Please read this Owner’s Manual carefully before operation and retain it for future reference. If you have lost the Owner's Manual, please contact the local agent or visit www.gree.com or send an email to global@cn.gree.com for the electronic version. NOTE: Actual product may be different from graphics, please refer to actual products.
Page 3
Explanation of Symbols WARNING This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to CAUTION property. Indicates important but not hazard-related information, used NOTICE to indicate risk of property damage. Exception Clauses Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons.
Page 4
The refrigerant This appliance is not intended for use by persons Before install the Appliance filled (including children) with reduced physical, sensory appliance, read with flammable or mental capabilities, or lack of experience an d the installation gas R32. knowledge, unless they have been given superv- manual first.
Page 5
Safety operation of flammable refrigerant Installation notes Check whether there is fire source or potential fire source in the maintenance area. The air conditioner must be installed in a room - The naked flame is prohibited in the mainte- that is larger than the minimum room area. The nance area;...
Safety precautions WARNING Installation Installation or maintenance The grounding resistance must be performed by qua- should comply with nation- lified professionals. al electric safety regula- The appliance shall be in- tions. stalled in accordance with Air Conditioner should be national wiring regulations. properly grounded.
Page 7
Safety precautions CAUTION Installation Instructions for installation For the air conditioner with- and use of this product are out plug, a circuit breaker provided by the manufac- must be installed in the turer. line. Select a location which is The yellow-green wire in out of reach for children air conditioner is ground- and far away from animals...
Page 8
Safety precautions WARNING Operation and Maintenance tioner to multi-purpose soc- This appliance can be used ket. Otherwise, it may cau- by children aged from 8 se fire hazard. years and above and per- Do disconnect power supp- sons with reduced physi- ly when cleaning air condi- cal, sensory or mental ca- tioner.
Page 9
Safety precautions CAUTION Operation and Maintenance frequently. Do not spill water on the re- Air conditioner gives off mote controller, otherwise burning smell. the remote controller may Indoor unit is leaking. be broken. Do not use fire or hair dry- er to dry the filter to avoid deformation or fire hazard.
Installation notice WARNING sure that the unit is running in cooling mode. Then, fully close the valve at high pressure side (liquid valve). About 30-40 seconds later, fully close the valve at low pressure side (gas valve), immediately stop the unit and disconnect power.
Page 11
Selection of installation location Requirements for electric connection Basic requirement 7.If the supply cord is damaged, it must be repla- Installing the unit in the following places may cau- ced by the manufacturer, its service agent or se malfunction. If it is unavoidable, please consu- similarly qualified persons in order to avoid a lt the local dealer: hazard .
Installation of indoor unit NOTE Indoor outdoor ● Pay attention to dust prevention Step 1: sures when opening the hole. Choose installation location Φ55 5-10 Φ70 Recommend the installation location to the client and then confirm it with the client. Step 2: Step 4: Install wall-mounting frame...
Page 13
Tightening torque (N . m) drain hose Hex nut diameter 1/4'' 15~20 3/8'' 30~40 1/2'' 45~55 insulating pipe 5/8'' 60~65 NOTE 3/4'' 70~75 ● Add insulating pipe in the indoor drain hose in order to prevent condensation. ● The plastic expansion particles are not provided. Wrap the indoor pipe and joint of connection pipe with insulating pipe, and then wrap it Step 7:...
Page 14
drain hose connection pipe Remove the wire clip; connect the power conn- band ection wire to the wiring terminal according to the color; tighten the screw and then fix the po- wer connection wire with wire clip. 07K、09K indoor power cord GWH12AGB-K6DNA1A GWH12AGB-K6DNA4A Bind them evenly.
Clean and maintenance WARNING ■ The filter should be cleaned every three months . If there is much dust in the operation environme- WARNING nt, clean frequency can be increased. ■ Turn off the air conditioner and disconnect the ■ After removing the filter, do not touch fins to power before cleaning the air conditioner to av- avoid injury.
