! During the first 3-4 combustion cycles at nominal heat output, odors may develop.
  • Page 49: Operation

    Operating manual Fynn Xtra 12 | Operation Operation 12.1 Before heating up The stove can only function properly if there is sufficient combustion air coming to the room of installa- tion (the appliance), specially if several firing installations are being operated at the same time. Ensure sufficient air supply before heating up.
  • Page 50: Heating In The Transition Period

    12 | Operation Operating manual Fynn Xtra 7) Close the door. ð It is best to allow the first layer of wood to combust without altering the air damper setting. ð If only the bed of embers is left (no more flames), you can place another layer of log.
  • Page 51: Maintenance

    Operating manual Fynn Xtra 13 | Maintenance Maintenance Have the maintenance carried out by an Austroflamm dealer or an Austroflamm service engineer.
  • Page 52: Cleaning

    14 | Cleaning Operating manual Fynn Xtra Cleaning 14.1 Cleaning the stove, flue gas ducts and flue pipe The stove, the flue gas ducts and flues should be annually - possible even more often, e.g. • after the chimney has been cleaned •...
  • Page 53 Operating manual Fynn Xtra 14 | Cleaning 1) Open the door. 2) Raise the grate with the attached hook. Fig. 65: Raising the grate 3) Take the cover provided and use it to cover the ash box. 4) Turn the handle of the cover clockwise until the handle engages.
  • Page 54: Cleaning The Door Window

    During cleaning and maintenance, the glass must also be cleaned. If it is not regularly cleaned then the soot particles may end up being burned in. This makes regular maintenance all the more important. • We recommend cleaning the glass with our Austroflamm glass cleaner or a commercially available window cleaner.
  • Page 55: Help

    Operating manual Fynn Xtra 15 | Help Help Problem Cause Solution The glass window is sooty Insufficient draft from time to time (depending on use) the window must be cleaned with glass cleaner Clarification with chimney sweeper (poss. extend chimney/measure...
  • Page 56: Firebox Lining

    15 | Help Operating manual Fynn Xtra Problem Cause Solution Operating temperature not reached Bring stove to the operating temper- ature Sooting up of the window after 8- 10 hours of fires is normal Chimney draft too low Contact chimney sweep 15.1 Firebox lining...
  • Page 57: Accessories

    Operating manual Fynn Xtra 16 | Accessories Accessories Have defective parts (accessories, spare parts) replaced by your specialist stove dealer. This guaran- tees that stove is and remains safe and functional.
  • Page 58 16 | Accessories Operating manual Fynn Xtra Item no. Quantity Article Article no. FYNN Xtra 2.0 basic appliance 071101 Steel front, top, complete 071002-29 Glass front, top, complete 071003 Ceramic front, top, complete 071004 Turntable set, complete, dm150 059007 Connecting set dm150 f RLU...
  • Page 59: Spare Parts

    Operating manual Fynn Xtra 17 | Spare parts Spare parts Spare parts can be ordered through our dealers. For ordering spare parts, it is necessary to provide the type plate picture or data from the type plate of your stove. This guarantees proper spare parts for your specific stove.
  • Page 60: Disassembling

    18 | Disassembling Operating manual Fynn Xtra Disassembling For correct uninstallation and dismantling of the stove, contact your Austroflamm specialist dealer. 18.1 Removing side cladding 1) Remove cover. Fig. 68: Removing the cover 2) Loosen the screws of the front top trim and detach trim.
  • Page 61 Operating manual Fynn Xtra 18 | Disassembling 3) Open door and detach bottom trim. Fig. 70: Open the door 4) Loosen the marked screws left and right. Fig. 71: Undoing the screws 5) Lift up and detach the side cladding. Fig. 72: Detaching the side cladding...
  • Page 62: Disposal

    NOTICE For correct uninstallation and dismantling of the stove, contact your Austroflamm specialist dealer. Electric and electronic components Remove the electric and electronic components from the appliance by dismounting them. These com- ponents must not be disposed of via non-recyclable waste.
  • Page 63 Operating manual Fynn Xtra 19 | Disposal Handles and decorative elements made of metal If present, disassemble or remove handles and decorative elements made of metal and dispose of as metal scrap. Local disposal options must be observed.
  • Page 64: Guarantee / Warranty

    For the replaceability of the warranty case the start-up log must be received by Austroflamm within one month at the latest of the initial commissioning. In or- der to make a claim on the warranty, repairs to your stove must only be carried out by a service en- gineer authorized by Austroflamm.
  • Page 65: Start-Up Log

    Operating manual Fynn Xtra 21 | Start-up log Start-up log Operator / Customer Dealer / Engineer Name Company Street Street Town and postal code Town and postal code Telephone Telephone Email Email Stove Working Comments Model Serial number Technology Visuals...
  • Page 66: Service Report

    22 | Service Report Operating manual Fynn Xtra Service Report Date Technicians Notes Work carried out, replacement parts installed...
  • Page 67 Operating manual Fynn Xtra 22 | Service Report Date Technicians Notes Work carried out, replacement parts installed...
  • Page 68 Notizen / notes / appunti / remarques...