Site Preparation; Environmental Eonsiderations - Wang DW/OS-20 Maintenance Manual

Daisy printer
Table of Contents

Advertisement

3305
CHAPTER 4
INSTALLATION
The installation instructions contained herein cover operational site
requirements and preparation of the equipment
through
initial
operational
checkout.
4.1
SITE PREPARATION
a.
Ensure that the correct ac power outlet is available at the site
connected to either 115 Vac
(+:..o,
-15%) at 60Hz or 230Vac (+10,
-15%) at 50Hz power •
b.
The main power cable requires a grounded three prong receptacle.
c.
The
printer must be
located within 6.5
ft.
of
the
a.c.
power
receptacle.
d.
The printer is a desk-top (table) model.
Choose an adequate piece
of furniture (see specification in Chapter 1).
4.2
ENVIRONMENTAL CONSIDERATIONS
The recommended ambient
temperature for the printer is 15°c to 28°C
(60°F to
80°F).
Temperature control
is
an
important
factor
because
the
printer is cooled by the surrounding room air.
If the system is situated in
direct sunlight,
there should be a shading device available to eliminate
excessive heat.
The recommended ambient relative humidity should be maintained between
40%-60%.
Normal precautions should be taken to keep dust, dirt, and other foreign
matter out of the printer.
The amount of contamination typically found in the
air in a normal business environment will not interfere with the operation of
the equipment.
Static electricity can interfere with operation of the printer.
It
can
be minimized or eliminated either by not installing printer in a carpeted
area, removing the carpeting from the area the printer is to be installed in
or by treatment of the carpet with an anti-static spray.
Additionally, for
new
installations
select
furniture
with
anti-static
upholstery
and metal
wheels, and maintain room humidity at about 40% (particularly during winter
months) to control static electricity •