REC - SETUP - KeyRnge [Key Range]
A new Map parameter is provided at Knob 2. This parameter selects the method used to
map newly recorded samples: either manual or auto.
If you select manual, you can then use Knob 3 to set the original key, and Knobs 4 and 5
to set the low and high keys. Note that the low and high key values can now also be set
to =Orig (sample's original key). To set the low value to =Orig, turn Knob 4 all the way
to the left. To set the high value to =Orig, turn Knob 5 all the way to the right.
If you select auto, you can then use Knob 3 to set the original key. The A3000 then
automatically sets both the high and low keys equivalent to the original key, so that the
range consists of a single note.
If you record a series of samples under the auto setting, the A3000 automatically maps
the samples to successively higher keys on the keyboard. Use Knob 4 to select whether
samples are mapped to white keys only (white), or to all keys (all).
REC - EFFECT - In&Out1, In&Out2
Version 1's In&Out page has been renamed In&Out1, and a new In&Out2 page has been
added.
You can use the new page to set the width for each recording effect.
Knob 3 sets the effect's width (stereo expanse).
REC - MONITOR - Monitor
The A3000 now retains the Monitor setting (at Knob 5) in nonvolatile memory, so that
the value is no longer lost at power-off.