Checked items before maintenance Phenomenon Solution Check items General phenomenon analysis Whether there’s od- Eliminate the odour Odours are our source, such as Please check below ite ms before asking for source. Clean the furniture and cigare- emitted filter. maintenance. If the malfunction still can’t be tte, etc.
Parts name Indoor Unit air inlet panel filter aux. button panel upper air guide louver air outlet lower air guide louver ■ If remote controller is lost or damaged, please use aux. button to turn on or turn off the air conditioner.
Operation and introduction of remote controller Introduction for icons on display Buttons on remote controller screen I feel Set fan speed Turbo mode Send signal Auto mode Cool mode Dry mode Fan mode Heat mode Sleep mode 8℃ heating function Power limiting operation Health mode ON/OFF...
Page 19
Introduction for buttons on adjust fan blowing angle. remote controller When selecting heating mode, the air condition- er operates under heat mode. Press " " or " " NOTE button to adjust set temperature. Press "FAN" ● This is a general use remote controller. It could be button to adjust fan speed.
Page 20
turn to quick COOL or quick HEAT mode. " " ically swing up & down at maximum angle. icon is displayed on remote controller. Press this ● When selecting " " , air condition- 、 、 、 、 button again to exit turbo function and " "...
Page 21
Sleep, circulate between these, after electrified, NOTE Sleep Cancel is defaulted. Under on and off status, you can set T-OFF or T-ON Sleep 1 is Sleep mode 1, in Cool modes; sleep simultaneously. status after run for one hour, the main unit setting Before setting T-ON or T-OFF, please adjust the clock time.
Page 22
Function introduction for WiFi combination buttons Press " WiFi " button to turn on WiFi function, "WiFi " icon will be displayed on the remote controller; Energy-saving function Hold " WiFi " button for 5s to turn off WiFi function and "...
Page 23
When the remote controller is turned off, power ● Child lock function limiting function is cancelled. If you want to acti- vatethe function, please repress this button. Press " " and " " simultaneously to turn on or If the current power is lower than the maximum ●...
Test and operation Check after installation ● Check according to the following requirement after finishing installation. Items to be checked Possible malfunction Has the unit been The unit may drop, shake or installed firmly? emit noise. It may cause insufficient Have you done the refri- cooling(heating) capacity.
Configuration of connection pipe Additional refrigerant charging amount for R32 Standard length of connection pipe: 5m, 7.5m, Min. length of connection pipe. For the unit with standard connection pipe of 5m, there is no limitation for the min length of con- nection pipe.
Page 26
B: Remove the burrs smooth surface Remove the burrs with shaper and prevent the ● burrs from getting into the pipe. improper expanding pipe shaper leaning damaged crack uneven surface thickness downwards the length is equal Working temperature range Indoor side Outdoor side DB/WB(°C) DB/WB(°C)
Specialist’s Manual The following checks shall be applied to instal- fire extinguishing equipment shall be available to ● lations using flammable refrigerants: hand. Have a dry powder or CO fire extinguisher adjacent to the charging area. – the charge size is in accordance with the room size within which the refrigerant containing parts are in- Ventilated area ●...
Page 28
Specialist’s Manual Repair to intrinsically safe components – recovery equipment and cylinders conform to ● the appropriate standards. Do not apply any permanent inductive or capaci- d) Pump down refrigerant system, if possible. tance loads to the circuit without ensuring that this e) If a vacuum is not possible, make a manifold so will not exceed the permissible voltage and current that refrigerant can be removed from various parts...
Page 29
Specialist’s Manual dition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery mac- hine, check that it is in satisfactory working order, has been properly maintained and that any associ- ated electrical components are sealed to prevent ignition in the event of a refrigerant release.
Page 30
GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: global@cn.gree.com Web: www.gree.com 600005062912...
Need help?
Do you have a question about the GWH07AGA-K6DNA1A/I and is the answer not in the manual?